Temporary electrical service setup

Поделиться
HTML-код
  • Опубликовано: 25 окт 2024

Комментарии • 77

  • @patyagecic3075
    @patyagecic3075 4 года назад +1

    Hello Scott, been watching you since you started on RUclips. You are a class guy, and should be very proud of your accomplishments you and Kelly have completed on your new property! Your Solar system is Top notch "best of the best" ! Peace

  • @notajp
    @notajp 4 года назад +4

    VERY familiar with those RV panels. I spent a lot of time inside those when I worked maintenance for the county parks department. Replaced a lot of sockets, GFCIs, and breakers in those things over the years.

  • @randyloosemore4978
    @randyloosemore4978 4 года назад

    hello scott wow looking good you will soon have tempprary electrical service very very soon totally awesome for you and kelly both thanks for update and this video so until next video i'm about to watch i say so long for now take care from Randy.from ontario.canada .p.s please stay safe out there .

  • @nashguy207
    @nashguy207 4 года назад +3

    Nice work I know it will be nice to have some power on the property.

  • @agentofficerthomasa.porter107
    @agentofficerthomasa.porter107 4 года назад +2

    You might want to think of buildking a pitch roof 3 feet either side to give shelter to the power box's keep rain & snow from get'n on it. Look'n Great! Be easy to do ply-wood & 2/4's! always, Tommy :-)

  • @donmoore7785
    @donmoore7785 4 года назад

    Very nice. Great progress. 100A for a temporary service should be fine. I put 100A on a neighbor's shed, for camper hookup, and 150A to my small cabin a few years ago. No need for 200A and easier to work with. When you build a house, you can use 200A if you want.

  • @glennmanchester1568
    @glennmanchester1568 4 года назад

    Here in FLA we have to use two ground rods six feet apart or better they can tie together and normally the feed comes in overhead so a normal pole is the standard the wires come out of the top of the meter can up the mast to at least 12 ft and rain cap out of the bottom of the meter can an exterior panel of whatever size all the new ones would be 200 amp if your doing it anyway may as well just have plenty for whatever may be on that lot in the future ..

  • @robertbrady9597
    @robertbrady9597 4 года назад +1

    hi scott an kelly nice job scott stay safe out by all you guys

  • @BackyardMaine
    @BackyardMaine 4 года назад

    FYI, you only bond neutral to ground in one location.

  • @danielseelye6005
    @danielseelye6005 4 года назад +1

    Have your thought about hooking up Lenny to the grid and feeding power back thus getting credit from the electric company?

  • @VikingShipExplorer
    @VikingShipExplorer 4 года назад +5

    It'll be great when you get the power in. I only had to trench 70 feet by hand and the electrical company did the 1/8 mile leading up to the green box in the yard. Hardest job I've ever had to do. But it was sure nice to not have to feed the gas generator any more. That first waffle in my toaster cost me just under $9 Grand.... but it sure was good....lol.

    • @donmoore7785
      @donmoore7785 4 года назад +1

      I did 250' by hand, but it was only 18" deep, in conduit. My job ended up free with the POCO, even though it extended the street line 1800 feet. I got two other new customers, and then a guy came on just a month ago which resulted in me and my neighbor getting back $3700 each - which is what we had to give the POCO. The POCO will probably never make any money on it - this is in the middle of nowhere and seasonal use.

    • @VikingShipExplorer
      @VikingShipExplorer 4 года назад

      @@donmoore7785 we have to go down 24 inches. Deeper if you want to run electrical over gas. In which case I believe it's 3 feet for gas and 2 feet for power. If anyone else wants both down the line and they want to hook on to my lines, then I will get money back on both. Unfortunately neighbors on both sides have both already so, no money coming my way....lol.

  • @jamesswetland5019
    @jamesswetland5019 4 года назад +1

    We have 5 acres in NC we had that temporary power for 20 years. We have a trailer on our property and pay $55.00 a month.

  • @rosymaam68
    @rosymaam68 4 года назад

    The power was for Tyler but the internet.......THAT'S FOR DADY!!! ;)

  • @epenzenstadler3895
    @epenzenstadler3895 4 года назад +1

    I am surprised they required GFCI for the RV plugs. Will the internet company connect you up with temporary power? My company wanted permanent power to the ONT box. It would be sweet to have internet with your temporary power. I hope you get lucky!

    • @etripp111
      @etripp111 3 года назад

      Pretty sure the NEC does NOT require the RV outlets, 50 amp or 30 amp, to be GFCI protected.

  • @TimsWorkshopTJY
    @TimsWorkshopTJY 4 года назад

    Good job on setup and inspection👍

  • @akdisney
    @akdisney 4 года назад

    Like you said The picture did not show Whole story I'm happy you pass electrical inspection.

