How a Two Stage Furnace Works

Поделиться
HTML-код
  • Опубликовано: 28 июл 2024
  • How a two stage furnace works. What makes a two stage furnace any different than a regular furnace? Are the components any different? In this video I go over what a two stage furnace is, how it works, and what extra or different components it has.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🔥 Furnace Repair Playlist:
    • Furnace Playlist
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    For More Repair Videos:
    🔌 Dryer Repair Playlist:
    • Dryer Playlist
    🧺 Washer Repair Playlist:
    • Washer Playlist
    ❄️ AC Repair Playlist:
    • Air Conditioner Playlist
    💧 Water Heater Playlist:
    • Water Heater Playlist
    🛠️ HVAC Tools Playlist:
    • HVAC Tools
    🔋 Capacitor Playlist:
    • Capacitor Playlist
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    📝 Furnace Parts Reference List:
    Furnace Filters 6 Pack: amzn.to/2SyXT6F
    FM55 Motor Bracket: amzn.to/2RrcZKh
    409 Hot Surface Ignitor: amzn.to/2DdKXiq
    402 Hot Surface Ignitor: amzn.to/2Q69tVp
    Universal Nitride Ignitor Kit: amzn.to/2CS5msj
    Universal Nitride Ignitor: amzn.to/2Ddn2zv
    Flame Sensor: amzn.to/2Js4POT
    1/4 HP Blower Motor: amzn.to/2yGiUnM
    1/3 HP Blower Motor: amzn.to/2SygVKH
    1/2 HP Blower Motor: amzn.to/2RsBdUB
    3/4 HP Blower Motor: amzn.to/2Q6auNd
    5 uF Oval Capacitor: amzn.to/2Rt1LoF
    7.5 uF Oval Capacitor: amzn.to/2Q7YkTU
    10 uF Oval Capacitor: amzn.to/2SwMXGT
    15 uF Oval Capacitor: amzn.to/2JsAdgk
    Carrier 80% Inducer Motor Kit: amzn.to/2Q8cdBE
    Carrier 90% Inducer Motor Assembly: amzn.to/2RoeCZi
    Goodman 80% Inducer Motor: amzn.to/2JtWMRy
    Goodman 90% Inducer Motor: amzn.to/2Q8nd1Z
    Trane 80% Inducer Motor: amzn.to/2SyH4Jo
    Trane 90% Inducer Motor: amzn.to/2Q6b8u7
    3" Hi-Limit Switch: amzn.to/2Svmg5j
    Small Hi-Limit Switch: amzn.to/2Q2vtjU
    Honeywell Gas Valve: amzn.to/2yGvB20
    Round Digital Non-Programmable Thermostat: amzn.to/2JsIsc2
    Basic Honeywell Programmable Thermostat: amzn.to/2JqEjFy
    Nest Thermostat: amzn.to/2qlCgds
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🛒 For a Complete List of Tools and Parts Visit my Amazon Page:
    amzn.to/2Q3QTOA
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🅿️ Want to Support This Channel? You can donate via PayPal:
    www.paypal.com/cgi-bin/webscr...
    👨‍💻 Or if You Believe Crypto is the Future:
    Bitcoin: 3Lor4QqqExtScgkuHkNffJJksVXM5cq1mM
    Ethereum: 0xb981484980b36d5d1b5d6574f3c5bfd73c19e13f
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🙋🏻‍♂️ Word of Advice TV Social Media:
    Facebook ► / wordofadvicetv
    Instagram ► / wordofadvicetv
    Twitter ► / wordofadvicetv
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    📷 Interested in What Gear I use to Film my Videos?
    Sony A6300 16-50mm: amzn.to/2OmLSPF
    Sony 35mm Fixed Lense: amzn.to/2LPAU3A
    Extra Batteries: amzn.to/3c8QBj1
    Memory Card (2): amzn.to/34rcwQ1
    60" Tripod: amzn.to/2mLXrU0
    Bird-Eye View Tripod: amzn.to/3b3RWYy
    Rode VideoMicro Microphone: amzn.to/2Ol9KDp
    Rode Wireless Go Microphone: amzn.to/3ed5Wkv
    Neewer Halo Light (2): amzn.to/2LTANUK
    Viltrox LED Light Panel: amzn.to/39ZbSu4
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    🙏 We would greatly appreciate it if you considered supporting our channel while shopping on Amazon by buying anything you need on Amazon after clicking on one of the links above. This gives us a small commission at no additional cost to you and helps us continue producing more videos! Thanks a million for your support!!
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    ⚠️ Disclaimer:
    This video is for educational purposes. All appliance and HVAC repair work should be done by a trained professional. Word of Advice TV is not responsible for any possible damages or injuries caused by the use or misuse of the provided information.
    ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
    📥 SPONSORS / Collabs:
    Would you like to partner with Word of Advice TV? 🤝
    Email: WordofAdviceTV@gmail.com ✍️

Комментарии • 167

  • @rdcleaners
    @rdcleaners 5 лет назад +7

    Just subscribed and watched a bunch of your videos. You do an awesome job, right to the point, thanks!

