थर्मास्टाटिक एक्सपांशन वाल्व l Thermostatic Expansion Valve l
HTML-код
- Опубликовано: 7 фев 2025
- This video will explain you working of thermostatic expansion valve in simple Hindi
#girishshinde #airconditioning
Mail Id - girishsshinde@gmail.com
Click on following link for A Text book for All four Semester Mechanic Refrigeration and Air conditioning (I.T.I). It includes all four semester syllabus as per NIMI - DGT pattern as well as Short Question Answers and Multiple Choice Questions. Book Language English.
amzn.to/2HhPwcv
Click on following link for RAC I.T.I Multiple choice question answer and old solved question papers
www.amazon.in/....
रेल्वे असिस्टेंस लोको पायलट एवं तकनीशियन परीक्षा की तयारी के लिए हिंदी बुक पाने के लिए निचे दिए गए लिंक पर क्लिक कीजिये
www.amazon.in/....
I.T.I रेफ्रिजरेशन एयर कंडीशनिंग हिंदी प्रैक्टिकल बुक के लिए निचे दिए गए लिंक पे क्लिक कीजिये www.amazon.in/....
I.T.I रेफ्रिजरेशन एयर कंडीशनिंग हिंदी प्रैक्टिकल बुक के लिए निचे दिए गए लिंक पे क्लिक कीजिये
www.amazon.in/....
Thanks guru g you tube pe aap se achha koi bhi nahi he jo HVAC ke bare bataye mene sir aap ke sare video lagbhag dekhe sir me mechanical RAC engg. Diploma ka student hu many many thank you guru g
Welcome
Guru ji
Ap kya jwab nhi hai pdhane ka
Apke charno mai mera parnam swikar karen
bahut badia jankari de sir g
sir gaddi ke expeshen vaal kaise kaam krta hai plz ek vedio bnao g
100 Million like explain in a way can understand easily
sir ap ke video bhot ache he
Thanks
Very nice 👍
Jabardast .
Thanks
Thanks sir ji
Bhut achhi tarike se smjate h sir ap
Welcome
Finally im cleared about TXV working principal. Nice and simple explanation. Thanks you sir
Good job sir
Thanks
Sir your explain awesome
Thanks
Very helpful vedio
Thanks you sir ❤️
Well done sir
Nice explained
Thanks
Good explanation 👍
Sir mujhe aap ke videos acche lagte hai
Really great work thanks sir
Acha samjha sir good
Thanks
Txv Wala video excellent sir ji
Thanks share this video with your friends
excellent explanation
Sir your way of explanation is best 🙏🙏
बहुत ही सुंदर और आसानी से समझ आ जाये ऐसे वीडियो बनाने के लिए तहे दिल से आपका धन्यवाद, और इसके खराब होने के कारण ओर पहचान कैसे करें कि ये खराब हो गया है इस पर भी हमारा मार्ग दर्शन करे श्री मान
nice video sir
Thanks
Excellent video Sir
Thanks
Super sir👌👌👌👍
Very nice video sir
Maja aagay bhai kya valve aisa valve toh biology Mai tha 😅
Very nice
Finally u made me understand TEV
Thank u sir
Welcome Sameer ji
Sir very big thanks
Welcome
अच्छा है
Good
Thanks
Nice video
Thanks
@@girishshinde sir aeroplane ✈ me cooling system kaise kaam karta hai aur kya refrigerant use karte hain ya fir wo kaise work karta hai .. Espar ek video banaye
It's help who is unknown from this..
Thank you
very nice sir. ..
Good sir
You my friend are what people call a real gem!
Nyc sir
Thanks
Hi sir what is VFD why use ? please explain details sir thanks sir
supper explain
Thank you from Pakistan
GREAT
Thank you Sir very nice video..
always your videos become nice
good evng sir g and namaste
Nice sir and thanks
السلام علیکم و رحمت اللہ و برکاتہ
جزاک اللہ خیرا
Thanks you sir you all videos are very very informative
May Allah bless you.
With right fath
so nice
Nice
Girish Bhai aapne internal eq k baare me nahi bataya mujhe wohi jaanna tha
Sir yeh kaise patah kra ke kis system mein konse valve set kra ya koi bhi set kr skta hai
nice
Thanks
Thanks
Nice vidio
Sukriya sir ......
Thanks
Sir nice vidio hi ASA koni nay shikvat tumcha sarka chan trening
Sir apki chennel bhut searching kiya
Thanks
Thanks
Welcome
Nice sir, pls make video on fire tube boiler
Sir electrical expansion value ke bare me video banaiye
Thanks sir chillar ka wiring panel box ke bare me bataiye sir
ROTO LOCK VALVE POSITION KA VIDEO EXPLANATION K SATH PROVIDE KIJIYE SIR .
Thanks sir
Super sir
internal equalizer or external equilizer ki working same hoti he kia sir??
Nahi
Power element ko laft or right side me down krke installed kre ya niche krke aur stem (spring) upar krke installation kre to kya problem ho sakta hai.
sir thanks for this video
Welcome
Ek sawal hai mera jab valve close ho jayega to refrigeration cycle to break ho jayega
Please explain
100% close nahi hota
thanks sar
Pranam sir
Awesome explanation .
Thanks lot.
Instablaster
sir p1 pressure jub km hojata hy to txv pora band hojata he ya nh ?
