Auto Charging By Subcooling w/ The Testo 560i Scale and Smart Valve

Поделиться
HTML-код
  • Опубликовано: 2 окт 2024
  • The Testo 560i Scale and Smart Valve allows HVAC and refrigeration techs to manually charge or auto charge by sub-cooling, superheat or weight. In this video I experiment with the auto sub-cooling portion.
    The 560i scale and smart valve can be paired to a 557s or 550s manifold or Testo Smart app. If you're using an older manifold, ensure to perform an update using the Testo Smart app to add the "Refrigerant Filling" line to measurements section of the manifold. The smart valve can be opened to purge out refrigerant lines by by pressing the button 3 times quickly which is a nice feature.
    Check out the link for more info...
    www.testo.com/...
    Save 8% on your purchase at www.trutechtoo... with promo code knowitall
    Check out the HVAC Know It All app app.hvacknowitall.com
    www.hvacknowit...
    Visit HVAC Know It All on social media
    Facebook
    / hvacknowitall
    Instagram
    / hvacknowitall1
    #hvac #refrigerantchargingscale #refrigerantcharging

Комментарии • 50

  • @HVACKnowItAll
    @HVACKnowItAll  2 года назад +8

    The future of charging

    • @ethanhogan9089
      @ethanhogan9089 2 года назад

      All I see is another expensive piece of equipment to have to carry around, maintain and eventually replace. I genuinely don’t see what this accomplishes other than metering refrigerant for you, which you can do with a hose and ball valve manually for Im sure a fraction of the price. I get the gauges, love mine. I love scales. Those tools accomplish something. This I’m not so sure of but I also like to be hands on. I get it, not a lot of technicians
      Know how to charge a system properly or even know what subcool or superheat are so probably extremely useful for the unskilled so your probably right with it being the future lol.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 года назад +4

    I just got mine yesterday

  • @HVACRSurvival
    @HVACRSurvival 2 года назад +2

    I had problems updating the manifold, it would fail at 10-30% with Android and IOS. I tried every trick Testo had. My new manifold will be here hopefully in a day or two🤞. I'm looking forward to playing with this. Good video explanation of how it works 👍👍

  • @keepthinking2666
    @keepthinking2666 Год назад +2

    Also are you charging 410A in the gas side

  • @airmanhvacr
    @airmanhvacr Год назад +1

    Neat, but just not practical. By time I set it all up, input all data, do updates, connection issues, adds another hour+ to job costs. Nice video tho...

    • @SuperComfee
      @SuperComfee Год назад

      ur just an airhead, takes me less than 10 mins.

  • @borabora5238
    @borabora5238 11 дней назад

    On superheat mode, you can only use it on split system with fixed valve. Does the same apply to charging through target superheat or subcooling? Did you enter temp manually or used the 605i? It seems they dont let you use the 115i for this mode, so you need to buy the 605i 🤡

  • @jonathanl2822
    @jonathanl2822 2 года назад +3

    Is that pure 410A? Never seen a tank like that .

  • @scottk0623
    @scottk0623 2 года назад +2

    I’m beginning to believe Testo owns Duracell 🤣🤣. I understand the accuracy of this but it it taking away the purpose for tech to think about what is actually taking place in the system.

    • @HVACKnowItAll
      @HVACKnowItAll  2 года назад

      Not exactly, thinking is all in the set up. Then it still needs to be monitired.

    • @willllo
      @willllo Год назад +3

      To be fair mate when it comes down to it all the temps/pressures are just numbers if the tech hasn't got a clue in the first place. A lot of engineers I've worked with don't know how to charge to subcooling. They would decant and recharge to the unit spec weight and add any extra needed by estimating the pipe run if it wasn't printed on the side of the outdoor. I've got these gauges all they do for me is makes reading the pressures and temps a lot faster/more efficient. I'll spend money on anything that saves times. Not like I'm going to be doing a different job in 10 years 😂

    • @AmbiguousAndrew
      @AmbiguousAndrew Год назад

      Well you do still have to know how too set it up, digital manifolds just do the pressure minus line temp for you lol

    • @5822huron
      @5822huron Год назад

      Not at all. It actually helps him understand.