  • @jdubya54
    @jdubya54 Год назад +1

    Almost every time i search for information, one of your videos shows up. Thanks for all you do making videos

  • @Gary-xk3qc
    @Gary-xk3qc 6 месяцев назад +2

    Thank you young man for the information. Regarding two-stage furnaces you educated a 70 year old man

  • @Rayram555
    @Rayram555 5 лет назад +2

    You are a real good at explaining the furnace and very articulate . Thank You

  • @alkodhanani3018
    @alkodhanani3018 4 года назад +3

    Thanks Jay, for your extraordinary guidance. I've used your videos to help me fix my furnace twice and both times I remembered your goodwill and selflessness.

    • @WordofAdviceTV
      @WordofAdviceTV  4 года назад +1

      You're welcome! I appreciate your kind words and am happy to hear that my videos have helped you fix your furnace! Stay warm! :)

  • @ioreodream
    @ioreodream 2 года назад +1

    That was great. I work for a large thermostat company and I found this helpful with my learning. Also, I love the NFS 3 soundtrack! Great memories playing knock-out with the F355 on that game.

  • @jasonssmith1991
    @jasonssmith1991 3 года назад +3

    Man I love your videos. You give the best advice man. I always look forward to learning from you man. Thank you so much for all the advice you share!!!!!

  • @nelsonm5032
    @nelsonm5032 4 года назад +4

    just got a two stage, great explanation! thank you!

  • @RayRay-nb7tn
    @RayRay-nb7tn 5 лет назад +6

    Good explanation on this thank you.

  • @binfordtoolman5674
    @binfordtoolman5674 Год назад +2

    Nice vid! Right to the point and clear explanation in simple terms. Wish more would follow your lead.

  • @marknagy5892
    @marknagy5892 3 года назад +2

    You guy are an awesome teacher no doubt.

  • @hchehrehnegar
    @hchehrehnegar 5 лет назад +1

    Great video.the guy is very knowledgeable.

  • @Dave-nm3xc
    @Dave-nm3xc Год назад +1

    Thanks for an excellent explanation.

  • @ronaldcach2779
    @ronaldcach2779 5 лет назад +2

    Great one again THANKS FRIEND

  • @AndresH92
    @AndresH92 5 лет назад +7

    Great video 👍

  • @AdnanKhan-ky3jp
    @AdnanKhan-ky3jp 5 лет назад +2

    Great info, thanks.

  • @enduringpromise
    @enduringpromise 3 года назад +2

    FYI, the second stage is more efficient but it short runs which means less humidity is removed making the occupants feel less comfortable and it also is more wear on the furnace parts. In the north high efficiency is more cost effective. I just learned this from another great teacher.

    • @CaesarCapone
      @CaesarCapone Год назад +1

      I believe you're talking about removal of heat (A/C), whereas this guy is talking about addition of heat (furnace). Removal of heat also removes moisture, addition of heat often coincides with addition of moisture (humidification).

  • @edf.847
    @edf.847 4 года назад +1

    very good explanation sir

  • @surujnarinepundit137
    @surujnarinepundit137 3 года назад +2

    Your videos are great, it helps me a lot. Can u do a video to why a two stage furnace will not go into high fire. Thank you

  • @damian43
    @damian43 3 года назад +1

    awesome vids, thanks form argentina buenos aires.

  • @rodolfosontay978
    @rodolfosontay978 5 лет назад +1

    Great video thanks

  • @sneakyquiet414
    @sneakyquiet414 4 года назад +5

    It would be great if you have a tutorial on wiring a 2stage unit compressor , condenser & thermostat

  • @mansouralhanoun8358
    @mansouralhanoun8358 3 года назад +1

    Love your videos

  • @toddyfrancis9903
    @toddyfrancis9903 3 года назад +2

    Thanks for your video, it's very informative and educational! I have a single-stage furnace, is it practical or economical, or doable to convert it from a single to dual-stage? and is there someone doing that? Thanks for your reply.

  • @oglerdeleon9494
    @oglerdeleon9494 5 лет назад +2

    Thanks for the education brother!!

  • @onlywenilaugh6589
    @onlywenilaugh6589 10 месяцев назад +1

    Thanks for explaining. More to go wrong on the heart of the home. I like single stage 80% furnaces. May gas bill is about $55 a month so 20% savings if I were to get that from two stage, would take quite a while to make up for the added cost and repair bills. Just my opinion.

  • @WakeUpAmerican000s
    @WakeUpAmerican000s Год назад

    Hello Jay. Thank you for the informative video. It seems to me that certain thermostats would not work well with two-stage. For example, the Google Nest, which requires at least 1.5 degree delta from the set point before it turns on. (can't be adjusted - many online complaints about this). For the low-fire position to answer the call, seems to me that a 0.5 to 0.7 degree delta from the set point would be more effective at firing the furnace in time for the low-fire can satisfy the demand. (most of the time ...)

