Autoclave Validation, Minimum and Maximum Load,

Поделиться
HTML-код
  • Опубликовано: 31 янв 2025

Комментарии • 31

  • @maheshpatel2206
    @maheshpatel2206 4 месяца назад +1

    Jaberjust

  • @shawezmalik6823
    @shawezmalik6823 Год назад +1

    Nice information sir thank you sir

  • @ravishankarmodi7492
    @ravishankarmodi7492 Год назад +1

    Sir the way u explain is very fantastic.... Thank u sir

  • @sumitkumarsharma3914
    @sumitkumarsharma3914 Год назад +1

    Thank u so much sir
    Very helpfull

  • @nirmalsartana4061
    @nirmalsartana4061 Год назад +1

    Nice information sir

  • @maheshgeergiri5606
    @maheshgeergiri5606 Год назад

    Great knowledge sir.

  • @kichootv
    @kichootv Год назад +1

    What is Minimum Load and Maximum Load in Autoclave? Why Required? @PHARMAVEN #aseptic #sterile

  • @shrikrishnakarnataki4876
    @shrikrishnakarnataki4876 5 месяцев назад

    Very nice! Please also state the importance of the number of pulsating vacuum applications being included in the validation protocol.

  • @bhupendrashukla1972
    @bhupendrashukla1972 Год назад

    Nice explanation...

  • @PharmGrow
    @PharmGrow Год назад +3

    Can we consider empty chamber load as minimum load ?
    I was searching for this question and you answered perfectly.
    06:30
    Keep posting thanks.

    • @PHARMAVEN
      @PHARMAVEN  Год назад +1

      Many Thanks For Your Appreciation, Please also share to your Friends and Groups and Juniors to Spread Knowledge

  • @PHARMAVEN
    @PHARMAVEN  Год назад

    What is Fix Load in Autoclave? ​⁠ #autoclave #sterilization #validation #ich #dhaval

  • @pravinsingh8170
    @pravinsingh8170 Год назад

    Validation me kitne cycle calate hai kitna uspe sir pa video bnaaye

  • @pravinsingh8170
    @pravinsingh8170 Год назад

    Ap validation sterilization autocalve paer video banaiye

  • @pushkarrawat5272
    @pushkarrawat5272 Год назад +1

    If we need sterilized other material (eg.forceps) which is part of maximum load but not identified as a worst case material, than we put both material (required item + worst material identify)during run of minimum load or only put required material(forceps) and start minimum run.

    • @PHARMAVEN
      @PHARMAVEN  Год назад +1

      In such case, you need to put all load items validated as minimum load and the item (forceps).
      You must put what was validated as minimum load for every such case

    • @pushkarrawat5272
      @pushkarrawat5272 Год назад +1

      @@PHARMAVEN thanku sir

    • @PHARMAVEN
      @PHARMAVEN  Год назад +1

      Welcome Pushkar

  • @sumitkumarsharma3914
    @sumitkumarsharma3914 Год назад

    Sir plz make a video on Hot VLT and Cold VLT
    I want to difference between in both in detail

  • @saurabhmehta9173
    @saurabhmehta9173 Год назад +1

    Thanks Dhaval bhai for such an informative video
    Can you suggest which pharmacopeia to refer for defining validation tempelate in a regulated environment?

    • @PHARMAVEN
      @PHARMAVEN  Год назад

      Any Pharmacopeia will not have templates for validation. Regulatory guidance and 21 CFR Rules provides rules and guidance to follow. Documentation templates we have to make of our own. There are various sites which provide templates, you can choose suitable one and can also modify to suite your requirements

  • @pravinsingh8170
    @pravinsingh8170 Год назад

    Ye hospital se relatevie video banaye hai ya pharam comapny mu use hone Wale autocalve validation 37 ye kya hai kis guidelines me hai

  • @VinodKumar-hv3hg
    @VinodKumar-hv3hg Год назад +1

    If you validate the max load. It means there is no panitration problem. How can panitration problen in comes in minimum load.

    • @PHARMAVEN
      @PHARMAVEN  Год назад

      Steam follows easy path. In Maximum Load, There is no escape for steam due to load and forced penetrate load. In minimum load, steam has lot of empty space to escape hence can be a problem for penetration

    • @VinodKumar-hv3hg
      @VinodKumar-hv3hg Год назад +1

      @@PHARMAVEN I think Mini load have more surface area for steam working in comparison of maximum load more side of material has been covered by each other. More surface area. more active side, more action.

  • @thyagarajanparthasarathy9442
    @thyagarajanparthasarathy9442 8 месяцев назад +1

    Try to explain in English sir.

  • @rushalinaik9813
    @rushalinaik9813 Год назад +1

    My question is Can we take only maximum load during annual validation as a worst case scenario.
    Because we have validate minimum load during PQ for thrice and continued the practice for annual validation till date. so on the basis of substantial data of minimum load we can take only maximum loads as a worst case scenario.however our autoclave is about 12years old so we have enough data for minimum load pattern which r found satisfactory.
    Kindly send your feedback.

    • @PHARMAVEN
      @PHARMAVEN  Год назад +1

      Based on risk assessment and data analysis, you can eliminate some of minimum loads
      I recommend that the load Pattern for product which are filed to agency should be done, other loads such as garments, sanitization load etc can be eliminated

    • @rushalinaik9813
      @rushalinaik9813 Год назад

      Thank u sir

  • @redride6517
    @redride6517 Год назад +1

    But sir when max load successfully completed then why MIN load require while already done MAX load

    • @PHARMAVEN
      @PHARMAVEN  Год назад

      In my video. Refer section at minute 6:30