Fire Alarm Installation Training - Design Tutorial Part 1/3

Поделиться
HTML-код
  • Опубликовано: 21 авг 2024

Комментарии • 119

  • @Synthminator
    @Synthminator 3 года назад +3

    Thanks for the presentation Eugine, just started in this field, very helpful

  • @roderickbalolong6795
    @roderickbalolong6795 3 года назад +2

    The best FDAS video tutorial.

  • @KatoriaLuke
    @KatoriaLuke 3 месяца назад

    Thank you Eugene you have gone really thorough with your presentation. I've told all my dealers to go through your video also.

  • @andybenavides8066
    @andybenavides8066 3 года назад +1

    Sir thank you po para sa very informative na video nyo. Laking tulong po nito sakin lalot beginner palang ako sa field na to. Papanuorin ko lahat ng videos nyo sir para mas marami pa kong matutunan. Thank you ulit sir. Stay safe and Godbless po. 😁

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Thank you Andy for the support and appreciation. Basta may concern ka regarding sa mga videos, please feel free to ask. Stay safe din and God bless!

  • @ianrichards1968
    @ianrichards1968 4 года назад +3

    Excellent Eugene, you could have warned about the sound on the last slide, I nearly jumped out of my skin😱

  • @imBhootiyakahani
    @imBhootiyakahani Год назад +1

    nice tutorial video plz make more videos on fire alarm system🙏🙏

  • @gilbertotorres8657
    @gilbertotorres8657 2 года назад +1

    I starting my career as a drafter. I also would like to move towards being a fire alarm designer. Thanks for the videos

  • @yakikadafi6189
    @yakikadafi6189 3 года назад +1

    Oh hello sir Eugene thanks a lot for this corse it helped me a lot I’m a electronics and communications engineer too plus I’m industrial automation systems engineer and now I have to learn fire safety systems

  • @mohammedobeid7643
    @mohammedobeid7643 3 года назад +1

    Really enjoyed your intro to fire alarm systems

  • @tahseenmubarak4118
    @tahseenmubarak4118 3 года назад +2

    Great work Eugene. Very informative. Please make a video on Modbus TCP/IP communication between panels, BMS, SCADA system, PLC, and its operation.

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Hi! Thanks for watching. Sure, we'll consider your request once we finish other videos.

  • @xavierthankaraj1381
    @xavierthankaraj1381 2 года назад +1

    Excellent Explanation Sir. thank you so much.

  • @ammaraloush6313
    @ammaraloush6313 5 дней назад

    Very nice

  • @chibuabishake9666
    @chibuabishake9666 3 года назад +1

    Sooperb bro . Your really a pro . Keep up the good work and thanks for sharing your knowledge

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      You're welcome bro. Glad you liked the videos. There's more to upload soon.

  • @asiibrahimasi4
    @asiibrahimasi4 4 года назад +1

    Outstanding presentation eugene.
    It really helps for beginners like me, keep doing

  • @mamusavvirmohd9133
    @mamusavvirmohd9133 Год назад

    Very Informative. Thanks Eugine

  • @jayakrishnans1030
    @jayakrishnans1030 4 года назад +1

    Nice Presentation Eugine .
    Keep going

    • @AllaboutFireProtection
      @AllaboutFireProtection  4 года назад +1

      Hi bro...thank you...Yes i will add some other more trainings...miss the old times...

  • @anandsooriyan7749
    @anandsooriyan7749 4 года назад

    Good presentation for all beginners.
    Super bro.
    Keep continue.

  • @amrtome5657
    @amrtome5657 11 месяцев назад

    Thank you.

  • @fliqur6516
    @fliqur6516 7 месяцев назад

    Can we have an explaination/route plan of how you went from a draughtsman to lead fire alarm system designer in 2 years? I just started 3-4 months ago, have extensive CAD knowledge and Revit. Also Rhino. I'm quite good with dialux/relux. Is there any training you recommend to advance? I've done a couple of courses, have another booked soon. These taunt me european and british standards for light, lighting design and fire detection and alarm system design in non-domestic buildings.
    I look forward to your reply :)

  • @Explore_FnT
    @Explore_FnT 3 года назад

    Awesome session...