  • @sowhatimliving
    @sowhatimliving 2 года назад +2

    🥵🥵🥵whelp finally found a reason to switch from digital probes to digital manifold 🤣🤣🤣🤣I been holding out but this 🔥

  • @mantis_atlantis
    @mantis_atlantis 9 месяцев назад

    What's the difference between 557s and 570s? Will it work with 570s?

  • @Tbaria
    @Tbaria 2 года назад +3

    I hope everyone uses these

  • @Shiftytrucker
    @Shiftytrucker 2 года назад +2

    Hi Gary! The saturation temp you mentioned, is that personal target more from experience or is there a metric to target that? I’ve noticed around a 20° to 25° difference from indoor temp to what sat temp on suction is and have made the correlation, just wanted to know if it’s based on anything scientific or just plain happenstance.

    • @HVACKnowItAll
      @HVACKnowItAll  2 года назад +1

      40 SST is a nice place to be for AC when the room is close to or at setpoint. In my experience the TD you're talking about is closer to 30⁰F to 35⁰F

    • @Shiftytrucker
      @Shiftytrucker 2 года назад

      Ok, I’m going to pay closer attention to that going forward. I appreciate the response!

  • @5822huron
    @5822huron Год назад +1

    I never saw you reach 10F SC.. You said you did. Did you skip a little video?

    • @HVACKnowItAll
      @HVACKnowItAll  Год назад

      It reached 10 then dropped back down to 8. I wasn't filming the whole time.

  • @donaldbakerakathedonaldaka5261
    @donaldbakerakathedonaldaka5261 2 года назад +2

    Can it be used with smart probes and a charging tee?

  • @anthonyshaw15
    @anthonyshaw15 2 года назад +4

    Perfect timing for this video!! I just got the 550s and the 560i kit and was having issues. Ended up running out of time on the call and had to charge with my field piece scale. Can’t wait till tomorrow to work out all the bugs. Probably just needed the update.

  • @alcapone3481
    @alcapone3481 7 месяцев назад

    Yor subcool said 5 tho?

  • @georgejorgensen498
    @georgejorgensen498 Год назад

    does it work with the older 557s

  • @nathanpatterson9674
    @nathanpatterson9674 Год назад +1

    Do you need the scale or are you able to use just the smart valve and the manifold?

    • @HVACKnowItAll
      @HVACKnowItAll  Год назад +1

      I suppose you could just use those. Without th scale though, how would you know the weight?

    • @RickyGee-ut8hk
      @RickyGee-ut8hk 3 месяца назад

      by weighing the tank before and after

  • @AnishKumar-dx4bz
    @AnishKumar-dx4bz Год назад

    Hi guys pls guide to connect testo weight scale with valve to mobile device via blue tooth

  • @jx5hficus176
    @jx5hficus176 Год назад

    Is this only comparable with testo products , I use mostly field piece

  • @zachgibson2285
    @zachgibson2285 2 года назад +1

    Why charging with bottle upright?

    • @HVACKnowItAll
      @HVACKnowItAll  2 года назад +1

      It has a liquid valve on it with a dip tube.

  • @nbctcp3450
    @nbctcp3450 4 месяца назад

    can u change to Celsius and R32 refrigerant

  • @aaronphillips7671
    @aaronphillips7671 Год назад

    What is the charging rate, if I have to add a lb will it take an hour

  • @afbigfish1
    @afbigfish1 9 месяцев назад

    I wish Fieldpiece offered this...

  • @therealfreekshow
    @therealfreekshow Год назад

    How long did it take

  • @thebeardedstork432
    @thebeardedstork432 2 года назад

    Oh Brudder!!! I long for the good ol' days before all this digital crappolla! LOL

    • @David-lf2ne
      @David-lf2ne 2 года назад

      Those who can use a sling psychrometer and pocket thermometer with slide charts and analog 2 valve will be few.

    • @thebeardedstork432
      @thebeardedstork432 2 года назад

      @@David-lf2ne sigh…..

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 года назад

    👍

  • @gaylormatthewson9884
    @gaylormatthewson9884 2 года назад

    😠 【promosm】