  • @ajsommer5
    @ajsommer5 3 года назад +6

    I've had this unit which I self installed 12 years ago - it's an excellent quality product. As you have done, the flush out valves are a must for annual maintenance. Whole house filtration is recommended as I have a well. The customer service is great as well - I have had the elements replaced 8 years back, then the unit failed two years ago. With the warranty, they overnighted replacements after pics were provided.

    • @JunkworksGarage
      @JunkworksGarage  3 года назад +2

      👍 thanks we have bean happy so far too

    • @judichristopher4604
      @judichristopher4604 2 года назад +1

      That sounds like you would surely recommend this unit... Yes?
      Thanks for the information.

  • @murrat
    @murrat Год назад +2

    Thanks for making this video.

  • @alonattias9312
    @alonattias9312 3 года назад +1

    I have already electric water heather (no tankless) that controls 2 bathrooms and a kitchen . It make the process easier with the plumbing ?
    Because I just going to use the pipes that connected already to the current water heater.
    Basically what I want to understand it’s if I want to control multiple bathrooms and kitchen, I need to connect all the pipes from each area and the it will control all of them ?

    • @JunkworksGarage
      @JunkworksGarage  3 года назад

      yes it would work the same as the tanked water heater but this unit needs a lot more power so athow the plumbing would work the same you would have to run more electrical to the water heater

  • @kommoncents5853
    @kommoncents5853 3 года назад

    Did the relief valve come with the heater or the valve kit ? Have you seen any reduction on your electric bill since you installed it ?

    • @JunkworksGarage
      @JunkworksGarage  3 года назад

      it came with the valve kit . it's hard to tell cost because i completely remodeled and changed the heaters too and are heating company keeps increasing the cost

  • @thecataclysmitician4661
    @thecataclysmitician4661 Год назад +2

    A good video on what NOT to do!

    • @JunkworksGarage
      @JunkworksGarage  Год назад +7

      it passed code in my state and is still working great.

  • @a747ba
    @a747ba 2 года назад

    can you provide a link to the valve kits you bought on amazon??? thanks ! great video!

    • @JunkworksGarage
      @JunkworksGarage  2 года назад

      athow i am figuring things out i am not good with computers and haven't figured out how sorry. i will be working on that when i get a chance. look for water heater pressure relief valves and serval should pop up 👍

  • @seanndiane
    @seanndiane Год назад

    I’m attempting to move an ecosmart 27 that came installed in a tiny home. The manual says the heater must be installed 24” from combustibles. How were you able to put it in a cabinet?

    • @JunkworksGarage
      @JunkworksGarage  Год назад

      I don't remember the exact specs on mine but i measured and the cabinet was big enough for safe distances from all sides and front

  • @123mjolie
    @123mjolie 6 месяцев назад

    Thank You !!!

  • @777-Phil
    @777-Phil 2 года назад

    Thumbs up: Utmost blessings!

  • @olwe1000
    @olwe1000 3 года назад

    any Updates on the water heater?. It has been several months. Thanks in advance.

    • @JunkworksGarage
      @JunkworksGarage  3 года назад

      so far so good i will do an update after i finish my kids place but it will be a little ways down the road 😁

  • @MrJar1rad
    @MrJar1rad 2 года назад

    Did you use 2 40 Amp breakers or 3?

  • @biggunsnu
    @biggunsnu Год назад

    How did this pass electrical inspection?

    • @JunkworksGarage
      @JunkworksGarage  Год назад +1

      By following the instructions hooking it up and calling the inspector .

  • @billwatson3527
    @billwatson3527 Год назад

    Just thought I would add if you ever have to change an element you will have to take the unit out of the cabinet. The elements come out of the top of the tubes.

    • @JunkworksGarage
      @JunkworksGarage  Год назад

      i thought i talked about making an access hole i can't remember . etherway i did & actually will have a vid coming out soon on that & cleaning 😁👍

    • @jht09
      @jht09 Год назад

      Will it work if not all elements work at the same time

  • @jht09
    @jht09 Год назад

    I was just wondering if you could leave one of the heating elements unwired and this unit still work properly I don’t want to under size my house would rather over size and I thought I’d I went with the 36 and didn’t need it if I would just leave one breaker off if it would still work correctly if anyone could answer thanks

    • @JunkworksGarage
      @JunkworksGarage  Год назад +1

      i'm not sure but i think it only kicks the third one on if it senses it needs it, but i do know this one is overkill for my mom's apartment we could have gone smaller.