  • @linuxguy3279
    @linuxguy3279 3 года назад +1

    interesting!

  • @xyholland
    @xyholland 2 года назад

    Hi, you should have warned about sound level before 30:18

    • @AllaboutFireProtection
      @AllaboutFireProtection  2 года назад

      Yes, I think so. Only if I could edit the video that was uploaded long time. Thanks for watching.

  • @lolpog600
    @lolpog600 4 года назад

    Loved the video

  • @amirhossein6257
    @amirhossein6257 Год назад

    Thank you sir this is so informative. Do you have any pdf for FDAS design and guidelines. Thank you!

  • @runbou3485
    @runbou3485 Год назад

    Thankអរគុណ👏

  • @dingcolarte6131
    @dingcolarte6131 3 года назад +1

    Sir...can I have a request again a favor? The existing building (3-story) needs to install an elevator, the proponent wants the elevator to be connected to the existing FACP conventional system, recall elevator to the primary floor and recall elevator to the alternate floor (if a fire occurs). What are the additional devices to be connected to the existing FACP in order to function the elevator smoothly?

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад +1

      Make sure when you interface elevator to FDAS, there is a smoke detector in the elevator lobby within 6.4 mtrs from centerline of elevator or if you have sprinkler inside the elevator shaft, then you must have both smoke & heat detector inside shaft installed for elevator recall & elevator shunt.

    • @dingcolarte6131
      @dingcolarte6131 3 года назад

      @@AllaboutFireProtection Thank you very much sir....

  • @roderickbalolong6795
    @roderickbalolong6795 3 года назад +1

    Sir, I have a question , is the speaker audible notification appliance is built in power amplifiers? or it's required external amplifier? Thank you in advance sir.

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад +1

      Hello thank you for watching. No built in. The speaker will be connected from the amplifier and the strobe light is connected from the fire alarm NAC circuit if the speaker is with visual notification.

  • @nelsoncapalad3387
    @nelsoncapalad3387 3 года назад

    very good bro

  • @tadeseoyebolanora1872
    @tadeseoyebolanora1872 3 года назад +1

    Nice work sir, pls i need pdf for fire alarm system design and guidelines.

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Thank you. Please give me your email id and i'll send the link.

    • @nihalnazir3775
      @nihalnazir3775 3 года назад

      daniyalnazir1993@gmail.com
      Please send me also the tutorial in pdf

  • @CHATLAMBERT
    @CHATLAMBERT 4 года назад

    Great 👍

  • @user-ke4fi7sp9l
    @user-ke4fi7sp9l Год назад

    sir baka may alam po kayo na pwedeng pag trainingan kung pano mag install ng FACP and mag commissioning or program nung system sir....salamat

  • @Travelling_Duniya
    @Travelling_Duniya 2 года назад +1

    Thanks for the presentation. Can I get the presentation file?

    • @AllaboutFireProtection
      @AllaboutFireProtection  2 года назад

      Hi, sure you can download it from here. Thank you for the support. we.tl/t-ZkVNxRCNpx

  • @Dr-Shlomo-Cohen
    @Dr-Shlomo-Cohen 9 месяцев назад +1

    Hi, I'm new to this. Looking for a career. How do I make money with this? What's a good certificate to get in this field? Any recommendations would be highly appreciated.

    • @AllaboutFireProtection
      @AllaboutFireProtection  9 месяцев назад +1

      Hello, it really depends on what your state or local code you're in. Some countries require local certificates to be certified as a fire alarm designer and some require that you get your certificate from the manufacturer of what brand you use in your design. But if you're looking for a certificate from a recognized organization like NFPA to start with your career in this field, then you can check the nfpa website and there are a lot of available seminars you can attend there like nfpa 72 for you to start working in fire alarm industry.

