Foundation/ Footing Mistakes on Site | Foundation Construction Mistakes |

Поделиться
HTML-код
  • Опубликовано: 13 янв 2025

Комментарии • 29

  • @tpee_arts1263
    @tpee_arts1263 3 года назад +15

    I think Development length should be place on bottom reinforcement, not on the top reinforcement of the footing.

  • @mehmoodhse
    @mehmoodhse 3 года назад +3

    You are giving useful information all the time. Good effort

  • @selvaganapathy5147
    @selvaganapathy5147 3 года назад +8

    You didn't mention that using bricks as cover it will corrode the rebars if the water level increases as brick has the tendency to absorb water and also at one column the bend has been in the opposite direction and first of all the marking should be done properly and the alignment should be checked throughly.

  • @pranotostb
    @pranotostb 2 года назад +1

    Good contrcsion

  • @kappuhangsing5278
    @kappuhangsing5278 Год назад

    This video is so useful, thanks a lot sir

  • @AhmadAhmad-nt7wr
    @AhmadAhmad-nt7wr 2 года назад

    Niice

  • @risukbha1189
    @risukbha1189 2 года назад +1

    What should be the sizes of columns for three storey building

  • @AhmadAhmad-nt7wr
    @AhmadAhmad-nt7wr 2 года назад

    👍👍

  • @santhoshyadav5830
    @santhoshyadav5830 2 года назад

    Duck legs should be at bottom of footing is it right?

  • @bluesky2143
    @bluesky2143 2 года назад

    How can fix in centre when we have boundary wall

  • @albertjatta476
    @albertjatta476 2 года назад

    Why the second footing piller in the video is not at the center

  • @iamphyize
    @iamphyize 3 года назад +1

    This mistake is commonly made, thanks for giving this idea

  • @nadirm594
    @nadirm594 3 года назад +2

    Horrific earthquake in 2005 (millions dead) but nothing learned, shoddy construction goes on

  • @RuheelKhan
    @RuheelKhan 3 года назад +1

    Thanks a lot, tomorrow i was going to execute same footing at site . That will definitely help.

  • @stevenkulumba4125
    @stevenkulumba4125 3 года назад

    Am watching. Stephen in Qatar

  • @jeffreyromero9169
    @jeffreyromero9169 Год назад

    Engineer: "Redo everyone"
    Contractor: "S#%t... there goes my profit"

  • @STREET_FOODY
    @STREET_FOODY 3 года назад

    Thanks a lot brother 🥰

  • @manojparida5556
    @manojparida5556 3 года назад +2

    This is 12mm not 16mm bar

  • @garymunoz6649
    @garymunoz6649 3 года назад +1

    Its not a mistake....its a common practice among contractors that want to profit more🤣🤣🤣 nice vid!

  • @naturalworldksa
    @naturalworldksa 2 года назад

    নতুন ছাদে পানি দেওয়ার পর কালো কালো দাগ ওঠে কারণ কি

  • @armyofficermanishsharma5039
    @armyofficermanishsharma5039 3 года назад +1

    valikum assalam sir

  • @rajasekars9782
    @rajasekars9782 3 года назад

    Lateral rod not 16mm

  • @pukeschannel6882
    @pukeschannel6882 2 года назад

    I gave up, I couldn't u nderstand much of what you said, and youtube was no help. Whatever you do, make sure you leave those water absorbing bricks in there so your bottom rebars can rust out. Have a nice day.

  • @PBS-nm1uu
    @PBS-nm1uu 2 года назад

    inches, meters , confusing , makes this video suck.

  • @bilaldigital7740
    @bilaldigital7740 2 года назад

    Ap apna number send karey mai call karta hu please