WORST GAS BOILER TO INSTALL IN THE UK ? Glow-Worm Micracom combination boiler part 1.

Поделиться
HTML-код
  • Опубликовано: 28 май 2024
  • Derek in this video takes us through the process of installing the cheapest boiler he could find on the day the Glow-Worm Micracom and asks is this the worst gas boiler to install in the uk.
    • What is the cheapest g...
    Buying the boiler and unboxing video

Комментарии • 51

  • @julianwebb8712
    @julianwebb8712 Месяц назад +10

    I wouldn’t trust that turbidity tube thing as obviously a sample from the top of a rad will be vastly different to one from the bottom as iron doesn’t float 😂

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад +1

      The magnetite would be in suspension in the water so it makes no difference taking the sample from the top or the bottom of the radiator

    • @julianwebb8712
      @julianwebb8712 Месяц назад

      @@tomkatgastraining Can’t agree with that……if magnetite were held in suspension it wouldn’t block systems making Powerflusing necessary. It would leave the system during a regular drain down

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад +2

      @@julianwebb8712 if it wasn’t in suspension how dose the magnet in the filter collect the iron or is it just witchcraft?

    • @julianwebb8712
      @julianwebb8712 Месяц назад

      @@tomkatgastraining There is a difference between held in suspension and carried in the flow…..when the forced circulation stops the magnetite sinks, iron doesn’t float unless it’s Titanic shaped 😛

    • @julianwebb8712
      @julianwebb8712 Месяц назад

      But anyway, if it was always a sealed system then it was likely to be ok 👌

  • @paulgardner3926
    @paulgardner3926 Месяц назад +3

    I’ve fitted 2 this week but I knew what was coming. I like them to be honest. Can’t go wrong for £650 inc vat

  • @phoneblaster
    @phoneblaster Месяц назад +1

    ...you have to remember that there can be flaws in a brand new boiler. Dont forget that in the factory where they are put together or assembled parts maybe faulty but they will still put it on. Like for example a diaphragm might have a very thin 'needle' borehole. . Depending on the material it may need replacing immediately or gradually get worse then becomes apparent. I n a Microsoft software they forgot to put the 'Print' command. I am referring to the bracket being in the way of the rubber flue ring seal after it has been cemented . I am thinking either the bracket needs to be cut away after it's positioning has been set so the ring will be flush with the wall or the ring goes behind the bracket. Any criticism welcome. .

  • @benfrost8697
    @benfrost8697 Месяц назад +3

    Vaillant said for years not to use any silicone lube on the flue seal because it damaged them. Would be interesting to know if they have changed what they are made from .The seals reacted and rippled to silicone. Have seen so many flues rotten through at an early age 👍

    • @robertmailer4978
      @robertmailer4978 Месяц назад +1

      Had so many vaillant seal fail it bonkers, even when they put in dry, the condensation acid make them distort and leak, have spoke to tec, his reply was we don’t make the flue🤣🤣🤣unbelievable

  • @peterreid4567
    @peterreid4567 Месяц назад +2

    Ferolli make the worst boilers. We fitted 800. On contracts. Had to take the whole lot out. Total crap

  • @paulsmith2931
    @paulsmith2931 Месяц назад +1

    I fitted a lot of Glowworm and Vaillants, only fitted that boiler once and it put me off fitting another one, only a five year warranty on it as well, prefer the Worcester 1000 as a budget boiler to be honest.

  • @tonyadams380
    @tonyadams380 Месяц назад

    Thanks Derek. Know to give this one a miss!

  • @MagicDoughnut
    @MagicDoughnut Месяц назад +1

    I noticed you didnt trust just 2 bolts holding the boiler up either.

  • @YoutubeHero666
    @YoutubeHero666 Месяц назад

    the condensate and the PRV into the 40mm pipe are glow worm happy with that setup? As I know when I fit Ideals ect they recommend the use of a tundish for example the Hotun when combined condensate and prv into pp pipe. I have seen a few like this recently. I know the glow worm manual does say "The components must be set up in such a way that
    you can see the water flowing out."

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад +1

      It’s a fault put into the pipe work so trainees can find it on inspection you are totally correct it needs a tundish or the hotun when installed this way.

    • @YoutubeHero666
      @YoutubeHero666 Месяц назад

      @@tomkatgastraining Hi, thanks for the reply.

