Thanks, very good video, explained well. My only suggestion is as you said we use ISO so all your later video is Grade system , if you can change to ISO 5 , ISO 6 , ISO 7 and ISO 8 will be better.
Hello, could you explain to me how the air changes per hour for a class 8 cleanroom are recommended between 5 and 48 ACH?. Basically ISO 14644 does not explain a specific value for room classification, however the FDA mentions that for class 8 clean rooms is recomended at least 20 ACH. My question is, despite what is mentioned by the FDA, are the ranges from 5 to 48 ACH valid?. Pd. Thank you so much for sharing this information to clarify information about cleanrooms 🙏🏻
It is a general understanding as the clean room status goes towards 8 to 5 the ACH are increased so In my point of view ACH should be such that it should easily swipe any dust generation in class 8.
Thanks for clarification But clarity required on calculating air changes per hour.. microbial count and other things which are pending to be explained in other vedioes
Sir my question is there i hope you will answer that my question is if we do microbial count or viable count in cleanroom then why there is need to do non viable particular count in cleanrooms
You are really great sir. It helped me a lot . Thank you so much sir
wel come
Thanks, very good video, explained well. My only suggestion is as you said we use ISO so all your later video is Grade system , if you can change to ISO 5 , ISO 6 , ISO 7 and ISO 8 will be better.
Very nice information
Thanks
is it a GMP requirement for non-sterile products i.e. tablets, capsules, oral liquids to be manufactured in a clean room such as grade D?
All regulatory bodies
very well explained. JazakAllah khair
thanks
Super explanation. Please describe method of monitoring viable and non viable along with Qualifications of HVAC
thanks.i will
Very informative🖤
thanks
Super sir ji comparing super iso and grades
Thanks sir ,video cleared the concept 👍🏻
well come.reshare it
Thanks for this info
well come
Hello, could you explain to me how the air changes per hour for a class 8 cleanroom are recommended between 5 and 48 ACH?. Basically ISO 14644 does not explain a specific value for room classification, however the FDA mentions that for class 8 clean rooms is recomended at least 20 ACH. My question is, despite what is mentioned by the FDA, are the ranges from 5 to 48 ACH valid?. Pd. Thank you so much for sharing this information to clarify information about cleanrooms 🙏🏻
It is a general understanding as the clean room status goes towards 8 to 5 the ACH are increased so In my point of view ACH should be such that it should easily swipe any dust generation in class 8.
👏👏👏👏👏
Very good video.
thanks
مشاء الله 🤝
Thanks for clarification
But clarity required on calculating air changes per hour.. microbial count and other things which are pending to be explained in other vedioes
Yes I will record
Thanks for ur calrification. Kindly write the notes in board for our clear vision. It my one suggestion for u update.
Updated video will be uploaded soon.The article link is also provided in description
Sir can you tell me what is the sampling time for non viable particle count for class D?
its depend on
room vol mean saple locations are cal acc to room vol.
Super and easy learn
thanks
Dispensing area kon si class me hota h sir?
Sir injectables are categorized into which ISO class?
Please reply..
filling & sealing grade A
MashaAllah❤❤❤
Can you tell from room to room? how much differential pressure should be kept Grade according
kindly make video on validation
will try to record soon
Nice sir ji
Thanks
Good topic
Sir please clear update partical count list iso accounting
Sir my question is there i hope you will answer that my question is if we do microbial count or viable count in cleanroom then why there is need to do non viable particular count in cleanrooms
To prevent cross contamination
Sir ji Batch manufacturing process drugs ki video bhi banao Kitna excipient , api kese mixing krke batch ready krte hai
will try
Can you provide pdf document
Reply sir
MashaALLAH sir
thanks
@@Pharmainform sir Mai nay sterile class A b c area search k to app k vdo ayi smny...Mai nay app k utube chinl nhi dika ta phly❤️
video is easy to understand or not?
Could you please add English subtitles in all your videos, because we have problem with those in non English!
its in eng language
Good
Thanks
Hindi mai bol lete sir
@pharmainform could u plz give me opportunity, i wat to become part of your team to expand this channel
How?
@@Pharmainform it's up to you sir which part u will give me for work
Contact using about Section info
thank you