@@rishimaurya5659 sir ji 1 question new outdoor hai 2 ton ka aur 2000 liter ka chiller banana hai ismai kitne no ki chapliery aur kitne feet lage GE jisse colling acchi ho plz replay me
For 1.5 ton unit , if inlet water temperature 30 degree C ,water quality 2000 liters , environment temperature 35 degree C then it will 85 hours to reach 12 degree C water temperature.
Bhai 2000 liter ke chiller mai 3 ton ke compressor se kitni der mai pani bilkul chilled ho jayga grmiyo mai? or mera 3 ton ka compressor hai 3-4 ghnte continue chalne ke baad 2- 2.5 ghante ki trip le leta hai kya ye normal hai? Mai ek baar tank 1200 liter khali krne k baad waps se full krke chalata hu.. please help. Mera compressor Copeland company ka hai . outdoor same apki video jesa hi h skoda ka.
You can use AC compressor also....there is only deference in COP..... Rotary compressor coefficient of performance (COP) is lower then reciprocating compressor.....and little deference in maximum environment temperature operation. Example: reciprocating compressor easily run if environment temperature reach above 50 degree C but rotary compressor start triping......majority of compressor.....will not trip if lower cooling coil load .
Sir aapki baat se mai sahmat hu, mujhe ye pata hai ki pahle liquid line ko open kiya jata hai... Lekin uss time ye kaam mere sahyogi kar rahe the mai video bna raha tha,... Apke comment k liye apko bahut bahut dhanyavad
Bhai second hand air conditioner ka outdoor Lekar banaa sakte he kyaa Kitna kharcha aaye ga . 500 litre water tank ke liye banaa hai .garmi aane wali hai to free me sabhi log pani pi sake
Ab wo to outdoor par depend karta hai, Yadi apko outdoor mill jata hai to uske baad ydi aap khud banate hai to 5000rs alag se kharcha aur aayega... Ydi kisi aur se banwayenge to outdoor k alawa 8 se 10hajar ka aur kharcha aa jayega
यदि पानी आउटडोर में चला जाता है तो उसे फ्लश करते समय गर्म करके पानी को निकाला जा सकता है। लेकिन यह पानी आउटडोर में पहुंचने से पहले कंप्रेसर में जाएगा जिससे आपका कंप्रेसर खराब हो जाएगा। यदि कंप्रेसर में पानी चला जाएगा तो कंप्रेसर को किसी भी स्थिति में नहीं बचाया जा सकता है।
जी सर आरो चिल्लर प्लांट में रोटरी कंप्रेसर लगा सकते हैं या नहीं आरो चिल्लर प्लांट में कौन-कौन सी पाइप यूज़ करना चाहिए 1/4 .3/8🤔 या 1/4 . 1/2 500 लीटर मैं 1000 लीटर डेढ़ हजार लीटर 2000 लीटर में कितने कितने फुट pipe लगेंगे
500ltr , 1000ltr, 2000ltr me Outdoor se cooling coil ko jodne k liye 1/4" aur 1/2" ka pipe use hota hai.. Cooling coil ke liye 3/8 ka pipe lagayen... Capillery size 55n. Lenth 2.5fit × 2
kuch naya sikh ne ko mila 😯
Bohat acha video bnaya h bhaiya
🙏🏽Very nice explain your the best thanks so much 👍🏽
Good 👍
Good information sr
First commenter
Jab koi puchta h to jabab kyu nhi dte ki like subcribsen bus chaiye .....
Kya puchhe ho bhai jiska jbab nahi mila....
Solar se chalne wala dc chiler ki jaankari dijye
Chiller co coldroom ke liye use kr sakte hai ky ?
.pagal ho gya kya 😂 nhi kar sakte Aisa 👋🏻
Kiya sir ji new outdoor mai bhe capleriy lagna zaruri hai
Iss machine me capillary outdoor me nahi lagata hai,
@@rishimaurya5659 sir ji 1 question new outdoor hai 2 ton ka aur 2000 liter ka chiller banana hai ismai kitne no ki chapliery aur kitne feet lage GE jisse colling acchi ho plz replay me
I'm an hvac engineer pl ask questions if dont mind.
