Baxi/potterton promax E133 fault

Поделиться
HTML-код
  • Опубликовано: 16 ноя 2022
  • Quick video on how I go about repairing boilers and how I listen to what’s going on

Комментарии • 37

  • @iqbalnuthoo1566
    @iqbalnuthoo1566 2 дня назад

    Thank you, good explanation

  • @user-iy8vq4mj7s
    @user-iy8vq4mj7s 4 месяца назад

    Thank you for being clear with explaining most just go on and don't get to the point ...but you are clear with helping us engineers .

    • @snapgas9832
      @snapgas9832  4 месяца назад

      Haha cheers, love to chat, what can I say 😂

  • @Carl-re6zb
    @Carl-re6zb Год назад +6

    Nice one brother...
    Carbonisation of the electrodes and rectification probes is very common.
    The state of the electrodes gives a good insight into if the burner mix is too high or too low..
    Burnt or melted probes can mean too high carbon ratio or heavy coating to little.
    Correct set up of the gas/air ratio very important to correct operation.

    • @snapgas9832
      @snapgas9832  Год назад +2

      Thanks for the info mate this is what comments sections are for

  • @JoseFigueroa-gv4db
    @JoseFigueroa-gv4db 7 месяцев назад +1

    Thanks for uploading! I had same exact symptoms. Allowed me to narrow down cause. I cleaned the probe but issue persisted. Ended up being the contacts on the other end of the cable needed cleaned. Contacts calcified from a prior leak.

  • @dimitriskatsiaounis1290
    @dimitriskatsiaounis1290 Год назад +2

    Well done mate Good presentation and valuable tip!

  • @macpatel7810
    @macpatel7810 Год назад +1

    Some good hints and tips there mate. Appreciate you sharing..

    • @snapgas9832
      @snapgas9832  Год назад

      No problem hope it helps

    • @rayc1503
      @rayc1503 Год назад

      Great stuff pal, I generaly use a file to clean spark and rectification electrodes. Works better then wire wool or sandpaper. 👍

  • @plumbingheatingandgas8545
    @plumbingheatingandgas8545 Год назад +1

    Great work mate keep it coming,

  • @craigmcgregor5463
    @craigmcgregor5463 8 месяцев назад +2

    Been missing your videos mate. Hopefully your back soon. Always seems to happen. Engineers go in a different direction or just stop filming.
    More importantly, hope everything's good with you 🎉

    • @snapgas9832
      @snapgas9832  8 месяцев назад +2

      Thanks mate, had lots of family issues to resolve
      Then got married and all sorts haha
      Cheers for the support craig

  • @garethmccarthy8228
    @garethmccarthy8228 Год назад +3

    I had E133 yesterday, it turned out to be a split condense pipe leaking onto the flame rectification plastic joint and cutting it out. It was the original grey flexible one, replaced to black hose.

    • @snapgas9832
      @snapgas9832  Год назад

      Yep that’s common on these too

    • @cheeky1187
      @cheeky1187 Год назад

      Litrally have the same leaking boiler and have not had heating or hot water since 5 15 on 16th Dec.. should be fixed oin next 24 hours but exactly same issue it's leaking and putting the pilot light out

  • @cynt1111
    @cynt1111 Год назад +1

    Cheers, going out to one of these tomorrow.

  • @mouradchallal6256
    @mouradchallal6256 2 месяца назад

    Thanks for video

  • @nickcannon5592
    @nickcannon5592 Год назад +2

    Nice one

  • @donpetkov73
    @donpetkov73 8 месяцев назад

    I have this E133 after installing a new PCB installed from a E168 caused by installing a new smart meter. Do you cover Romford?

    • @snapgas9832
      @snapgas9832  8 месяцев назад

      I’m really sorry I don’t anymore I’m a bit too far away,
      Sounds to me like the gas may not be getting to the boiler or needs to be purged
      Please call a local gas safe engineer to repair or rectify this
      Thanks for watching

  • @jorose8486
    @jorose8486 Год назад +2

    Had a strange one on a same type of baxi can’t always believe the code faulty rf room stat causing same code which doesn’t make any sense

    • @snapgas9832
      @snapgas9832  Год назад

      That’s unusual never would of thought that

  • @1966reilly
    @1966reilly 7 месяцев назад +1

    Guys got a eco compact 30 hot water runs fine but no heating.rads and water symbols shown but no flame when demanding heating.The red and green lights are flashing on receiver cant solve?i have turn the hot water dial 90 degrees twice it fires up with flame symbol then heats up then flame goes out do it a couple of times then i get flashing error 133 flame crossed out and an R top right above error number. i have blaming my receiver and thermostat no connecting does that narrow it down ?its getting cold. regards

    • @snapgas9832
      @snapgas9832  7 месяцев назад

      Please contact a gas safe engineer to solve this issue
      Thanks

  • @warishussain316
    @warishussain316 4 месяца назад +1

    How much full service of boiler if I contacted u how can do

    • @snapgas9832
      @snapgas9832  4 месяца назад

      £75 but depends on where you are mate

  • @lostinthoughtscalminsilenc8167
    @lostinthoughtscalminsilenc8167 4 месяца назад

    What if it don’t reset?

  • @1966reilly
    @1966reilly 7 месяцев назад +1

    Quoted 350+ for repair 133 error and cover ground worker mate came around and disconnected thermostat on wall works now overpriced over complicated 😂