  • @courtneywhittle6534
    @courtneywhittle6534 Месяц назад

    Hi I’m looking for some advice
    I’m working on static caravans,their is a natural gas meter that is NOT connected to the caravan it is on a stand about a foot away from the caravan,I have been looking and looking and cannot find the legislation that states on a static caravan if the meter is not connected to the caravan it has to be on a flexi hose and not hard piped? Could you please shed some light?

  • @talesfromthepubshed
    @talesfromthepubshed Месяц назад

    Definitely give this one a miss, Alpha boilers the same with the different pipe work set up underneath, They also supply a cross over kit. Just a quick question, What does everyone use on dot & dab walls to seal the flue inside? I’ve used sand & cement but a year later when I go back to service it the sand & cement mix has usually come out 😳 I know some manufacturers like Ideal let you get away with just the internal seal so long as outside is done.

  • @plumbertime
    @plumbertime Месяц назад +1

    It’s all about ranges!
    They deliberately do this. Why make a £400 boiler as good as a £1000 boiler.

  • @peterreid4567
    @peterreid4567 Месяц назад

    Got to ask. The condense pipe can’t just sit in the black plastic pipe. I’ve been told in case the trap runs dry and products of combustion can leak into the room. Not me saying this Some. Mi say it.

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад +1

      Just remember this boiler was installed in a training centre with faults put into the install.

  • @mgbroadsterJ
    @mgbroadsterJ Месяц назад

    Fit Baxi or if the customer wants the best Viessmann .

  • @efrygasservices6169
    @efrygasservices6169 Месяц назад

    Just thread the collar on from the other end and it slips straight over the ridge 👍

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад

      Can’t do that when you have had to bricked up the outside and need to slide it over the terminal 😢

  • @markchristohperowen6806
    @markchristohperowen6806 22 дня назад

    shouldnt they take that cost on not the customer?

  • @dparker1443
    @dparker1443 Месяц назад +1

    Couldn’t believe they decided to change the return pipe for the mains…..thought it would be a nice easy straight swap!

  • @SuperWayneyb
    @SuperWayneyb Месяц назад

    🤘😎🤘

  • @mgbroadsterJ
    @mgbroadsterJ Месяц назад

    What's it like ,doing some work ?

    • @mgbroadsterJ
      @mgbroadsterJ Месяц назад

      why bother fitting those boilers ?

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад

      Not a clue haven’t done any for the last 10 years 🤫

  • @yensabi
    @yensabi Месяц назад

    I don’t think I’ll be fitting any of those Derek , it just looks... 💩
    Let’s see how it performs...!!

  • @carlfisher5195
    @carlfisher5195 Месяц назад +2

    What a load of crap...! cheap parts, poorly thought out design.... I'd love to make the designers and the accountants at Glow-work get out there and fit them...!! They'd soon scuttle off back to the office..!!

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад +2

      I was very surprised by the boiler when I first saw it at phex let’s see what it’s like to commission and repair in future videos

    • @carlfisher5195
      @carlfisher5195 Месяц назад +2

      Thing is Derek, they're shooting themselves in the foot.. if the boiler's a pain to fit, the installer won't recommend it to the customer..!! Very short sighted... and that picture of you in pain under boiler is enough to put me off.... 😂

  • @markchristohperowen6806
    @markchristohperowen6806 22 дня назад

    another reason not to install glowworm or vaillant if you can help it. installed top of the range vaillant not long ago not impressed. plus you get the anal engineers on warranty callouts always blaming installers. how hard can it be to design a good boiler?are zee germans still sad they lost and still screwing us over? from plastic parts failing to pressure sensors designed to catch dirt. thats on bosch too. plastic hydrolic blocks failing on boilers where theres zero mention on expantion in the MI.
    tomcat dont get me started on alpha i see your an accredited installer. why put an lcd screen on the pcb knowing they put a shitty transformer on the same board.

  • @barrybradfordlocksport
    @barrybradfordlocksport Месяц назад +1

    No worst is a the sharp ferrari quality well known piece of crap known as worcest######

  • @mgbroadsterJ
    @mgbroadsterJ Месяц назад

    I would refuse to fit that rubbish .

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад

      So if the customer asked you to fit it you wouldn’t 🤔