  • @neil6212
    @neil6212 4 года назад

    Grounding wire: #4 copper. Typically bare. Use the green box bonding screw that came with the box.

  • @garyrobinson8991
    @garyrobinson8991 4 года назад

    Very. Nice. Work !

  • @anonymousnoah6173
    @anonymousnoah6173 4 года назад +1

    Don't you have to have a main disconnect breaker?

  • @glossamano1899
    @glossamano1899 4 года назад

    Cool, nice work, Scott. Had to google GFCI which is RCD (Residual Current Device) in Australia. You seem to be a man of many talents, a diesel mechanic, pilot and an electrician as well.

  • @vdivanov
    @vdivanov 4 года назад

    Looks great! Can't believe there are RVs that still use TT-30.

    • @daviddavis7855
      @daviddavis7855 4 года назад +1

      Probably a majority use TT-30. 50A is used on class A's mostly for two A/C's. Trailers and class C's almost all use 30-TT

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад +1

      Many of the rv’s i work on were converted in the 70-80’s. I don’t even think 50a plugs were used back then for rv’s

    • @vdivanov
      @vdivanov 4 года назад

      @@daviddavis7855 Interesting... Even 14-50 seems a bit hazardous, would have though that locking plugs/receptacles as used at the marinas or for generators would be preferred.

    • @vdivanov
      @vdivanov 4 года назад

      @@BusGreaseMonkey Probably not, NEMA 14-50 came in the early '90s, right? Many RV parks still have TT-30 and regular NEMA 5-15 120V only.

    • @daviddavis7855
      @daviddavis7855 4 года назад +1

      I use twist lock at the RV side. Expense is another thing, RV parks may have hundreds of sites, many 30A only. Cost of marina style would be much more.
      At least there is a safety ground on each.

  • @christophercudia8354
    @christophercudia8354 4 года назад

    great job

  • @cw3339
    @cw3339 4 года назад

    Power to the People!

  • @peterwall9896
    @peterwall9896 4 года назад

    I'm in the UK and I love it 😎

  • @capefearalive
    @capefearalive Год назад

    Dimensions on the actual pole/poles. How wide and how tall?

  • @natevanlandingham1945
    @natevanlandingham1945 4 года назад

    Haha, I noticed that junction cap hanging loose in the community post.

  • @charlesc.6767
    @charlesc.6767 4 года назад

    NO MAIN BREAKER OR FUSSIBLE DISCONECT? In california its required . But codes are different across the u s, Even though we all use the n e c , the local utility and local building department also have there own requirements , so only a local would know whats required there . Good luck

  • @blaircr4496
    @blaircr4496 4 года назад +4

    "Power by the end of the week" and internet??

  • @derekobidowski3301
    @derekobidowski3301 4 года назад

    Will you have 3 phase power to your planned shop? as some tools do require 3 phase power if your service offers it as another way is a rotary phase converter using a 10+ hp 3 phase motor as that will create the 3rd leg of the power. i see you temporarly got 100 amps of 120/240 volt single phase service. as im sure which vintage bus would require large tools for to weld, fabricate parts for your client's busses or trucks. be cool to do that.

  • @alzdeane
    @alzdeane 4 года назад +1

    Genuine question - as your solar rig is so good, and produces surplus power, why do you need grid electricity also? I guess running shop equipment down the line?

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад +2

      Visitors. Plus when the bus leaves still having power on the property

  • @akdisney
    @akdisney 4 года назад

    For the people out there and think add a RV power from your house. This is (Temporary electrical service) so all receptacle need to be GFCI protection. if doing to your house is a permit electrical service and 50 amp and 30 amp Do not need
    GFCI protection. You are do a service feed to RV breaker panels

    • @etripp111
      @etripp111 3 года назад

      Not true.

    • @akdisney
      @akdisney 3 года назад

      @@etripp111 Ok show in NEC article say that 50 amp and 30 amp need to be GFCI protection. recreational Vehicle parks 512.41 C Ground- fault Circuit-Interrupter Protection Where Provided, each 125-volt, single-phase, 15-or 20- ampere receptacle outlet Shall have Ground-fault circuit-interrupter protection for personnel
      why no GFCI You get volt spike and on 30 amp and 50 amp you get Unbalance load. NEC say you can't have two GFCI protection on a same branch circuit. you have GFCI in the RV

    • @akdisney
      @akdisney 3 года назад

      @@etripp111 You can look up on internet show
      the 30- and 50-amp circuits feeding the RV are NOT required to have GFCI protection. Preventing the inclusion of GFCI protection of 30- and 50-amp RV site circuits is a big deal and operators need help to prevent a future push to include them by GFCI protecting circuits that should be protected.

