Complete manual calculation of RCC column design by using IS 456 2000 code | structural design |

Поделиться
HTML-код
  • Опубликовано: 29 авг 2024

Комментарии • 36

  • @basappab2983
    @basappab2983 2 года назад +1

    Super class sir & beam slab design videos upload sir tq.

  • @bvrbvr1351
    @bvrbvr1351 10 месяцев назад

    The span in between two columns 30 feet, 250tonnes comes on each column of five stored building, pl design size of column along with steel, further the soil is B. C soil, pile foundation to be designed for pile cap and piles along with steel.

  • @kameshvarverma5113
    @kameshvarverma5113 7 месяцев назад +1

    Thank you sir

  • @axatrathod
    @axatrathod 9 месяцев назад +1

    Great...sir👍🏼👍🏼

  • @mananabendramalakar6797
    @mananabendramalakar6797 Год назад

    It's good

  • @ehteshamansari2678
    @ehteshamansari2678 2 года назад

    while calculating the ASC why again we need the load formula however we can simply calculate with the help of small formula of relation between Ag=Ac+Asc.

  • @mukilmohan8665
    @mukilmohan8665 2 года назад +1

    Sir calculation of load in one column and beam of g+1 to g+5 building. Explain load calculation manual sir

    • @civilengineeringbyshravan9596
      @civilengineeringbyshravan9596  2 года назад +1

      Will upload soon

    • @mukilmohan8665
      @mukilmohan8665 2 года назад

      @@civilengineeringbyshravan9596 waiting sir and also upload the load transfer from slab to beam to column to footing manual calculation sir

    • @varshinivarshu773
      @varshinivarshu773 7 месяцев назад

      How did u get to know that ?? If so pls let me know

  • @Dharmendrayadav-ut7ts
    @Dharmendrayadav-ut7ts 2 года назад +1

    Excellent sir.. 👍..
    Can u tell me pls...how to see load for a building ....and where to see ..whether in is 456 or other?
    I have two residential building Projects g+1 and g+2 ..
    For How much load, should I design their column?..
    So, question is,
    How to calculate the amount of load coming on the building..?

    • @varshinivarshu773
      @varshinivarshu773 7 месяцев назад

      Same doubt, if u know that pls let me know

  • @abhi9239
    @abhi9239 3 месяца назад

    Sir if Length of Coloum is unknown then how will min. Eccentricity arrive

  • @abhijitkachare9194
    @abhijitkachare9194 2 года назад +1

    Sir can you please teach how to make Excell shits using this formulas , so that we don't have to calculate this every time

  • @vitthalgawade7448
    @vitthalgawade7448 2 года назад

    Sir give detail information during the example solving

  • @halalmeatshophk
    @halalmeatshophk Год назад +5

    wrong math calculation. A.g. result should be 168216.44

    • @halalmeatshophk
      @halalmeatshophk Год назад +2

      also in is-code 456 clause 39.3, it says that minimum eccentricity should not exceed 0.05D. If you choose D as 400mm, then 0.05D is equal 20.0 but your minimum eccentricity is 20.33 which is greater than 0.05D, so your analysis does not comply with clause 39.3
      regret to say but do you want to clarify ?

  • @tanmoypalit2377
    @tanmoypalit2377 3 месяца назад

    Is it in LSM or WLM method?

  • @LOGAN097
    @LOGAN097 2 месяца назад

    You designed column as rectangular but dimensions finded in square column (Assumption is wrong)

  • @Madhu-nb5zl
    @Madhu-nb5zl 2 года назад

    Sir plz tell is it under limit state method?

  • @perumal869
    @perumal869 2 года назад +1

    Sir ,all videos camera focus long not clear , your teaching speed so please slowing teaching

  • @kamrulislamkabbo6133
    @kamrulislamkabbo6133 2 года назад

    This short column or long column

  • @infinity..559
    @infinity..559 2 года назад +1

    How did you get 1200kn load??

  • @NehaNaaz-o6j
    @NehaNaaz-o6j 27 дней назад +1

    Letters not appearing

  • @jayabratasaha3451
    @jayabratasaha3451 11 месяцев назад

    sir how did you get the 256 mm c/c?

    • @satyakabaddi8422
      @satyakabaddi8422 8 месяцев назад

      Transverse reinforcement (pitch)
      1)16d=16*16=256mm
      2)Min lateral dimension of column 400mm
      3)300mm
      Least value taken out of these values ,that's why he took 256mm

  • @bvrbvr1351
    @bvrbvr1351 10 месяцев назад

    Pl design 250 tonnes on Colum.

  • @jyothiprakashpeelipram3103
    @jyothiprakashpeelipram3103 Год назад

    Ur notes has not seen. Please allow close up seen of notes.

  • @Busyguy1119
    @Busyguy1119 5 месяцев назад

    Aap ne pehla hi formula galat likha he bhai, not watching the video
    0.4fck aayega na ki 0.45,
    0.45 Khali axial load case me aayega