Possible
Thank you sir
Welcome
Very nice and detailed explanation, Sir plz make like such video on Air Cooled Chiller also, thanks
AHU ka ek vedio baney na sir plz
Ok
@@girishshinde thanks sir jii
@@girishshinde full details May sir jii
Make a video of Double door refrigerator evaporator
train ki ac coach mai 3.5ton ka compressor lagta hai to usmey sir g condenser coil mai kitna degree hit rehta hai aur uska psig kitna rahega
Sir aapne kaha high pressure and high temperature ka liquid refrigerant expansion valve me enter karta hai to kya condenser bagair temperature kam kiye refrigerant ko liquid me convert karta hai agar ha to plz bataye kaise agar na to phir jawab kya hai
Condenser ke inlet main 95 degrees Celsius temperature hota hai aur out let main 40 degrees Celsius hota hai matlab condenser temperature kam karta hai lekin evaporator ke mukable yaha temperature jada hai iss liye usse high pressure high temperature liquid kehte hai
Ok Thank you very much sir but ye bataye condenser outlet se liquid refrigerant ho kar k hi nikalta hai na ya vapour form me huta hai plz is confusion ko bhi door kardo sir
thanks a lot sir... sir plz make a video about how we choose a compressor according to the refrigrant
Question no 1- 1.5 ton ki unit pe capillary k bad se cooling honi chaiye. Lekin main ne observe kiya hai ki capillary k bad se jo liquid line jati hai cooling coil k liye us line pe jyada thanda nahi hota hai direct cooling coil se thanda chalu hota hai esa kyun jab ki capillary outdoor main lagi rehti hai?
Question no 2 - TXV mein internal equaliser line ko hot gas bypass k liye istemal kar sakte hain kiya in big units?
Equalizer line bhi ek video banay Aap.
Sir .
Feelar bulb me kosni gas hoti hai
Q k
Koi sa b gas ho refrigeration me is ka presar badhega to tempreture badhega .
But
Feelar bulb me konsi gas hoti hai
Jb cooling aajati hai room me to section tempretur km hojata hai
Like 48 f
Us time feelar bulb ki gas km hojati hai
Aut jb
56 ya 58 f hota hai tempreture cooling out ka
Tb feelar bulb ka presar badh jata hai. Aur expansion full open hojata hai
Sir
48 f ' se 56ya58 f tepmreture me itni jaldi sance karta hai feelar bulb . Konsi hai isme gas feelar bulb me
Jo gas system main hoti hai same gas feeler bulb main hoti hai
Chilled water system
Sir,
Thermal.expansion valve k upar k side se 2 capilary line jati hai jo evaporator k suction line se attach hoti ek filler bulb k roop mai or dusri line sidhi evaporator line mai judi rehti hai
To sir ye filler bulb ye jo disri line hai iska kaam kya hota hai
M confused
Pls reply
Expension valve kitana voltage pe oporat hota sir please reply sir
Thanks for good explanation, but which refrigeration or gas filled in filler bulb plz reply..
सर अगर एक्सपेंशन वाल्व बहुत देर तक बंद रह गया तो कंप्रेशर तो चालू रहता है इस स्थिति में कंप्रेशर तो चालू ही रहता है जिससे कंडेंसर कॉइल पे एवं कंप्रेशर पर लोड आ जाएगा ।।। और कंप्रेशर डैमेज हो सकता है । इस स्थिति में क्या होता है
Expansion valve pura band nahi hota, jab expansion valve thida close hota hai tab compressor unload hota hai, aur kisi bhi part pe load nahi aata
Sir yeh select kaise kra ke kon sa system mein kon se valve select kra
Sir Chiller ka pura part ka video banakar samjhaie please sir
Sir hamara -52 ka lp hp screw compressor hai refrigerant r22 hai aur direct condensing unit hai, secondary refrigerant nahi hai , usme expansion valve nahi lage huve hai , lcv valve hai (liquid control valve)lp ka suction temp -50 milta hai , aur suction press -20 psi rehta hai , hum lcv ke baad hand expansion valve lagaye to kya change aayega , suction pressure kum ho sakta hai kya ?, Hamre compressor unload hoge ? ,
Sir arfes key barey mey kuch jankari dijyeh
Sir one. Tr expenson valve clear nut tayp usme oriphase kitne no. Ka lge ga
Watar chillar printing press
Sir best veodio but prectical me veodio banaye plz plz plz our samajh me aayega ham logo ko plzzzzz
Sir car ac system pe video banavo
sir package ac me expansion valve child hota hai ke hot please coment
Cool
TXV valve pe bahot jyada ice jam rha h sir kya kya Reason ho skta h
Block ho sakta hai
which gas or liquid used in filler bulb .
It may be liquid or vapour thats depend t upon temperature
Sir refrigerant cycle ka or kuch uske andar ke video gane dena sir Jessica Uske chote chote se parts ke baare mein
Sir,If power is not supplied to HVAC,.Is capillary tube sense or not suction line after that instructions given by power head to pin.is it possible???? Plz clarify that situation.
Sir internal equallaizar line ka bhi kaam karne ka ek video banaye plz
Hi sir,I have a question....if heat load is less,TXV Will reduce refrigerant flow rate.but what will be the refrigerant pressure after expansion?high or low???if it is low,then room will become more cooled na?????please reply.....tnx
If room becomes more cooled then cooling sensor will detect it and it will inform to compressor and compressor will stop.
Sir duct ka upar video banaye
Sir capillarytube ha video banaiye
Dear sir thank you for sharing knowledge I want to know more about p2 and p3 pressure .
Ok
As per my knowledge in txv one is internal equalizer line, and other is external equalizer line. In this my confusion is in equalizer line from suction refrigerant will flow or frm liquid line please please make a video for this confusion dear sir
Good evening sir
Expansion valve gas ko expand karta he kya
Plz