    • @jht09
      @jht09 Год назад

      @@JunkworksGarage any chance if you know if it pulls all 150amps it’s rated at

    • @jht09
      @jht09 Год назад

      @@JunkworksGarage are you having any issues with having a too big of a unit

    • @JunkworksGarage
      @JunkworksGarage  Год назад

      @@jht09 i haven't had 1 issue with it its working great

    • @JunkworksGarage
      @JunkworksGarage  Год назад

      @@jht09 i don't know but if it does it would only be for a short time i wouldn't think it would pull that the hole time it is heating , but i'm not positive

  • @t.dubbya7000
    @t.dubbya7000 3 года назад

    With 120 amps going to the hot water heater alone is a 200amp service enough for this, plus an AC, stove etc?

    • @JunkworksGarage
      @JunkworksGarage  3 года назад

      its not based on the total amps its based on how often they will be used, there is a calculation that you have to go by I am close to the high side but still within the calculations. I have had all my inspections and have passed . 👍

    • @t.dubbya7000
      @t.dubbya7000 3 года назад

      @@JunkworksGarage I see. Would you happen to remember that calculation?

    • @JunkworksGarage
      @JunkworksGarage  3 года назад

      check out Steve's Stray Stuff you tube channel 125 amp sub panel install

  • @beauregardb6108
    @beauregardb6108 3 года назад +2

    NEVER put teflon paste on a female thread! it pushes up in front of your fitting and plugs your system. Thanks for the Vid!

  • @d4nnie13oy
    @d4nnie13oy 2 года назад

    I think you covered all the do's and don'ts in one video

  • @2busysecretary
    @2busysecretary 2 года назад

    So where is the filter that needs to be cleaned every month? We have had ours one month and I can't locate a filter?

    • @JunkworksGarage
      @JunkworksGarage  2 года назад +1

      i had to put an in line filter on mine but it doesn't have a built in one

    • @2busysecretary
      @2busysecretary 2 года назад +1

      @@JunkworksGarage Ok thanks, the Contractor told me to clean the filter every 30 days. I also have a descaler attached to it.

    • @JunkworksGarage
      @JunkworksGarage  2 года назад

      @@2busysecretary that is probably what he is meaning to clean out the descaler im assuming it builds up with sediment

    • @2busysecretary
      @2busysecretary 2 года назад +1

      @@JunkworksGarage Yes it needs a new filter every 3 to 4 months. Thanks for this video. These videos really help out single women homeowners without calling for expensive help.

    • @JunkworksGarage
      @JunkworksGarage  2 года назад +1

      👍

  • @gatorent.productionbuffrec8797
    @gatorent.productionbuffrec8797 2 года назад

    What gage wire?

    • @JunkworksGarage
      @JunkworksGarage  2 года назад

      cant remember but i know i said it in the vid

  • @JoeyIngles
    @JoeyIngles 2 года назад +2

    So EcoSmart won’t warranty their product unless it’s installed by a pro. But the cheapest pro I’ve gotten an estimate from wants $500 to install it.
    So…that’s more than what a new unit would cost.
    I’ll take my chances.

  • @anthonyjohn5136
    @anthonyjohn5136 9 месяцев назад

    I'm looking at the installation guide and it seems to states 3 sets of breakers and wires for the eco 27. I'm confused lol So did you just get away with 2 sets of is there some misunderstanding and 2 sets are sufficient?

    • @anthonyjohn5136
      @anthonyjohn5136 9 месяцев назад

      Nvm read back into the comments and question was already answered. 3 breakers.

    • @JunkworksGarage
      @JunkworksGarage  9 месяцев назад

      @@anthonyjohn5136 👍

    • @anthonyjohn5136
      @anthonyjohn5136 9 месяцев назад

      @@JunkworksGarage thanks for posting this great video!

    • @JunkworksGarage
      @JunkworksGarage  9 месяцев назад

      @@anthonyjohn5136 👍

  • @43wagonwheel
    @43wagonwheel 10 месяцев назад

    Feeds cold water into the tank? I thought this was tankless.

    • @JunkworksGarage
      @JunkworksGarage  10 месяцев назад

      it has small tubes that fill with water were the heat coils are

  • @runswithsisors1753
    @runswithsisors1753 3 года назад

    why would you heat hot water? I's a water heater

    • @JunkworksGarage
      @JunkworksGarage  3 года назад +1

      THAT'S WHY I TITLED IT WATER HEATER INSTAL

  • @bucketlistracing484
    @bucketlistracing484 Год назад

    Please explain why you would want to heat hot water? News flash it's not a hot water heater it's a water heater!

    • @JunkworksGarage
      @JunkworksGarage  Год назад

      news flash old joke nobody cares & those that do are petty little napoleons.

  • @prcoqui51
    @prcoqui51 2 года назад

    Shortcuts, shortcuts, shortcuts, they eventually cause you some problems......should have done the job with the correct materials.

    • @JunkworksGarage
      @JunkworksGarage  2 года назад

      I DID IT TO CODE AND PASSED SO YOU MUST BE DOING IT WRONG