  • @enzoamore9173
    @enzoamore9173 5 лет назад +2

    Can you do videos on hydronic atmospheric natural gas boilers we have a ton of these in the Northeast region and your videos really help me learn gas as I do mostly oil burners. Thanks

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +1

      Sorry Enzo, but I don't work on enough boilers to be able to give sound advice on them. I mostly service residential forced air furnaces so that's why all my videos only talk about them.

  • @am1manTravel
    @am1manTravel 5 лет назад +1

    Thanks!

  • @doncocorote1
    @doncocorote1 5 лет назад +3

    Nice 👍 I like yours videos, Can you do a video reading a schematic?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +2

      Thank you! That is a good idea! I have a long list of videos to make but I will add that to the list as well.

  • @DrRChandra
    @DrRChandra 3 года назад +2

    What do furnace controller boards expect? What I want to know is, if I want to go into stage 2, is it sufficient to connect the stage 2 circuit, or would I have to connect both the stage 1 and stage 2 circuits? What I want to do is have a go at writing my own programming using a commercial relay board (think either a network attached relay controller, or a Raspberry Pi with a relay HAT), and want to know which relays I would have to close: if the one would be sufficient or if I have to close both to get the second stage.

  • @asrealasitgets765
    @asrealasitgets765 3 года назад +2

    Any advice on how to connect a 2 stage heat pump to a 2 stage gas furnace? Thanks

  • @ahmadwalidanwary8914
    @ahmadwalidanwary8914 3 года назад

    Thank you

  • @ballkickers7142
    @ballkickers7142 3 года назад +3

    Question . .. How is the connection between the thermostat and the IFC on a two stage furnace?

  • @imun1ty
    @imun1ty Год назад +2

    I have a Goodman GMH80905CN which is a two stage 80%, 80k BTU 4 burners and only have one pressure switch -.75 PF. I don’t turn my thermostat any higher than 58 in my house ya I know that’s cold but I don’t think I have ever heard my furnace kick into the 2nd stage hope I get a longer life out of the heat exchanger? I heard by early 2023 they will phase out 80% furnaces thinking of buying another one for the future don’t like the 90% and greater furnaces at all.

  • @kckc6578
    @kckc6578 4 года назад +2

    Do you have any videos on heat exchangers? I thought I had seen one before but cant find it.

  • @MikeWynn1966
    @MikeWynn1966 2 года назад +1

    When I built my house in 2007 I had a 2 stage gas furnace with a Heat Pump installed, I suspect it was installed as a single stage either at the furnace or in the thermostat. How can I know if my 2 stage was setup incorrectly as a single stage? I am now installing an ECOBEE thermostat and it is indicating mine is single stage. Any Advice? Thanks and great video!

  • @karastom2304
    @karastom2304 4 месяца назад +1

    Thanks so much I did learn a lot from you
    Is 2 stages require 2 pvc pipe also is really save you money and is there parts way too much expensive

  • @fooBar55
    @fooBar55 6 месяцев назад

    Excellent explanation and video. I used to have a one stage furnace and recently replaced with a 2 stage. My main motivation was that with a one stage my family room would go to very high temp quickly (thermostat in hallway) and I was hoping that the 2 stage would heat up the family room more gently and I would not get so much of the high/low of temperature and the low stage would heat more gently. I live in northern California btw. But I did not experience that. When I told that to the Hvac installer he told me that I should have installed a multi-speed if I wanted more evenness. Anyway too late. Recently (2 years later) when told the furnace's technician who had come to fix a minor problem about my unhappiness he checked and said that it was never installed as a two stage but a one stage. So apparently he fixed it but I am not seeing much of a difference.
    2 questions:
    Q1. How do you tell if the 2 stage is correctly configured? E.g see if the heat level coming out of a vent suddenly jumps after 15 minutes?
    Q2. Is it possible to configure the 15 min transition from stage 1 to stage 2 to say 25 minutes. Or better still can the 2 stage be controlled by the difference in temperature (ie temp in room to temp set on thermostat - does the thermostat send this info to the furnace?).. I have a Lenox SL280DFV and a Nest 3rd generation thermostat. The W1 wire is connected BUT there is NO w2 wire (even though they put a brand new wire looks like they did not have enough strands).
    I have a two zone system (both with nest 3rd gen) and a Honeywell HZ322 TrueZone which is suppose to support 2 stage furnace/AC for up to 3 zones

  • @Jon-hx7pe
    @Jon-hx7pe 4 года назад +9

    2-stage does not save fuel, it burns less gas over a longer period of time. It's for comfort.
    Technically the steady state efficiency can be a little lower on low fire but that's offset by fewer on/off cycles so it's a wash.
    You mentioned a 10 minute time delay - if you value your customers, sell them 2-stage thermostats so high is only brought on when it's needed and there's the ability to drop back down to low fire. The whole idea is to get continuous operation in very cold weather.