4000litre ke liye mujhe kitan pipe use krna hoga aur kon si capilary use krni hogi
12 degree temp lane ma kitna samaye lagega?
For 1.5 ton unit , if inlet water temperature 30 degree C ,water quality 2000 liters , environment temperature 35 degree C then it will 85 hours to reach 12 degree C water temperature.
@@Dhaka1329saniyede 15 , 20 litre akan bir suyu 26 dereceden 15 dereceye düşürmek mümkün mü balık çiftliği için lazım
Bhai 2000 liter ke chiller mai 3 ton ke compressor se kitni der mai pani bilkul chilled ho jayga grmiyo mai? or mera 3 ton ka compressor hai 3-4 ghnte continue chalne ke baad 2- 2.5 ghante ki trip le leta hai kya ye normal hai?
Mai ek baar tank 1200 liter khali krne k baad waps se full krke chalata hu.. please help.
Mera compressor Copeland company ka hai . outdoor same apki video jesa hi h skoda ka.
Hi bhai numver dena aap
How much capillary tube did you used
Isko bhi gas stor karte hai
Sir ye 2000 litre kitne hours me 12 degree temp aa jayega
han meraaj ko aagyi
3000lt. Ke liye kitna copper pipe and capillary lage ga
Sir ji esme Gas fridge wali dalenge ya Ac wali
R22 kiski gas hoti hai, ??
Wahi padegi.
Sir 5/8 pipe ka lenth kitna fit hona chahiye?
Discharge line s hlki gas release krke suction line s pressure nikl do to pipe ko vacuum nhi krna pdega
Good 👍
bhaiya isme ac ka outdor lg skta h kya
Ji bilkul, but compressor alg hota hai,
You can use AC compressor also....there is only deference in COP.....
Rotary compressor coefficient of performance (COP) is lower then reciprocating compressor.....and little deference in maximum environment temperature operation.
Example: reciprocating compressor easily run if environment temperature reach above 50 degree C but rotary compressor start triping......majority of compressor.....will not trip if lower cooling coil load .
Outdor me toh pehele caplari majut tha ? Firse kya panime coil ke sath lagana hai ?
ruclips.net/video/AjfR2RYyFZI/видео.html
एक बार इस वीडियो को भी देख लीजिए शायद आपके सवालों का जवाब मिल जाए
દસાડા. અવસર. વોટર. ગુજરાત
First let's open the valve of the liquid line. After that the valve of the suction line is opened.
Sir aapki baat se mai sahmat hu, mujhe ye pata hai ki pahle liquid line ko open kiya jata hai...
Lekin uss time ye kaam mere sahyogi kar rahe the mai video bna raha tha,...
Apke comment k liye apko bahut bahut dhanyavad
Mumbai me ek acche technesion ki zarurat he
Sir kitane. Ghante me 2000 liter Pani Thanda hoga
3 se 4 ghante me pani thand ho jata hai.
Sir 2 ton ka machine me 130 fit pipe laga h but sussion nhi ho raha h
sussion ka kya matalb hai...
Cooling nhi ho raha h
Suction line cool nhi ho raha h aur discharge pr ice aa raha h and back pressure 60 h and stand pressure 140
Back pressure kya hai, aise me refrigerant kam ho sakta hai
@@farhankhan-ie4ch mere chiller me upar ka hissa ka pani thanda nhi ho pa rha hai
3/8 hi pipe honi chahiye kya
Best cooling ke liye yahi lagega
Gajab
Bhai second hand air conditioner ka outdoor Lekar banaa sakte he kyaa Kitna kharcha aaye ga . 500 litre water tank ke liye banaa hai .garmi aane wali hai to free me sabhi log pani pi sake
Ji bilkul bn jayega
500ltr k 1.5 ton second hand outdoor le lijiyega, jisme resiprocating compressor laga hona chahiye
Kitna kharcha aayega second hand outdoor unit or copper coil leke banvane mein
Ab wo to outdoor par depend karta hai,
Yadi apko outdoor mill jata hai to uske baad ydi aap khud banate hai to 5000rs alag se kharcha aur aayega...
