Please explain casing pipe installation for some crossing locations in order to protect the non-metallic pipe. Please explain the new topic for RTP pipe installation, onshore wellheads, production manifolds, flowlines, remote manifolds, trunklines, CI and SI lines (corrosion inhibitor and scale inhibitor lines), and blowdown skids, in a simple point-by-point manner."
What is the leakage class of check valve....generally we all knew leakage class applicable for isolation valve,but check valve is not a isolation valve. So what is the leakage class to be maintained in check valve?
Thanks sir for video Which type of check valve in case of flow from upward to downward Lines connected to vessel nozzle And client have requirement to connect check valve on nozzle to avoid back flow In reactor Kindly reply
Your videos are gold material, very informational and intuitive. Thanks for uploading.
Very informative as a trainee working in valve i understand many things from these video. Excellent work sir 🎉🎉 thank you for uploading🎉❤
Very nice video
Very good video 👍
Very very beautifully explained video. Thanks a lot for the uploading such informative video.
Very nice sir 👍
Very nice 👍
Very nice sir
Very nice informative video sir
Nice 👍👍
Very nice
Very very nice
Very good
Thank you sir
❤
Please explain casing pipe installation for some crossing locations in order to protect the non-metallic pipe. Please explain the new topic for RTP pipe installation, onshore wellheads, production manifolds, flowlines, remote manifolds, trunklines, CI and SI lines (corrosion inhibitor and scale inhibitor lines), and blowdown skids, in a simple point-by-point manner."
What is the leakage class of check valve....generally we all knew leakage class applicable for isolation valve,but check valve is not a isolation valve. So what is the leakage class to be maintained in check valve?
Thanks sir for video
Which type of check valve in case of flow from upward to downward
Lines connected to vessel nozzle
And client have requirement to connect check valve on nozzle to avoid back flow
In reactor
Kindly reply
You can go for non-slam wafer type check valve.
@@gourisankarsamanta7670
Thankyou sir
Sir for pump discharge line sizes upto 4" we should go for vertical type arrangement,but for 6" and above we prefer horizontal type arrangement.
I have seen vertical piping upto 8" size.
I think we can go for vertical piping upto 10" or 12" size also.