    • @buer444
      @buer444 2 года назад +2

      DOE and ASHRAE found that 2 stage furnaces use slightly less gas but more electricity, overall slightly more energy.
      Residential Two-Stage Gas Furnaces: Do They Save Energy? Alex Lekov, Victor Franco, and James Lutz Lawrence Berkeley National Laboratory

    • @Jon-hx7pe
      @Jon-hx7pe 2 года назад +1

      @@buer444 psc motors are inefficient on lower speeds. ecms should use the same amount of electricity or less on 2-stage as 1-stage when airflow is kept proportional to heat output. probably less because power goes up by the cube as you try to increase airflow on a given duct system.

    • @buer444
      @buer444 2 года назад +1

      @@Jon-hx7pe Agreed I just wanted to point out that energy saving with a 2-stage furnace is small if any. Almost everyone I have talked to lately has said they bought a 2-stage because it saved money and this video says the same. As it turns out with covid 1-stage is hard to find.

    • @Jon-hx7pe
      @Jon-hx7pe 2 года назад +1

      @@buer444 they get improved comfort especially when properly sized and controlled by a 2-stage thermostat. contractors forget about comfort and noise levels, think the idea is to quickly satisfy and shut down, that bigger is better.

    • @buer444
      @buer444 2 года назад

      @@Jon-hx7pe Again no argument. Two contractors have told me that a two-stage thermostat is a problem in my house. I assume it's a problem with wiring and didn't think to ask more. So the furnace will run 10 or 15 minutes on one and then jump to 2nd stage so I see little advantage in spending $400 more.

  • @dennysmith5284
    @dennysmith5284 Год назад +2

    Increasingly, I see HVACers recommending the ol' 80 furnace, due primarily due to much less service costs over its lifetime vs the >90 efficient furnaces. In essence, over a 20 year life, the argument is that the ROI doesn't work out for 90's, but do work out for the 80's. Can you offer your experience to this? Thanks for all that you do.

    • @RogerPack
      @RogerPack Год назад

      He has a vid on it, he prefers 80 cost wise

  • @severnt
    @severnt 3 года назад +2

    Which inducer motor is that (model) and any idea where to purchase? I have the XV80. I like the format of this inducer motor better than mine with the metal fan in plastic cage.

  • @brianminster1407
    @brianminster1407 Год назад

    Jay great video. I have the exact furnace that is over 20 years old. I believe my gas valve is sticking resulting in misfiring and I am not getting a higher gas flow on stage 2. Can you tell me the model number for that gas valve or a suitable replacement? It’s not visible on my valve. I’m having a difficult time finding it online. Thank you!

  • @enzoamore9173
    @enzoamore9173 4 года назад +1

    Is it normal to see a pilot light slightly lit when not calling for Hot water? If not how should I fix this issue?

  • @florenciohernandez2986
    @florenciohernandez2986 Месяц назад

    Hey man how you doing, I want to thank you for the video it's very helpful, by any chance do you have the diagram of how to wire the 2 stage thermostat from the board.. Thank you, or any of you videos where you explain that..

  • @davidlang4765
    @davidlang4765 3 года назад +2

    What's the difference in thermostat wiring?

  • @reedsteindel1864
    @reedsteindel1864 3 года назад

    I have a two-stage furnace, I bought the new "nest" thermostat. It does not have a lead "w2" just a "W" lead.
    how do I hook it up ? connect the W2 wire to the nest " W" terminal , or just hook up the " W1" lead and spare out the W2 lead from heater ?

  • @NicolasCereghino30
    @NicolasCereghino30 3 года назад +1

    What is the three stages heat pomp?

  • @bettyrichsullenberger3268
    @bettyrichsullenberger3268 3 года назад +1

    what if it seems not to go to the second stage. therostate is turned way up and can only get to 60. thanks

  • @em1103
    @em1103 2 года назад

    Why do you need a different pressure switch for each stage? Is it because the inducer motor speeds up in different stages?

  • @SirThomasHarber
    @SirThomasHarber 2 года назад +1

    Is the 2 stage furnace really more efficient, or does it just maintain more even heating? I've heard stories that a two stage furnace can dramatically increase gas bills.

  • @NicolasCereghino30
    @NicolasCereghino30 3 года назад +1

    What is three stage heating and cooling?

  • @sneakyquiet414
    @sneakyquiet414 4 года назад

    Is there a way wire two stage condenser only bypass 1st stage not cooling enough in high heat 74-78 out vent register

  • @wskripka1
    @wskripka1 3 года назад +1

    Is the Blower Motor TWO SPEED ?

  • @sundersid
    @sundersid 3 года назад +2

    Thanks for the video..I’ve a two stage furnace and condenser.. my nest thermostat has only one wire Y and W.. could the contractor have set this up for a single stage?

