You are a great teacher👏🏻👏🏻👏🏻👏🏻 I like your all videos. Learned lot of things from you about refrigeration and air condition. You explained very good. Thank you so much.👍👍👍 God bless you.❤️❤️❤️❤️❤️❤️❤️❤️
Sir Ji Great Detailed Videos. Thanks For This Great Information......am from Qatar just Bcoz of Ur updated videos am getting salary increment rite away
Sir i have a small suggestion for ,u can add air conditioner in ur channel name so that people get recommendations of ur channel when they search regarding air conditioner. And u get lots of views drom world wide which will help u both manners. And enable captions availability. Your knowledge is mass and people shud take a proper use. Thank you
Compressor jab refrigerant ko compress krta hai to uska pressure aur temperature dono badhta hai. Agr hum compressor ka temperature measure krna chahe to kaise krenge? Kis instrument se hum compressor ka temperature measure krenge? Aur kya hum compressor k temperature ko manage ya control kr skte hai? Plz answer.
Sir AC jis company Ka hai wo thermostate kaam Nahi Kar Raha to honywell thermostate lagakar AC k pcb circuit KO hata Diya Jaye to indoor coil sensor Ka v connection hat jayga. Aur Honeywell thermostat Ka indoor fan mood na on Karke only compressor chalaya Jaye to kya hoga please reply please bahut confusion hai ispe kyuke LP hp switch to pressure KO sense karega aur indoor Ka fan Nahi chalega to evaporation Nahi ho payga aur low temperature Ka liquid refrigerant compressor pe jayga to kya aisa Karna Sahi hai kya safe hai ya aisa bilkul v Nahi Karna chahye please bataye
Hello Sir,sir kuch log outdoor ki discharge line ke sath filter dryer ke agay capillary tube lga dete hein...kya aisa krna theek rehta hei...?cooling main koi fark to nhe parta...? thanks for ur best ever videos
Sir agar hum condensor par fan side se pani ki halki halki bochar karke condensor ko jaldi thanda karen to kya room bhi jaldi thanda hoga or kya bijlj ki bhi bachat hogi?
Sir you are explaining very well I have bought a new ac last week non inverter onida ac...i heard that we should not maintain 30 or 29 degrees in indoor...only from 28 we must start..is it true.. please reply
At condenser outlet temp is 40°C and at evaporator inlet temp is 4.4°C . The difference of 40 and 4.4 is due to heat transfer in capillary to atmosphere?
Sir Mera name Hemraj kumawat h me Jaipur ka rhne wala hu me aap ke sare video dekhta hu But muje aap se kuch puchna h Mera saval h AHU kya h ye kese work karta h Thanku sir🙏
Sir,please do videos on ADP,DPT,refrigeration system COLD ROOM heat load calculations,ammonia refrigeration system ,its pressure and temperature chart,and it's related topics ..
I am indian Good Evening Sir i am work at saudi arbia your vedio is all helpfull plz sir ac me jo oil padta hai ye kahe ka hota hai or iska name kya hai plz sujest me
If by any means we bring temp. of refrigerant to 20°C or below instead of 40°C at the entry of drier, will it be harmful or beneficial ? Pls clerify. Am not a professional.
Heat khichne ke baad vo vapour ho jata hai, vapour fir heat ko absorb nahi kar sakta hai vapour ko liquid main convert karne ke liye usse compress kar ke condenser main bhejte hai
Sir A/c me gas R22 65to 70psi hai aur air flow indoor outdoor dhono achcha hai Lekin cooling nahi hai kya reason hoga aur iska solution. please sir. Thank you.
Sir I have a little confusion.we use a single refrigerant in whole system.As I am observing saturation temperature of refrigerant in condenser is 40° c and in evaporator it is 4.4°c .How it is possible the refrigerant on 40°c in subcooled and same refrigerant greater than 4.4°c will be super heated?Plz sir solve my confusion.