    • @michaelschwing
      @michaelschwing 3 месяца назад

      Engineering degree

  • @nelsoncapalad3387
    @nelsoncapalad3387 4 года назад

    nice bro thanks

  • @happydata3332
    @happydata3332 4 года назад

    Ikaw pala ito eugene ha...nice video eugene

    • @AllaboutFireProtection
      @AllaboutFireProtection  4 года назад

      Thank you! Pwede malaman kung sino sila 😀

    • @happydata3332
      @happydata3332 4 года назад

      @@AllaboutFireProtection Engr.Ono nakasama mo sa NAFFCO project department...

    • @AllaboutFireProtection
      @AllaboutFireProtection  4 года назад +1

      @@happydata3332 Ah ikaw pala yan idol. Salamat ahaha. Stay safe.

  • @cebusparkelectrical646
    @cebusparkelectrical646 2 года назад +1

    Good day Sir, can I asked copy for your presentation. Thank you

  • @pushpakpatel91
    @pushpakpatel91 3 года назад

    Hello, It's a really very good presentation. Can you please share with me this presentation. Thank you.

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Hello, here is the link for your reference. Thank you for your support. we.tl/t-OoFNBosUtR

    • @AbdulMalik-il7bp
      @AbdulMalik-il7bp 3 года назад

      @@AllaboutFireProtection could you send again pls? it is expired. Mega or gdrive

  • @richardbutiong8762
    @richardbutiong8762 3 года назад +1

    Very informative sir and well explained,. Any link sir for pdf files for guidelines in designing fdas.thanks and more power.

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Please tell me your email so i can send you the pdf. I appreciate your feedback. Thank you.

    • @richardbutiong8762
      @richardbutiong8762 3 года назад +1

      @@AllaboutFireProtection butiongrichard@yahoo.com thank you for your generosity, someone already sent me a copy from whom who also ask for the copy of your slides. Godbless!

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад +1

      @@richardbutiong8762 You are welcome Richard. I guess I don't need to resend then. Just feel free to ask if there something you need as long as i can help.

    • @richardbutiong8762
      @richardbutiong8762 3 года назад +1

      @@AllaboutFireProtection thank you sir, actually i have few more questions specialty about zoning, how to determine the number of detectors in one zone? Or how many detectors should i conect?thank you.

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      @@richardbutiong8762 We normally assign separate zone per floor otherwise if there is a fire or smoke compartment as fire division between areas to allow relocation of occupants to other zone as part of fire evacuation strategy then we can have more than 1 zone per floor. The quantity of your detector will depend on the number of device of your FACP can handle as per manufacturer's recommendation. If your system is conventional fire alarm system then it will depend on the capacity per zone, if it's addressable, then depends on device per loop.

  • @trinathdas1992
    @trinathdas1992 2 года назад +1

    I want to become a FA designer with certificate.. Please advise

    • @AllaboutFireProtection
      @AllaboutFireProtection  2 года назад

      Hi, if you are working in some country which requires NICET certification, then you can try to get this certification. Otherwise, you can try CFPS exam as most fire protection engineer do.

  • @bmg7862
    @bmg7862 3 года назад

    That's amazing...Can you Please send me the slides?

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Thank you for your support to our channel. Please check this link for your request. we.tl/t-C9CBzT4HqH

  • @halilack4174
    @halilack4174 2 года назад +1

    Hello, Could I take the pdf of this course?

  • @abkhaliltv7194
    @abkhaliltv7194 3 года назад +1

    Hy I am fire alarm technician how I com 🇺🇸

  • @nihalnazir3775
    @nihalnazir3775 3 года назад

    Hi, i work in kuwait. I want to gain practical experience by working on a project. Can you help me out

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Hi. Thank you for your support to our channel. How can I help you with your project? Here's my email so we can discuss about it eugenebaltazar.81@gmail.com

  • @skbdfireprotectionservice7829
    @skbdfireprotectionservice7829 3 года назад +1

    Hi. Sir.? How are you

  • @apc2729
    @apc2729 2 года назад

    Is Qatar standard same as this?

    • @AllaboutFireProtection
      @AllaboutFireProtection  Год назад

      Qatar is also following NFPA standard for the design and installation. While the requirement can be found from QCDD regulations.

  • @thesecurityhawk
    @thesecurityhawk 3 года назад

    will this help anyone pass a state exam for a license?