    • @excellinc.9951
      @excellinc.9951 Год назад

      Yes , only one stage is working, for the second stage you need Y2 and W2 connected to the furnace

    • @billyhw5492
      @billyhw5492 11 месяцев назад

      Would the furnace itself still work with 2 stages based on timing or algorithm, even if the thermostat only has 1 stage? @@excellinc.9951

  • @thecli
    @thecli 2 года назад

    Hello, I have a Carrier 8000 weathermaker 2 stage furnace, and I would like to know how to wire it up to run only on Hi Stage, the entire time. Could you help me out?

  • @FrugalFixerSpike
    @FrugalFixerSpike 2 года назад

    My Dads to stage, was giving me fits, 3 flash code, 8 to 10 seconds after blower starts, the inducer stops. The only way to make it run is on stage 2 with w2 connected to w1. Any idea why it would do this on w1?? Thanks
    Armstrong 93 gas upright

  • @rrusie3184
    @rrusie3184 Год назад

    I have a 22 year old Ruud stack system that many need replacement (due to a/c compressor short-cycle intermittently furnace ok) with something similar how good is a new Rheem/Ruud complete system?

  • @beatrizlouvado5939
    @beatrizlouvado5939 3 года назад +3

    Do I have to change my thermostat if I change my regular furnace to a two stage furnace? Thanks

    • @DrRChandra
      @DrRChandra 3 года назад +2

      The controller built into some 2 stage furnaces has an option to run with a single stage thermostat. They automatically run at stage 1 for some time, realize they've been in stage 1 for that time, and ramp up to stage 2 until the thermostat no longer calls for heat. Some of them are "intelligent" enough to figure out patterns of usage, and will go into stage 2 faster. Think, for example of typical overnight setback. The furnace "knows" it's been off for say 6 hours. It may wait only 5 minutes of being in stage 1 to shift into stage 2 instead of the "normal" 10 minutes.
      Of course, a multistage thermostat would be even better, because it "knows" that it is trying to heat up e.g. 7 degrees instead of just e.g. 2, so it can go directly into stage 2 to achieve that 7 degrees faster.

  • @timturner413
    @timturner413 Год назад +1

    I used to have a white rogers thermostat that showed when the second stage was firing. Went bad and I put a T5 Honeywell for the Wi-Fi ability. Disappointed that it doesn’t show what stage my furnace is on.

  • @Balticblue93
    @Balticblue93 10 месяцев назад

    Many furnaces control the two or three stages of the firing process. Most current day furnaces do not require a two stage or 3h stage thermostat to control the stages. The System controls the stages with a standard thermostat like Ecobee. Goodman furnaces from 2008 have been doing this for a long time. Carrier, Bryant and ICP are controlled by the board.

  • @christopherfields2015
    @christopherfields2015 4 года назад +3

    I just got a two-stage today and it seems like it just runs a lot? If I set it at 71 it'll hit 71 and just stay there? Guess it is a bit chilly outside in the 20s

    • @Jon-hx7pe
      @Jon-hx7pe 3 года назад +1

      low fire is a maintainer - that's the whole idea, replace the heat that's lost, don't overheat and shut down.

  • @fknbrett
    @fknbrett Год назад

    Have 2 stage Rheem 96V furnace & 1 stage Nest thermostat - read it’s easy to change furnace to one stage but they didn’t say how - can’t find where read that -
    Appreciate any help - Thanx! -

  • @brandonlongle6730
    @brandonlongle6730 3 года назад +3

    Does the 2 stage variable speed work in ac or just heat mode?

    • @angiet2190
      @angiet2190 2 года назад

      I would like to know the answer to this question also. Why doesn't he answer questions

  • @Gonzalezjimmy265
    @Gonzalezjimmy265 5 лет назад +1

    A lil unrelated but why is there limit switch looking things sometimes but on the flu pipe and blower wheel housing?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +2

      The one on the flue pipe is probably a flame roll-out switch. It's there to shut off the furnace if for some reason there is a back-draft and the combustion gases are coming back into the home. (Like in an instance where a chimney cap collapses)
      The blower wheel housing limit is typically just a thermal limit. If for some reason it gets too hot in the blower motor compartment, that limit will interrupt the heat call. A burnt out blower motor can get really hot when it tries to start. That's when you get the burnt electrical smell.

  • @seansethi196
    @seansethi196 Год назад

    Hi, I am having an issue. Why would a furnace not go in to 2-stage anymore? Mine is barely going past 60 F for the last two hours, when previously it used to blast hard. Thank you.

  • @biblebloopers946
    @biblebloopers946 2 года назад

    So you don't need a two stage thermostat with a two-stage furnace? The furnace itself will bring on stage 2 after 15 minutes of run time?

