D R C 's TXV disassembly, inspect and reassembly

Поделиться
HTML-код
  • Опубликовано: 22 авг 2024
  • My video is on a thermal expansion valve (TXV), disassembly, inspection and reassembly. This valve is in a reach in frozen food case in a supermarket. The refrigeration equipment is a multiplex compressor rack controlled by a CPC E2 controller. Enjoy and please like, any comments or requests are welcome.

Комментарии • 54

  • @sunwinwk3650
    @sunwinwk3650 6 месяцев назад

    after 8 years there are still people to watch, the video is useful for me, you are the man, Thank you very much , I appreciated it.

  • @ryanmalin
    @ryanmalin 6 лет назад +3

    everytime that happens, just a suggestion, put a sight glass inside that case and write with paint marker "furthest case from rack" as it tends to be the futhest case from the rack. I also make sure if the case isnt feeding, close maybe half or 3/4 liquid ball valves (if not a loop system) then you can see if the temp drops and fixer quicker. Thanks for the video

    • @samho9318
      @samho9318 4 года назад

      Hello Ryan, I know this is yr. Old thread, but I must have to ask hopefully you can help me to better understanding of the ref. System

    • @samho9318
      @samho9318 4 года назад

      Sorry I hit the send button 🤣

    • @ryanmalin
      @ryanmalin 4 года назад

      @@samho9318 hey man, get into supermarket refrigeration. Contact Hill Phoenix and ask them for some guidance to schooling or training in your area

  • @Jpriatna
    @Jpriatna 5 лет назад +2

    Yhank for sharing inspection exspansi valve

  • @mikehardin7086
    @mikehardin7086 5 лет назад +4

    Thank you for the video. I am concerned that I over heated a TXV, I will use your technique to inspect it before I charge system.

  • @captainmigs1655
    @captainmigs1655 3 года назад +2

    Perfect video my guy! Subscribed and plan on watching your videos. Keep it up!

  • @JaykeSapalaran-iq3qs
    @JaykeSapalaran-iq3qs Год назад

    Great video tutorial 👍❤ thank you for sharing your knowledge and experience 🇵🇭🫡

  • @Ihartdabears85
    @Ihartdabears85 Месяц назад

    Hate when they use dye multiple times knowing the txv is there. Stratus for the sniffing win. H10 not too bad just a big ole gal

  • @AliBaba-cf4iu
    @AliBaba-cf4iu 5 лет назад +2

    Nice job man very thorough

  • @DragonflyAcres2022
    @DragonflyAcres2022 3 года назад +1

    Nice video thank for sharing

  • @pedrojardim1163
    @pedrojardim1163 4 года назад +3

    wow good staff

  • @MALIKA544
    @MALIKA544 4 года назад +2

    normalement le bulbe du detendeur doit etre isole thermiquement pou r donner la valeur reelle de la temperature de la tuyauterie d asoiration , sinon , une bonne video

  • @idiots830
    @idiots830 6 лет назад +2

    I think that freezer have refrigerant leaking problem.therefor got moisture through the leaking point. maybe TXV clogged by moisture freeze up and refrigerant got high friction through the TXV. maybe moisture was not enough to make 100% clogged the TXV. if TXV got 100% clogged, and then freezer food will be melting and freezing and melting.

  • @emergencyexit2510
    @emergencyexit2510 5 лет назад +2

    tnx

  • @bmillwood6666
    @bmillwood6666 3 года назад +3

    Power heads are cheap. Always replace power heads when working on a txv.

    • @steve0826
      @steve0826 3 года назад

      Just replace with any power head, or there are some specifications to pay attention to?

  • @eric4467
    @eric4467 7 лет назад +2

    Thanks!

  • @Eljfroxs26
    @Eljfroxs26 3 года назад

    ang galing nyo po

  • @Bluecollarrebel
    @Bluecollarrebel 3 года назад

    Nice

  • @Gary-ts6dh
    @Gary-ts6dh 6 месяцев назад

    3:45 - What did you use to clean the valve body? more contact cleaner? I guess that's ok for the refrigerant circuit?