Kya baat hai. Nyce knowledge. Boht saare concept aaj clear hue Hein. Excellent 👍👌
Welcome
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
Apke video Alp ke liye bhut Shi h
AP ese please bnate rhiye
Apko sir Dil se danhyawad
R .a.c. poora clear ho rha h
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
You are a great teacher👏🏻👏🏻👏🏻👏🏻
I like your all videos. Learned lot of things from you about refrigeration and air condition. You explained very good. Thank you so much.👍👍👍
God bless you.❤️❤️❤️❤️❤️❤️❤️❤️
Welcome
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
Lot of respect sir for spreading such deep knowledge. Thanks a lot. From pakistan.
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
Shinde Ji your explanation is superb , I am also in heating and air conditioning servicing
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
YOU.ARE.GOOD.STUDY.&GOOD.KNOWLEDGE.VERY.NICE
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
Nice video sir, nice information sir.....
Welcome
Nice video sir....bunch of knowledge in 10min...thanku sir..
Please make video of how deep.frezzer works
Thanks
Thank you very much sir.
Your explanation is very well we are learning from you many things.i am from Pakistan # ###🇵🇰####🇮🇳###.
Thanks
Ekch number sir......duct design ek video banva sir
Ok
Explanation of topic is good .keep it up .
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
Good information 🙏🏻🙏🏻🙏🏻sir ji 😎
Awesome sir AAP say buhat kuch sikc Ney milahey thank you .sir main hp LP control differential or range k barey main knowledge provide kejiya sir .
Bohot acchhi jankari mili.
Thanks u very much sir ap se bahut kuch sikhne milraha raha .
Thanks
Sir aap ka samjhane ka terika bhut grat hai
Great information sir ji 👍
Thanks
Sir Ji Great Detailed Videos. Thanks For This Great Information......am from Qatar just Bcoz of Ur updated videos am getting salary increment rite away
That was my question which i asked u..
Thank you
Welcome
Very good Sir lot's thanks
Sir AAP great ho....
Sir refrigerant ka theory ke upor video upload kijya please sir
Ok
Great Girish Boss
Thank you this video is very powerful in my life
Welcome
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
Great work done by u sir
Thanks
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
sirji vrry usefule vdo.
plz make a vdo on how to charge the system wid diffrent types of refrigrents and precautions to be taken.
Ok
Thanks sir
Chiller par bhi aiasi hi video banayen deeply information k sath
Jarur
Sir i have a small suggestion for ,u can add air conditioner in ur channel name so that people get recommendations of ur channel when they search regarding air conditioner. And u get lots of views drom world wide which will help u both manners. And enable captions availability. Your knowledge is mass and people shud take a proper use. Thank you
Thanks for Suggestions I will to implement it
useful information
Thanks for u r video's sir...
Really awesome
Sir pls can u make a video on air conditioning control systems
Super nice sir ji video
Thanks
Compressor jab refrigerant ko compress krta hai to uska pressure aur temperature dono badhta hai. Agr hum compressor ka temperature measure krna chahe to kaise krenge? Kis instrument se hum compressor ka temperature measure krenge? Aur kya hum compressor k temperature ko manage ya control kr skte hai? Plz answer.
Sir very useful video sir, of course all videos very knowledgeable sir. Sir please can you make video about the Ammonia Refrigeration system
Ok
U are great man
Sir AC jis company Ka hai wo thermostate kaam Nahi Kar Raha to honywell thermostate lagakar AC k pcb circuit KO hata Diya Jaye to indoor coil sensor Ka v connection hat jayga.