  • @madukabandara6491
    @madukabandara6491 2 года назад

    Hello @wordofadvise,
    My 2 stage systems inducer motor shut-off when high fire pressure switch closes.
    Current diagnosis suggests control relay. How to troubleshoot to confirm if that is the case?
    Other possibilities are that the a) inducer motor is defective in a way that it can not drive at higher speed or b) second stage gas valve not opening. I feel the next diagnostic point need to be the relay in control board though.
    Details:
    2003 Bryant 315aav.
    Cleaned pressure tubing and checked for other air obstructions. (seem not to be the problem)
    Did not had this symptom with older Robertshaw thermostat last year. Symptom present thus year with Sensi WiFi thermostat.
    LED diagnostic show 31 : high heat pressure switch or relay did not close or reopen. Control relay ,may be defective. Refer to code #32.
    Code 32: check for defective inducer motor, pressure switch, low inducer motor voltage, pressure tubing, inadequate air, low inlet gas pressure.

  • @copkhan007
    @copkhan007 9 месяцев назад

    I have 90% furnace. It has a 2 stage honeywell gas valve with 3 wires coming out. It worked fine last year. 6 months ago I installed a Nest TS. Now when i turn on, the ignitor glows yellow but the furnce does not come on. The W1 is connected on tge terminal strip and W2 is not connected. Do i have to jump W1 and W2 in order for 2 stage gas valve to work??

  • @enzoamore9173
    @enzoamore9173 5 лет назад +1

    So the higher the WC rating on the dual pressure switch means low side?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +1

      Lower W.C. rating = low fire
      Higher W.C rating = high fire

  • @louishollandjr
    @louishollandjr 4 года назад +2

    How does 2" Vents works on Furnace Fresh air an Exhaust.

    • @MrTrailerman2
      @MrTrailerman2 3 года назад

      Depending on the btu input and length of pipe including 45's/90's determine the diameter of pipe. There is a table included with the installation guide for every model of furnace that tells you what is required .

  • @jamessimons5744
    @jamessimons5744 2 года назад

    Question: Does the two stage furnace have to wire to the thermostat differently? Or is it still just one single heat wire that goes to the furnace? I have a nest gen 3 thermostat with a Goodman 2 stage furnace. But only one heat wire. Shouldn’t I have a second wire going to my W2 thermostat slot?

    • @excellinc.9951
      @excellinc.9951 Год назад

      Yes , a 2 stage furnace needs 5 wires , the w2 has to be connected to your furnace, only 1 stage is working

  • @UndiscoveredTalented
    @UndiscoveredTalented 5 лет назад +2

    Is there any cons to keeping your furnace in single stage ? Other than it not being able to keep up on colder days

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +3

      As far as I know, there are no cons besides that one :)

    • @UndiscoveredTalented
      @UndiscoveredTalented 5 лет назад +2

      Word of Advice TV okay thank you brotha, I’ll be keeping mine in low stage then lol

  • @alterweinstock9402
    @alterweinstock9402 5 лет назад +4

    What's the difference if you use less Heat but running longer vs more heat running less?

    • @rxonmymind8362
      @rxonmymind8362 5 лет назад

      Shhhh. Smarty pants people get taken away. 😁
      Look I got a two stage only due to the 17 Seer rating vs the one stage 13 that I had.
      It's quieter and that's it.

    • @christopherfields2015
      @christopherfields2015 4 года назад

      Yeah I just got a two-stage today and it just seems to keep runningI know it's really cold outside but it seems like I set it at 71 it'll hit 71 and then go into the slower stage but just keep going, trying to figure how much energy I'll be saving when it seems it take more electricity

  • @BobP68
    @BobP68 4 года назад +6

    Jay, what about the thermostat ? Can a 2 stage run off of a conventional single stage stat? Or does the stat have to be 2 stage as well ?? Thanks.

    • @tbonemoon1330
      @tbonemoon1330 3 года назад

      You can still use a single stage tstat. Just jump W and W2 on the IFC

  • @angiet2190
    @angiet2190 2 года назад

    Is a two stage only good if u have gas furnace. What about a heat pump

  • @mae2759
    @mae2759 Год назад +1

    Do you need a different thermostat for a 2 stage furnace compared to a 1 stage?

  • @hzwg3542
    @hzwg3542 6 месяцев назад +1

    We just have a problem with a 2 stage gas furnace (Trane VX80) which is wired to a one stage thermostat. The 2nd stage is supposed to be one if heat is called for more than 10 minutes. However, it is never one and the furnace keeps running in 1st stage nonstop because set temp. cannot be reached. I measured the Hi terminal on the gas valve and it is never energized. Can the control board be bad? Any idea will be appreciated!

    • @WordofAdviceTV
      @WordofAdviceTV  6 месяцев назад +1

      Sorry to hear about the furnace troubles! Does your control board have little dip switches on it? Your furnace manual should have instructions on what each switch is for and in which setting it should be. (if you don't have the manual, you should be able to look it up online) A few of those switches may be related to the two stage options and they are in the wrong position. It could be a bad control board too. This one is a bit challenging to guess without being there..

  • @mike6636
    @mike6636 3 года назад +2

    I bought 2 stage multispeed goodman GMEC961005cn recently. Its blower shuts off right away when fire goes off although ductwork is quite hot. Thermostat reach and maintain desired temperature too. Looks like more on and off cycles. Blower suppose to stay on for 2-3 min after fire shuts off. Heater fan delay dip switch is ON. Most of other dip switches are ON with no luck yet. What could be problem and fix if anybody face same problem?

