Dixell control

Поделиться
HTML-код
  • Опубликовано: 3 мар 2019
  • Replace dixell control
  • ХоббиХобби

Комментарии • 68

  • @jeremyvoshage2410
    @jeremyvoshage2410 5 лет назад +3

    So glad I learned from an old school mechanic like you 👍🤟

  • @Reefertech
    @Reefertech 5 лет назад +1

    You make me want to get back into refrigeration! Fun stuff 🙌🏻

  • @BenTh17
    @BenTh17 5 лет назад +6

    “It’s gonna bang on and take the load” 😂
    Also I love your cat. Good video

  • @ronkurey8840
    @ronkurey8840 5 лет назад

    Another fine job..Dave...do it right the first time...that’s what I like!

  • @throttlebottle5906
    @throttlebottle5906 5 лет назад

    either sticking contact or the temp sensors are getting spotty and telling it to keep running warm box? unless you/they seen the control reading 25F also

  • @persimonsen8792
    @persimonsen8792 5 лет назад +1

    Why not using Danfoss ? Like a EKC202D, perfekt for all rooms, freezer or cold rooms. Great control of defrost and fans. Even with battery module, you can control for special defrost time. And nightmode.

  • @marvingarcia8982
    @marvingarcia8982 5 лет назад +1

    My man using True refrigeration compressor relay to help the dixell. I like the set up, am not sure if I would do it. That relay contacts sticks all the time. But the idea is undertood.

    • @OcRefrig
      @OcRefrig 5 лет назад +2

      i use contactors all day long. especially on freezers. that way i can inspect the contacts and replace.

    • @glasser2819
      @glasser2819 5 лет назад

      @@OcRefrig or you can add a "soft starter" and never replace the contactor or the motor... 7x in-rush be gone 👍🏻

  • @binhashimhvacrservices284
    @binhashimhvacrservices284 4 года назад

    The relay for load is the best thing to do.

  • @damianorsini4260
    @damianorsini4260 5 лет назад +4

    Hobart is like, "oh no he didn't, that's our sticker."
    #STICKERWARS

    • @OcRefrig
      @OcRefrig 5 лет назад +2

      Lol ! 🤣🤣🤣🤣🤣 Oh Yes he did ! 🤣🤣🤣🤣🤣

  • @st3v3281
    @st3v3281 5 лет назад

    What model relay is that Dave ? i would like to start installing also to take load off comp most units I service are always pulling high amps due to dirty cond coils or lack of air flow.. Great video

  • @joinusmorelikely5428
    @joinusmorelikely5428 Год назад

    That’s so crazy I was just thinking about. How effing ridiculous the dixell robustibility is or lack of. I can’t tell you how many dixell stats had to be replaced because of water….. how rediculous is that???? A refrigeration stat that susceptible to damage because of water…. Unreal dixell needs to get there stuff together….

  • @michaelmeyer6314
    @michaelmeyer6314 5 лет назад +1

    Again, lets replace an electronic with a pressure switch, the only reason the electronic was dead is that the unit on the rooftop was designed for indoor use only.

  • @glasser2819
    @glasser2819 5 лет назад

    your external relay solution is the best to fix junko controls.
    Those external relays specs are perfect for handling in-rush surge currents.

    • @NorCal-refrigeration
      @NorCal-refrigeration  5 лет назад

      They use them on true units.

    • @glasser2819
      @glasser2819 5 лет назад

      @@NorCal-refrigeration have you experimented "soft starting" motors: compressors, fans, pumps like on your private equipment. It saves the contactors and the bearings from destructive start surge currents and shaft translation (ATS01N125FT: "made in Germany" engineering for cheap. Both 1 and/or 3 phase motors) 👍🏻

  • @mahesh1757sardesai
    @mahesh1757sardesai 4 года назад

    What is EA ( letters blinking )error in dixell XR06CX controller, PLEASE reply at the earliest

  • @mahesh1757sardesai
    @mahesh1757sardesai 4 года назад

    what is EA error in dixell XR06CX controller, PLEASE reply at the earliest

  • @OcRefrig
    @OcRefrig 4 года назад +1

    That was a 2013 dixell. Lasted 6 years without a Relay taking the Load. i just replaced a dixell the other day. 2008 controller But , it Was using a Contactor to take the Load. 6 years Life No Relay or use a Relay and get 11 years Life out of controller. Goes to show you , You can double the Life of the Controller almost using a Relay. Good vid.

  • @leylyatl1049
    @leylyatl1049 Год назад

    Could you help me please how to set up US LS Hy and other if controller dixell is installed on the storage boiler and I want to have permanent hot water around 50-55 °C ??

  • @deanstanbank6200
    @deanstanbank6200 5 лет назад +2

    Do you ever use the Eliwell I.D. Chill n Freeze range over there. I use them quite a lot here in Blighty. I’ve found them to be a good, reliable controller.

    • @heavydiesel
      @heavydiesel 5 лет назад +1

      They are good controllers, I keep a ID Cool and ID Chill n Freezer on the van.

    • @deanstanbank6200
      @deanstanbank6200 5 лет назад +1

      heavydiesel Just subbed to your channel mate. After 12 years with the same company, I am finally giving it a go on my own. Looking forward to the new challenge.