Aur Honeywell thermostat Ka indoor fan mood na on Karke only compressor chalaya Jaye to kya hoga please reply please bahut confusion hai ispe kyuke LP hp switch to pressure KO sense karega aur indoor Ka fan Nahi chalega to evaporation Nahi ho payga aur low temperature Ka liquid refrigerant compressor pe jayga to kya aisa Karna Sahi hai kya safe hai ya aisa bilkul v Nahi Karna chahye please bataye
Hello Sir,sir kuch log outdoor ki discharge line ke sath filter dryer ke agay capillary tube lga dete hein...kya aisa krna theek rehta hei...?cooling main koi fark to nhe parta...? thanks for ur best ever videos
Cooling pe jarur asar padta hai
+Girish Shinde sir cooling km ho jati hei ya usmein kmi ho jati hei
Nice video 📹 sir g..
Thanks
Sukriya ....
Very.NICE.GOOD.KNOWLEDGE
thanks
Thank you so much sir very nice details information 👌👍 but I have a question these refrigerant pressures are for only AC or fridge and freezer also???
These pressure are only for air conditioner
Thanks sir
Hiii sir could you please make a video for walk-in chillar and freezer with full gas pressure and how it's defrost ,🙏🙏🙏
Sir Volume Ko Increase kariya To Zyada Achhe Se Samajh Aayega🙏🙏
Very Nice Sirji..
Thanks
Very nice video sir
Sir! Cold room pe bhi video bnaiye
Sir agar hum condensor par fan side se pani ki halki halki bochar karke condensor ko jaldi thanda karen to kya room bhi jaldi thanda hoga or kya bijlj ki bhi bachat hogi?
Ho sakta hai
@@girishshinde kya aap pakka nahi ho ke esa ho sakta hai ke nahi
Nice , ideal Super heat aur sub cooling kitna hona chahiye
In refrigerant oil will be mix what happen to chiller and how to remove it..? plz plz reply me sir..
Sir very good vedio
Good👍
Sir hm koi split ac lgate hain to uski pipe line maximum kitani lambi kr skte hain plz suggest
Sir you are explaining very well
I have bought a new ac last week non inverter onida ac...i heard that we should not maintain 30 or 29 degrees in indoor...only from 28 we must start..is it true.. please reply
Sir temperature ke Saath teeno pressure bhi badal Sakta hi kya ( suction pressure, discharge pressure,aur standing pressure,)
Yes
Supperb sir🙏🙏🙏
Thanks
At condenser outlet temp is 40°C and at evaporator inlet temp is 4.4°C . The difference of 40 and 4.4 is due to heat transfer in capillary to atmosphere?
ruclips.net/video/KQEh6t7pdCw/видео.htmlsi=tgz4KfQVEHpoV6FJ
Very good
Thanks
Very good video
Namste sir ek interview me mujhse puchha Gaya ki grill temperature Kya hota hai or kitna hota hai .pls one vedio
Good informasen
Thanks sir nice video
very very good
Thanks
Wow
Nice sir thank you so much for this, sir temperature stable rakh kar humidity chang karne ya mentain karne k liye kya karna hoga plz bataye sir
Humidifier ya dehumidifier lagwana hoga
Hii sir,
Very informative,sir i need to understand what is net refrigeration effect??
Ok I will make video on that
@@girishshinde thanks sir...
Sir
Mera name Hemraj kumawat h me Jaipur ka rhne wala hu
me aap ke sare video dekhta hu
But muje aap se kuch puchna h
Mera saval h AHU kya h ye kese work karta h
Thanku sir🙏
Mera AHU ka video dekho
NYC vedeo Sir
Sr.deep freezer ma kis rarah capillary tub set karna chahie
Deep freezer data kar ke mera ek video hai check kar lijiye
Thank you sir god bless you
Good information sr
Thanks
Sir thanks to upload this video.
Sir I want to know chiller palant suction line & discharge line pressure .pleace reply me .
Sir,please do videos on ADP,DPT,refrigeration system COLD ROOM heat load calculations,ammonia refrigeration system ,its pressure and temperature chart,and it's related topics ..
Ok
@@girishshinde thank u sir
Mr.girish shinde can u explain the PRESSURE ENTHALPY &
TEMP ENTROPY VCRC
Yes
Sir. ....1 ton ke system me compresser 1 minute me kinti kg refrigerant vapour ko compress krta h?????