    • @excellinc.9951
      @excellinc.9951 Год назад

      GMEC961005CN is not a 2 stage furnace, it’s 1 stage gas furnace

    • @mike6636
      @mike6636 Год назад

      We figured it out. Thermostat wiring was wring.

  • @Rokutarox3TV
    @Rokutarox3TV 5 лет назад +1

    How many heat anticipators are in a 2-stage?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +1

      Do you mean the heat anticipators in the thermostat? Or is that a different name for the hi-limit? If you are talking about the fan limit/hi-limit, there is just one.

  • @davenone7312
    @davenone7312 3 года назад +7

    So the 2 stage furnace will run for 15min at low stage while a single high stage would have got the same job done in less than half that time, so where's the savings?

    • @MrTrailerman2
      @MrTrailerman2 3 года назад +2

      It's all about time and volume of gas usage. It may satisfy the call for heat at 60% thus reducing the gas consumption. Remember you are billed at how many revolutions the meter completes in a billing cycle and by reducing (slowing the meter) will reduce the bill.

    • @enduringpromise
      @enduringpromise 3 года назад

      The savings is not there. The longer run time is to reduce short cycles and to remove humidity which improves comfort. Short cycles would cause more wear and tear.

    • @WakeUpAmerican000s
      @WakeUpAmerican000s Год назад +2

      The theory is that you increase longevity of the furnace heat exchanger by fewer extreme heat-cool cycles, and longer run times for the fan. This also decreases the amplitude of the sine-wave you get when you plot the temperature in your home: the two-stage doesn't let the house get as cool. And when it runs, it runs very quietly. No whoosh when the furnace fan kicks in.
      Keeps the home more comfortable. Does that save energy? Depends on the particular installation, the thermostat used, the outdoor temperature, and the home's ducts.

    • @Bajaheat
      @Bajaheat Год назад +1

      Yea a blast of hot heat and big temperature swings are great, enjoy your single stage

  • @idealdirecthomeimprovement1639
    @idealdirecthomeimprovement1639 3 года назад +1

    800th person to like! Great video!

  • @robertkent4192
    @robertkent4192 3 года назад +1

    i have a 2 stage furnace it never goings into the second stage

  • @ClayArn
    @ClayArn Год назад

    Sorry, but I am hoping for a little help.
    I need to replace the motherboard in my unit, but can't seem to find the part.
    I am looking for the OEM, Generic and the Refurbished versions.
    My unit is a Luxaire Model FL9T080B12UP.
    If you happen to know how I can get the part numbers for each type of board, I would really appreciate it.

  • @gregw.3947
    @gregw.3947 17 дней назад

    If the pressure switches are .17 and .5 inches of water then the ratio is (.17/.5=.34) so how does stage one reach 65% of max output? Thanks in advance.

  • @youngamazin2010
    @youngamazin2010 5 лет назад +2

    Question.... do I need a different thermostat?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +2

      Usually no. The control board takes care of the staging aspect of it. Although there are 2 stage thermostats out there..

    • @Lenser
      @Lenser 4 года назад +2

      @@WordofAdviceTV I have a 2 stage furnace and and ecobee which has a W-2 terminal. The terminal block on the furnace controller where the thermostat wires connect to doesn't have a w2 terminal for the w2 from the ecobee to connect to. How can the ecobee w2 control the second stage on the furnace?

  • @rej1748
    @rej1748 5 лет назад +1

    Can you do fireplace as well

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +1

      Unfortunately I do not have a fireplace. Maybe later on I can make a video with someone else's. Thanks!

    • @rej1748
      @rej1748 5 лет назад +1

      @@WordofAdviceTV thanks buddy

  • @lancerudy9934
    @lancerudy9934 3 года назад +1

    How does a 2stage thermostat work.

  • @liyuanshi2377
    @liyuanshi2377 5 лет назад +1

    Why is the dirt pocket on your furnace so long?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +1

      I bought the house 2 years ago and that's just the way it was :)

  • @JohannnesBrahms
    @JohannnesBrahms 5 лет назад +4

    Seems like the newer furnaces with 2 stage operation would have more components to break down. Also the silicone carbide igniter is easily broken and would need to be replaced. The energy savings is negated by the cost of repair when it breaks down. Older furnaces with fewer and simpler parts like a spark igniter and one stage operation might be minimally less efficient but will probably need fewer repairs.

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +3

      Sounds about right :) If nothing breaks down then they do turn out to be more efficient. But since the gas valve and inducer for example are 2 stage like you said, whenever they need to be replaced, they are more expensive. I wonder if anyone sat down and did the math to see if the savings are worth the initial extra cost and further maintenance.