    • @NorCal-refrigeration
      @NorCal-refrigeration  5 лет назад +2

      Dean Stanbank I have not but I’ll look into those. Thanks for the heads up. 👍

  • @michaelmeyer6314
    @michaelmeyer6314 5 лет назад

    If you went to a wholesaler you could buy a Dixell Universal replacement and use it right out of the box. Do not replace with a Penn or Ranco.

  • @stheodro
    @stheodro 5 лет назад +1

    can someone elaborate "Design pressures" on reach-in cooler data plate
    what it means?
    example on Traulsen G22013TS [R-404A]
    Design Pressure HIGH Side 350 PSIG LOW Side 250 PSIG
    is this talking about Max pressure the system can withstand?
    Thanks

    • @NorCal-refrigeration
      @NorCal-refrigeration  5 лет назад

      Schematics yep. Designed for max.

    • @stheodro
      @stheodro 5 лет назад

      @@NorCal-refrigeration Thank you Nor-Cal your channel has amazing content
      I love the tip you gave ( Dixell Control + Relay)
      would adding a fuse protect the controller any better? or would be a nuisance call?

  • @harrydickson4575
    @harrydickson4575 5 лет назад

    👍👍👍👍

  • @scrambler350
    @scrambler350 5 лет назад +2

    @ 9:38

    • @ceeceethecat
      @ceeceethecat 5 лет назад

      I didn't see any competition😹

  • @chrisbivens5410
    @chrisbivens5410 5 лет назад

    Sick dog house. Crazy Those little shit controls handle the load. It is what it is.

  • @ceeceethecat
    @ceeceethecat 5 лет назад +1

    Such a beautiful cat😻

  • @michaelmeyer6314
    @michaelmeyer6314 5 лет назад

    The relay is a cheap Omron 30 amp that will fail before the control will.

  • @seanintia77
    @seanintia77 5 лет назад

    ☝️

  • @frostcontrolhayder3463
    @frostcontrolhayder3463 5 лет назад

    why the place of control is installed in the outdoor unit?usualy in the indoor.

    • @NorCal-refrigeration
      @NorCal-refrigeration  5 лет назад +1

      It’s not a temp a controller, it’s the outdoor unit controller low pressure high pressure fan cycle time delay and more.

    • @frostcontrolhayder3463
      @frostcontrolhayder3463 5 лет назад

      @@NorCal-refrigeration we donot have frigs like this,its 🆒😂

  • @russell4309
    @russell4309 5 лет назад +2

    1:15 get that Hobart outahere!!

  • @Portergetmybag
    @Portergetmybag Год назад

    Why RUclips unsubscribed me from a non controversial channel like yours ill never understand

  • @cesservicedepartment3609
    @cesservicedepartment3609 5 лет назад

    Good video, where are you getting your dixell controllers, united refrigeration charges a little to much.

  • @MaikelJordao
    @MaikelJordao 6 месяцев назад

    Okey okay okey okay 🤣👍🤣👍

  • @throttlebottle5906
    @throttlebottle5906 5 лет назад

    hiss hiss, scratch, meow... I'm not too good at cat language ;)

  • @TheTeto209
    @TheTeto209 5 лет назад +1

    One day can you do a video on how to read wiring ?

    • @NorCal-refrigeration
      @NorCal-refrigeration  5 лет назад +1

      Gray furnace man has a series up right now. Go check out his channel he is the very best!!!

    • @germane3955
      @germane3955 4 года назад

      Read the schismatic there is you Answer

  • @gonzgarr1592
    @gonzgarr1592 5 лет назад

    Cal man did anybody you know Knows what ever happen to jim pettinato have not see any vidios from him for about 2 yrs
    just wondering if he is O.K

    • @scrambler350
      @scrambler350 5 лет назад

      One of the other guy's in the RUclips HVAC community claimed he stopped doing vids because he was getting too much attention from people locally and at his supply house or something like that - think he just went low-key.

    • @gonzgarr1592
      @gonzgarr1592 5 лет назад

      @@scrambler350 thanks for the info

  • @Eddy63
    @Eddy63 5 лет назад +2

    1st comment Super Dave ... Do I win a Vangina full of liquor ... Lol ... Good vid ...

  • @throttlebottle5906
    @throttlebottle5906 5 лет назад

    dixell or dix-smell :))))

  • @oumarkasse3251
    @oumarkasse3251 2 года назад

    Alarme da

  • @rocker8692
    @rocker8692 3 года назад

    People need to at least clean their coils,takes 5 minutes

  • @OcRefrig
    @OcRefrig 5 лет назад

    Good vid. where are u getting your dixells from ? ill bet kinda pricey ? u can text if u want.

  • @st3v3281
    @st3v3281 5 лет назад +1

    What model relay is that Dave ? i would like to start installing also to take load off comp most units I service are always pulling high amps due to dirty cond coils or lack of air flow.. Great video

    • @NorCal-refrigeration
      @NorCal-refrigeration  5 лет назад

      True 800182 Relay www.amazon.com/dp/B00EMJYRJ0/ref=cm_sw_r_cp_api_i_5M1FCbRPPJ4PF