Refrigerant ka naam batana, isse hum mass flow rate kehte hai, har refrigerant ka mass flow rate alag hota hai
R-22
@@AmanKumar-uc2gr 236 kj/sec
@@hotsundad1321 sir 236 kj/sec
To compressor heat deta h refrigerant ko
Sir please make a video for discharge and Standing pressure gas and oile and how can we check
ok
Good jop sir
Thanks
@@girishshinde sir drain line me u trip kiyu banate hai
I am indian Good Evening Sir i am work at saudi arbia your vedio is all helpfull plz sir ac me jo oil padta hai ye kahe ka hota hai or iska name kya hai plz sujest me
Ac mineral oil or POE,PAG oil use hota hai
शिंदे सर 1 टन के कॉम्रेसर मे थर्मोस्टेट वाल नही लगा ते क्य ? और लगाना ही है तो कोणास लगाना चाहीये।
Capillary tube
Sir mera ac me suction preasuse 150 psi aa raha h (r32). Kya yeh normal h?
SIR 600A Ka suction pressure 0-1 PSIG hai na..I am confused
Refrigerator aur air conditioner ka suction pressure alag alag hota hai
1.5 ton ac R32 suction pressure 140psi aur ac grill temperature 14℃. ok hai kya?
Not ok
@@manish.pandey toh kitna chahiye
Grill temperature must be below 10 after 15 mins of run in low fan speed
verry nice
Hi Kiran, How r you?
Sir, Split AC me Nuwton or phase dono par current aa rha ho to kya kre
sar fridge ka kitna liter ma kitna compsser laganaha kitna size ka kapelare laganaha
Sir compresar ke oil ka kse pta chalega ki kam h ya nhi
thank you a lot . sir
Welcome
Sir ji suction pressure ko running pressure bolte he ???
Ji ha
Sir daikin vrv ki setting pr vedeos banao
thanku sir
If by any means we bring temp. of refrigerant to 20°C or below instead of 40°C at the entry of drier, will it be harmful or beneficial ? Pls clerify. Am not a professional.
Dear sir I'm Mohammad Arman refrigerat 600a which air conditioners me use hoti hai sir
Window ac
@@girishshinde sir thanks u very much
Konsi refrigerant use huva h ji es me
Refrigerant koi bhi air conditioner ka temperature same hota hai
Sir previous lecture u told refrigent in shell side in condenser. But now u e showing refrigent in tube in condenser.
Sir ji thanks
Welcome
Sir mera question ye hai ki r22 refrigerant ka temperature kitna hota hai condensor mein
Sir super heat ke liye temperature capillary se pehle le capillary ke bad ka
Sir hame refrigent ko compress, veporigation condensation kyu karna pdta hai kyu jab e itna already cooking hota -26. 8
Heat khichne ke baad vo vapour ho jata hai, vapour fir heat ko absorb nahi kar sakta hai vapour ko liquid main convert karne ke liye usse compress kar ke condenser main bhejte hai
I want to know that what is the temperature of compressor's body
sir ji compressor ke type ke baare me batayiye
How to find out suction pressure and discharge pressure?
By connecting pressure gauges to system
Sir A/c me gas R22 65to 70psi hai aur air flow indoor outdoor dhono achcha hai Lekin cooling nahi hai kya reason hoga aur iska solution. please sir. Thank you.
Sir I have a little confusion.we use a single refrigerant in whole system.As I am observing saturation temperature of refrigerant in condenser is 40° c and in evaporator it is 4.4°c .How it is possible the refrigerant on 40°c in subcooled and same refrigerant greater than 4.4°c will be super heated?Plz sir solve my confusion.
Hello sir ek Simi siled compressor hai jis ka gas R12 hai us me R134 use kar sakte hai kiya..
V.380/440 .5 Ton
Nahi
Capalliry 10 fit ke jagah 6ya 7 fit laga to kya hoga?