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад

      Hi. I don't advise anyone to use this as reference for exam. I'm just sharing information that could help to easily understand steps in designing of fire alarm from the requirements to standards.

  • @kasunoyofficial503
    @kasunoyofficial503 3 года назад

    Dikit na po dalawa idol Sana madalaw mo rin munting bahay ko

  • @talktoomuch6703
    @talktoomuch6703 4 года назад

    Addressable po ba sir ung example mo sa last part ng tutorial?

    • @AllaboutFireProtection
      @AllaboutFireProtection  4 года назад

      Yes sir, yung VESDA laser focus natin kung mapapansin mo nakakabit din cya sa loop pero in real wirings meron yan monitor module for trouble & alarm supervision. Hindi n lng natin cya ipinakita in detail s presentation.

    • @talktoomuch6703
      @talktoomuch6703 4 года назад

      @@AllaboutFireProtection paano sir ikabit ung tamper switch at flow switch sa FACP? dadaan pa ba yan muna sa monitor module tsaka nkaconnect sa loop? Pwede rin po bah ung sounder mo nasa iisang loop lng ng detectors mo without module?

    • @AllaboutFireProtection
      @AllaboutFireProtection  4 года назад

      @@talktoomuch6703 Yes sir, yung tamper at flow switch natin yan either may tagisa yan na monitor module or kung may dual module pede din yun na gamitin for both. Yung sounder natin pwede lng cya ikabit within same loop kapag yung FACP supported yung powered loop at ganun din yung audible mo kung addressable type cya at listed sa FACP mismo.

    • @talktoomuch6703
      @talktoomuch6703 4 года назад

      @@AllaboutFireProtection anu ibig sabihin sir na supported ung powered loop?meaning dapat specific na ung FACP na bibilhin mo ay may feature na ganyan sir? tsaka sir ilang wire po ba mag connect sa isang loop sa isang addressable type?2 wire lng po ba yan?at anung type of wire po na gagamitin? nagdedesign kasi ako ngaun tapos first time ko mgdesign kaya mejo nalilito pa po ako..

    • @AllaboutFireProtection
      @AllaboutFireProtection  4 года назад

      @@talktoomuch6703 yes, meron available sa market na addressable system na supported ang powered loop like honeywell. Kaya pag nagdesign ka make sure na iconsider mo yung limit ng manufacturer pag powered loop gamit. Kasi pag powered loop mas unti n lng yung pwede mo gamitin na devices sa loop at ilan lng na notification devices pwede mo gamitin. Meaning pwede dumami ang loop na gamitin mo dahil sa limit ng notification devices na ggamitin mo. Imibis na 1 loop ong halimbawa need mo naging 2 loops pa. So, make sure pag addressable system na supported ang powered loop, iconsider mo yung limit ni manufacturer like kung honeywell yung reference mo , sundin mo. Iba iba din capacity ng loop for every manufacturer pagdating sa facp kaya pwede ka ng magrefer sa kung ano manufacturer na gusto pag nagdesign ka or kung sa contractor ka follow mo kung ano specs ng facp na offer nyo. Pag sa consultancy ka namn, ikaw magdecide ano manufacturer ka magrefer na magmeet ng project specs mo.

  • @kalanamadusara4097
    @kalanamadusara4097 2 года назад

    my poor ears

  • @eunicesanao7616
    @eunicesanao7616 3 года назад +1

    Thank you sir this is so informative. Do you have any pdf for FDAS design and guidelines. Thank you!

    • @AllaboutFireProtection
      @AllaboutFireProtection  3 года назад +1

      Hello, Thanks for watching. You can download the file here : we.tl/t-PW20OWX4gE

    • @muhammedhussain6063
      @muhammedhussain6063 3 года назад +1

      Please email your presentations to iqbalsama@msn.com

    • @christianjerroque1716
      @christianjerroque1716 3 года назад +1

      @@AllaboutFireProtection pwede po ulit mahingi link expired na po kasi

    • @shravanskulur7060
      @shravanskulur7060 2 года назад

      Hi sir
      The link is expired....cud plss reshare the link.