    • @DRCProductions
      @DRCProductions  6 месяцев назад

      Usually I don’t use cleaner but have no problem using contact cleaner because it dries up clean.

  • @airmech5083
    @airmech5083 2 года назад

    Shut the case downstream, if this case temp start dropping ya low on gas.

  • @Salmanofficial1788
    @Salmanofficial1788 5 лет назад +1

    Sir, we have turned on contractors by doing this, after that the contractor turns off, after that we put the charging line on the section, then its pressure goes to vacuum and the discharge pressure is 200 stand nor forward or backward.

  • @jellytae6851
    @jellytae6851 2 года назад

    When you clean Txv valve does need to vacuum suction line or either shout down unit and clean txv valve and put back together and turn unit back on ?

    • @DRCProductions
      @DRCProductions  2 года назад

      Low temp you usually need to pull a vacuum. Any time you open up a system you should pull vacuum, this particular case had valves in the case so it was a quick evacuation. I cannot say that I have never done a quick purge and merge DRC method of reassembly of the valve. Sometimes valves are not holding somewhere in the system and there is always a slight positive pressure blowing by the valve during disassembly which I consider no air introduction into the system. Hence purge and merge. Always take into consideration of existing conditions.

  • @HVACRSurvival
    @HVACRSurvival 8 лет назад +1

    What was determined to be the problem? Powerhead or improper superheat adjustment?

    • @donalddperez
      @donalddperez 7 лет назад +2

      ucantstopthis1
      This system was low on charge. It happens.

    • @marks9935
      @marks9935 6 лет назад +3

      Really? And you couldnt figure that out without dismantling the TXV?

    • @DRCProductions
      @DRCProductions  5 лет назад +3

      Knew it was low on charge, wanted to make a video.

    • @SombraLocs
      @SombraLocs 5 лет назад +1

      @@DRCProductions Would it frost up on the capillary tube side if it was not feeding properly?

    • @u2ooberboober
      @u2ooberboober 4 года назад +1

      At least now I know to pump down the system before removing the power head!!

  • @automatictrader7913
    @automatictrader7913 4 года назад +1

    thats right go hulk on it so the next guy will have to cut open his fingers to loosen it

  • @Salmanofficial1788
    @Salmanofficial1788 5 лет назад +1

    50 tan packeg ac carrier

  • @hugovalenzuela6669
    @hugovalenzuela6669 2 года назад

    If my a remplace the txv

  • @l.crossjr
    @l.crossjr Год назад

    Is there such a thing as a quick TXV test without opening the system?

    • @DRCProductions
      @DRCProductions  Год назад

      Use your your senses first
      Vision, is there frost on the pipe leaving the TXV?
      Touch, feel the valve for temperature differential.
      Hearing, listen - is the valve whistling, low charge?
      Smell, can you smell refrigerant?
      Senses will get the obvious and use meters and gauges for verifying your god given senses. Cheers!

  • @guangxfang1477
    @guangxfang1477 3 года назад

    Is Sporlan KT-43-SZ Expansion Valve Element 60" use for walk-in freezer?

    • @dbp1926
      @dbp1926 3 года назад

      yes.
      KT=Kit
      43 = the size of element
      S = Refrigerant Type
      Z = Low Temp

  • @lancerudy9934
    @lancerudy9934 4 года назад +1

    The screen is clogged

  • @ninosanchez8798
    @ninosanchez8798 2 года назад

    Didnit work or not?

  • @UltraHydrophobiccoat
    @UltraHydrophobiccoat 4 года назад +1

    No nylog blue needed for the threads?

    • @DRCProductions
      @DRCProductions  4 года назад +1

      Superhydrophobic Coating not that day. 👍

    • @DRCProductions
      @DRCProductions  4 года назад +1

      Superhydrophobic Coating I like Loctite 567. That sealant is the kind

    • @bmillwood6666
      @bmillwood6666 3 года назад

      Nylog was not around five years ago

  • @javiertrejo2694
    @javiertrejo2694 4 года назад

    mmmm 2 dos

  • @Salmanofficial1788
    @Salmanofficial1788 5 лет назад

    Please answer