    Difference between lag time and equilibrium time

  • @ravaljinang8389
    @ravaljinang8389 7 месяцев назад +1

    Diff. Btwn lag time and equlabrium time

  • @sumantakumarjena484
    @sumantakumarjena484 5 месяцев назад

    Sir,Sip ka Impact/Risk assessment ka video.

  • @rakeshbariya-v7z
    @rakeshbariya-v7z Месяц назад

    mfg CPP ka video bhejo

  • @domendrasahu4058
    @domendrasahu4058 2 месяца назад

    Sir psg ka pressure kitna rhna chahiye

  • @mayankdhiroliya
    @mayankdhiroliya 7 месяцев назад +1

    Sir, Gas filter or J tube ka kya use hota hai storage vessel me

    • @PHARMAVEN
      @PHARMAVEN  7 месяцев назад

      Gas filter for filtering gas when solution level comes down
      J tube is to transfer solution from mixing vessel to filtration vessel

  • @namratajain415
    @namratajain415 2 месяца назад +1

    During operation When temperature drop on 121 so in case sip cycle valid or not

    • @PHARMAVEN
      @PHARMAVEN  2 месяца назад

      It cannot be considered as valid but need more information to understand that at what time it drop, for how many seconds or minutes, what was total time of sterilization and at what location it went low and at how many locations it went low

  • @Rakesh-wj9vn
    @Rakesh-wj9vn 6 месяцев назад +1

    Sir in vessel line there is formation of condensed due to which temperature not reaching 121 so why this condenset is forming in lines what is the reason?

    • @PHARMAVEN
      @PHARMAVEN  6 месяцев назад

      I will make video on this
      Can you share vessel size , steam trap is there or not, vessel line diameter, length of line, how sensor is placed? Give as much of information available with you as you can

    • @Rakesh-wj9vn
      @Rakesh-wj9vn 5 месяцев назад

      500L vessel yes steam trap is there off inch diameter sensor is placed horizontal to the line
      Line length is not sure may be 3/4 feets

  • @mohitbisht2041
    @mohitbisht2041 4 месяца назад

    Sir what is the leak rate value in sip ... In our company the acceptance limit 0.20 bar that is higher then autoclave why ??

    • @PHARMAVEN
      @PHARMAVEN  4 месяца назад +1

      In SIP, usual practice is to set 1 bar pressure and 0.1 bar reduction is allowed after 30 minutes of hold. Unlike autoclave, in SIP, pressure is maintained after SIP throughout before filtration is started hence there is no ingress of non-sterile air in vessel.

    • @mohitbisht2041
      @mohitbisht2041 4 месяца назад

      Thank you sir