Ydi kisi aur se banwayenge to outdoor k alawa 8 se 10hajar ka aur kharcha aa jayega
Kuch samay baad Tanki ke andar pipeline leakage Ho gai to bahut sara Pani outdoor mein chala jaega uska kya upay hai😮😮
यदि पानी आउटडोर में चला जाता है तो उसे फ्लश करते समय गर्म करके पानी को निकाला जा सकता है।
लेकिन यह पानी आउटडोर में पहुंचने से पहले कंप्रेसर में जाएगा जिससे आपका कंप्रेसर खराब हो जाएगा। यदि कंप्रेसर में पानी चला जाएगा तो कंप्रेसर को किसी भी स्थिति में नहीं बचाया जा सकता है।
New chiller me kitna kharcha aayega
Apke water tank ki capecity kya hai
Sir 200 ltr me kitana kharcha ayega
25k se 30k Ke bich
Bhai ismein kya size ka pipe Dala aur Iske Jo Chhota wale pipe nikale capler ke vah kya size hota hai vah batana Jara aap mujhe
भाई आपने जो सवाल पूछा है वह वीडियो में साफ-साफ बताया गया है.
Kaha se ho ap
Ghazipur UP se
@@rishimaurya5659 are bhaiya mera 2 ton ka chiller krb ho gya compressor fat gya
Ye kaise ho gya, usame kaun sa gas tha,
2000 liter ka chiller kitne price mai lagega brother... Full setup bro
Only chiller ya fir RO v lagwana hai
Only chillar ka price ???
@@rishimaurya5659please suggest me brother
45k to 50k tak lag jayega.....
@@rishimaurya5659 thank you bhai
20days mein coil kharab ho jayega it is failure experience
But jaha maine isko Instal kiya hai, 2 mahine ho gaye avi v chal rha hai.
1/2 ka pipe lagao
जी सर आरो चिल्लर प्लांट में रोटरी कंप्रेसर लगा सकते हैं या नहीं
आरो चिल्लर प्लांट में कौन-कौन सी पाइप यूज़ करना चाहिए 1/4 .3/8🤔 या 1/4 . 1/2
500 लीटर मैं 1000 लीटर डेढ़ हजार लीटर 2000 लीटर में कितने कितने फुट pipe लगेंगे
500ltr , 1000ltr, 2000ltr me
Outdoor se cooling coil ko jodne k liye 1/4" aur 1/2" ka pipe use hota hai..
Cooling coil ke liye 3/8 ka pipe lagayen...
Capillery size 55n.
Lenth 2.5fit × 2
@@rishimaurya5659 kya Ham rotary compresser use kar sakte hain plant ke liye
Nahi kar sakte hai
Yadi aap rotary compressor use karna chahte hai to, 500ltr tank ke liye 2ton ka outdoor use kijiye
Online chiller kaise kare
Hello
Kitna karch ata hai ye banane me
50000 se 60000ra tak
Empier Kitna lega sar
9 se 10amp
15se16
2 tan ka hai
2 ton ka hai to 12 se 14 amp lega
Capillary data kitna ka ha
For 1.5 ton unit 0.064 in capillary 48 in best for maintaining 10 degree C temperature
Ek vacuum pump to rakh lete
Data send kardo bhaiya more please
Pls sir video ka Data send kijiye.
Video ko pura dekhiye, sara data bata diya hai.
Thanks
Don't use thread tape, it's causes problem
Bhai no. Kaya apka
આપકા મો બાઈલ નંબર
Contect no kya h
Temp kese control hoga btaya hi nhi bkwas video😅😅
Lite itna rahta hi nahi hai ki pani thanda ho paye,
Jab pani thanda hi nahi ho pa rha hai to fir temp control karne ki kya jarurat hai.....
Si r apna mob no do
Mujhe apna contact no send kare mujhe chiller tank ke bare me puchhna
Aapka number chaye tha
Sir aapka number milega
App number send karo
Data send kardo bhaiya more please
Data send kardo bhaiya more please
Data send kardo bhaiya more please
Data send kardo bhaiya more please
Data send kardo bhaiya more please