    • @JohannnesBrahms
      @JohannnesBrahms 5 лет назад +3

      @@WordofAdviceTV Then there is the time/energy use factor to consider. It would seem logical that if you run a one stage furnace at full capacity on days that it is less cold outside, then it would not have to run as long as a two stage operating on half capacity. It is all about when the thermostat is satisfied and turns off the gas. Just sayin!

    • @elgringoec
      @elgringoec 5 лет назад +2

      @@JohannnesBrahms
      Exactly. Add to that the blower motor operating longer increases electricity use. Quieter operation could be the advantage to low mode.
      If I were designing the control system, I would have it sense the difference between the set temperature and the temperature outdoors and select mode based on that difference.

    • @tomking1890
      @tomking1890 5 лет назад +3

      I have had a 2 stage Trane for 8 years with no service calls. On stage one you can hardly hear the blower.

    • @JohannnesBrahms
      @JohannnesBrahms 5 лет назад

      @@tomking1890 That is not unusual for a modern furnace. It is when it gets older that the problems might occur. More operating parts equal more opportunities for things to go wrong. Personally, I don't believe that a two stage unit provides any more value than a traditional one stage. Just my opinion.

  • @NicolasCereghino30
    @NicolasCereghino30 3 года назад +1

    What is stage three heating and cooling system for the gas thermos?

  • @yesitsmonkey
    @yesitsmonkey 5 лет назад +1

    Hi, I am getting lots of good information from your work. And I have found other peoples videos that checking gas pressure using manometer? I have recently replaced my two-stage furnace but I didn't see anything that is my HVAC technician checked low or high-pressure test. I use LP gas, I saw he did convert natural gas to LP and changed spring but I didn't see him checking the pressure. Is it ok not checking the pressure? Or do you think I should check it? Can you make a video on how to adjust two-stage furnace using natural gas and LP gas? I do not have manometer, is there a way to check high and low LP gas pressure?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +2

      You cannot check gas pressures without a manometer (as far as I know). Most of the time the new gas valve will come factory set to the right levels.. But he did put in a conversion kit so that may have slightly affected it. Did he do a carbon monoxide test in the flu? Also, if the flames are looking pretty sharp and not lazily licking the sides of the burner face plate then most likely it is good. Of course it's always better to check but not mandatory..

    • @yesitsmonkey
      @yesitsmonkey 5 лет назад +1

      @@WordofAdviceTV yes the flames are looking pretty sharp. And I checked the carbon monoxide test using a carbon monoxide detecting device that I can buy from HomeDepot. I lay it down that device just below the furnace and the device didn't react. However, since the furnace is in my attic, I put carbon monoxide detecting alarm device on the floor. Since carbon monoxide is heavier than air, I assume that if the gas leaks from the attic it will fall down to lowest place first. Thanks for your help and I wish many people will get better educated about HVAC systems.

  • @jazzfan7491
    @jazzfan7491 7 месяцев назад +1

    I have a two stage heat pump

  • @mystique0417
    @mystique0417 5 лет назад +2

    Are there 2 stage 80% furnaces?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +1

      The one in the video is a good example of just that lol :)

    • @coolramone
      @coolramone 4 года назад

      I have one (I think). An AS Heritage 80

  • @StevePittinger
    @StevePittinger 5 лет назад +1

    Does the 2 stage use the same thermostat? Seems like a call for heat would be the same regardless of how long it takes the furnace to get the temperature there.

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +1

      I totally forgot to talk about the thermostat. Oops.. But yeah, my thermostat has w1, w2, y1, and y2 terminals for two stage operation.

    • @petertams394
      @petertams394 5 лет назад +1

      Word of Advice TV why y1 and y2. Isn’t that cooling ?

    • @WordofAdviceTV
      @WordofAdviceTV  5 лет назад +2

      @@petertams394 There are 2 stage air conditioners as well

  • @sergiodoordie319
    @sergiodoordie319 4 года назад +1

    Good but u didn't shove how to wire it cuz on the board u got w1 and w2

    • @WordofAdviceTV
      @WordofAdviceTV  4 года назад +1

      Yes, I did forget to talk about that part. Thank you for bringing it up! On some units, the thermostat will be the component responsible for switching the furnace to high stage. (in that case, w1 and w2 would need to be wired separately) But on my unit, w1 and w2 are jumpered and the control board is the one that switches the furnace to high stage via a timer.

  • @RogerPack
    @RogerPack Год назад

    I think two stage furnaces have blowers with two stages, yes?

  • @edt.5118
    @edt.5118 Месяц назад

    What is the best 80% efficiency furnace? The life expectancy of high efficiency furnaces is only 15 year.

  • @TeslaBoy123
    @TeslaBoy123 2 года назад +1

    Meanwhile I looking same extra wood for my fireplace bcz winter are around corner 🤣

  • @aliahmed-tz4pf
    @aliahmed-tz4pf 2 года назад +1

    In summer time. How is two stage work

    • @aliahmed-tz4pf
      @aliahmed-tz4pf 2 года назад

      When the ac running is the. Fan Motor work slow for 15 minutes the. Higher the speed after the 15 minutes or gust for heat