    After installing these inductive switches, I could not make my machine to reference all axes home if I had the limit switch function enabled, and if I did enable the function, when a switch was triggered, then I could not back out of the triggered switch due to the machine not resetting. On this video I describe the problem and what I had to do to solve it.
    / @carlosmdominguez
  • ХоббиХобби

Комментарии • 28

  • @iiianydayiii
    @iiianydayiii 2 месяца назад +1

    This was helpful. I've been looking for a solution to my limit switch issue and saw configuring a debounce setting as a possible solution. No one explains exactly which debounce setting to enter though, as there are two. I entered your setting of 1000 and my cnc router now homes w/o issue. Thanks.

  • @doghouse4538
    @doghouse4538 Год назад +4

    Usually, on machinery (CNC, automated robots, etc.,) I would see what they would call a software limit switch and a hardware limit switch. In this case, you have a hardware limit switch type setup, which would be your Inductive Proximity Switch (which is referred to as limit switches in this video). But it doesn't appear to have a software limit switch, at least from what I can tell. Usually, the software limit switch would be like your primary stop, and your hardware limit switch would be almost your like emergency stop. Like just in case a servo motor lost its position, or the wrong values were input into the program. It would halt all functions, in an attempt to prevent further damage to the equipment or product. But you can also use the Hardware Limit switch as a homing/referencing switch, which is what you did here in this video. Not entirely sure what goal you have in mind for this setup, or what all you are planning on doing with it. But Cool as heck to see someone successfully troubleshooting an issue, as opposed to just working around it. Some of which is things I constantly have to deal with on a weekly basis, lol. Best of luck to you!

    • @CarlosMDominguez
      @CarlosMDominguez  Год назад +2

      Thank you very much for your observation, in effect I have soft limit switches activated on mach3 and the physical switches are mostly used for homing as you pointed up, you have to take in count that I'm just a hobby CNC er, and never worked on this things until a couple of year ago, nevertheless the more I learn about it, the less confident I feel.
      (you know: "dunning kruger"). Thanks again for your comment!

  • @mirceapuscasu3495
    @mirceapuscasu3495 2 года назад +2

    Thank you very much for this video, very good explanation and very helpful, I have to stay stuck with this problem about settings but now I have the solution thanks to you

    • @CarlosMDominguez
      @CarlosMDominguez  2 года назад

      You are welcome!
      I am so glad to hear it help.
      Greetings.

  • @mikem5226
    @mikem5226 10 месяцев назад +2

    Thank you, I was running into that problem as well

    • @CarlosMDominguez
      @CarlosMDominguez  10 месяцев назад

      Glad I could help. Thank you for watching.

  • @jaimevillada9150
    @jaimevillada9150 3 года назад +2

    Desde Colombia, mil gracias por enseñar y compartir.

  • @arjundas708
    @arjundas708 2 года назад +1

    Thank you sir, good information

  • @practicemakesbetter7132
    @practicemakesbetter7132 Год назад +1

    Great video, I will have to give it a try! That is a very nifty looking controller that you were using, did you make it or buy it?

    • @CarlosMDominguez
      @CarlosMDominguez  Год назад

      I bought it from Zilotech, but I'm not sure if they still on business. Thanks for the comment.

  • @glaudsonferreira9030
    @glaudsonferreira9030 4 месяца назад +1

    meu amigo eu estava com esse mesmo problema ate vc aparecer, muito obrigado pela ajuda um grande abraco

  • @kevlarlive
    @kevlarlive 2 месяца назад +1

    Thank you.

  • @carlosmariche
    @carlosmariche Год назад +1

    perfect!!!

  • @IH1940HAY
    @IH1940HAY Год назад

    Do you have a fix for pressing the button between pulses, there should be a setting that is applicable?

    • @CarlosMDominguez
      @CarlosMDominguez  Год назад

      That is the fix I think, unless I did not get your question.

    • @IH1940HAY
      @IH1940HAY Год назад +1

      @@CarlosMDominguez there should be something in the system that makes for a more positive approach rather than just getting lucky and hitting the button just a the right time.

    • @CarlosMDominguez
      @CarlosMDominguez  Год назад

      @@IH1940HAY Oh I got it. You know, I am a little rusty on all of this stuff, It is been more than a year since my last video. I hope I can get back into it as soon as I have a place to work in the near future. Sorry I can not answer your question satisfactorily. Thanks for the comment and stay tuned.

  • @alirazs1660
    @alirazs1660 3 месяца назад

    sir i have a problem that when i check on auto limit in limited think three they are running and mac show three pin number and when i do al home limited switch stop working machine What is the solution for limited switches crossing?

    • @CarlosMDominguez
      @CarlosMDominguez  3 месяца назад

      I’m not sure what the question is. Perhaps you could rephrase it so i could try to answer. thanks.

  • @user-dv7th2qr1m
    @user-dv7th2qr1m Год назад

    06:42 starting to explain about Debounce

    • @CarlosMDominguez
      @CarlosMDominguez  Год назад

      Yeah, may be I need to do it better in another video. Thanks for the comment.