  • @pcspecialistpdx
    @pcspecialistpdx 4 года назад

    I never understood why the height requirement is different than in RV parks where it is much lower.

  • @kevinhamling1963
    @kevinhamling1963 4 года назад +1

    One more job ticked off the list.
    ✌ Peace guys.

  • @barrypierce9100
    @barrypierce9100 4 года назад +1

    Where's the ground rod.. ??????

  • @tc-xe1fm
    @tc-xe1fm 4 года назад

    is the JHA inspector allowing the exposed & above ground PVC because it temporary? or maybe your going to protect from physical and UV damage later? again, just curious!!!

    • @glennmanchester1568
      @glennmanchester1568 4 года назад

      The grey pipe in lieu of white PVC is uv protected and depending on where it's located if there's any way a vehicle could hit it parking lot etc it requires posts if it's not near any vehicle traffic it's not needed who's going to drive into it ??

  • @boards65dilligaf20
    @boards65dilligaf20 4 года назад

    Congratulations

  • @daviddavis7855
    @daviddavis7855 4 года назад +1

    Did they require two ground rods? I had to put in two in my NC property.

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад +5

      Just one. I did 1.5 thanks to a large rock

    • @daviddavis7855
      @daviddavis7855 4 года назад

      Did you bond them together? Just curious.

    • @proehm
      @proehm 4 года назад

      Two rods increases the risk of lightning damage. (Creates a loop).

  • @bruceadler-9410
    @bruceadler-9410 4 года назад +2

    I suggest you add a disconnect between the meter and breaker box. At some point you're going to want to add another branch circuit. But, without a disconnect you'll either have to risk working on the box while it's hot (not a problem if you're a professional electrician, but you're not a pro), or you'll have to call the power company to pull the meter and then re-install the meter.

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад +1

      TEMPORARY Service. Its fine. 100a less than 6 circuits does not require shut off. It’s all good. Also no plan to add any circuits 200a will be going to the shop

    • @bruceadler-9410
      @bruceadler-9410 4 года назад +2

      @@BusGreaseMonkey I understand it's not required. I'm just saying sometimes temporary lasts a lot longer than anyone expects - life intervenes and causes plans to change.

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад +3

      I purposely made it 100a so i wouldn’t be tempted to use it permanently :)

    • @abpsd73
      @abpsd73 4 года назад

      @@BusGreaseMonkey I was wondering about the need for a main breaker/disconnect as well. Not being a troll, I'm an electrician in Canada for 19 years. Of course codes and regulations vary by state/country. Your workmanship looks pretty good for a do-it-yourselfer. Congrats on passing your inspection.

    • @glennmanchester1568
      @glennmanchester1568 4 года назад

      Nahhh just cut the tab off and pull the meter do your thing and put it back in service at least here it's no problem unless when they do come to read they see something that's just out of the question the smart meters report back a service interruption and if the power company does send someone out it's days later and the electrician needed to do some work is good

  • @michellepowell1956
    @michellepowell1956 4 года назад

    Who Made the RV panel?

  • @cheeseburger9232
    @cheeseburger9232 4 года назад

    They didn't ask for a copper water line ran there for the ground wire.

  • @promisel1964
    @promisel1964 4 года назад

    yay progress thats good :)

  • @tomblackwell9496
    @tomblackwell9496 4 года назад

    Most RV electrical systems will have enough leakage to trip a GFCI....

  • @rayhorner2965
    @rayhorner2965 4 года назад

    If install secondary cables, must be 18" below ground surface. and if install primary high voltage cable, it must be at least 36" below ground level.

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад

      Your Point??

    • @cwsill
      @cwsill 4 года назад

      @@BusGreaseMonkey MeTube self-righteousness, no doubt! 😆

  • @PaulieB1965
    @PaulieB1965 4 года назад +1

    Don’t see an expansion coupling....

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад +1

      :18 it’s in the box in the background

    • @PaulieB1965
      @PaulieB1965 4 года назад

      Bus Grease Monkey , good man. 👍🏻

  • @peterrogers9228
    @peterrogers9228 4 года назад

    When the tresspassers come in while you are away they will have access to power!!

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад +1

      So our security cameras and motion security lights will have power

  • @deans2790
    @deans2790 4 года назад

    A magnet on a string would retrieve that screw

    • @BusGreaseMonkey
      @BusGreaseMonkey  4 года назад

      Couldn’t see it. Out of line of sight. We tried a magnet and no luck. Then i tested the other screw and it was not magnetic

  •  4 года назад +1

    i make my own power (thanks not to god) solar and wind. no state interference. I hate em! :-)