Air Conditioner Not Cooling House | आयल चोकिंग बाहर कैसे निकाले सिस्टम से
HTML-код
- Опубликовано: 16 май 2022
- Split Ac Gas complete Suction Line cool But Room Inside Not Cooling
Split Ac Not Cooling | आयल चोकिंग बाहर कैसे निकाले सिस्टम से
#Split_Ac_Not_Cooling - Наука
Sir AP India me hote to main ap se kuchu sikhi le ta but ap dur hote huavi sab knowledge de rahi hai thankyou sir
Bhetareen bhai meri problem solve hogai meine ye khud hi krliyaa thank you soo much
God bless you bhagi very good 👍 information
Thnks u bde bhai😊
Best video friends
Thanks
Bhut acha laga bhai
keep it up sir
HAM APP KA SATH HAI SIR
technician ka liya bhoot zaroori hai ya
information
❤ Nice video sir....
Good information.
Good work sir
Thanku sir
Thank you sir for everything
Mr Amresh u r really great
Thanks bro
Thank you sir
Thank you
Thanks Bhai jee 55 es60 night ko rakh ne ser22 sahi chalega...
Very good video excellent boss thanks 👍🤠
Very Nice
Vary vary nice
Haan bhai apke jaisa koi h jo apne hi moo se apna tarif krta ho
good Sir
Great
HYUNDAI AC ka outdoor ka full wring ka vedio banaiye sir
सुपर sir
Thanks
Nice video sir par sir oil nikla hai isse koi compressor par dikat nahi aye gi na
Very good sir
Thanks brother
Good
Nice good
Vai Maine Naya ac liya 1.5 ton carrier ka magar wo outdoor unit zyada garam hawa Nehi de Raha hai,aur room utna thanda v Nehi kara Raha hai, jabki Mera ek saal purana ac 1.2 ton ka use zyada garam hawa phenk Raha hai aur acha thanda kar Raha hai, please suggest
Same issue haen mere sath bhi Haier ka dc inverter a.c hai
Chok nhi ho raha tha sir gass overfill kar di isliye compressor kaam nhi kar raha tha dikkat oil ki nhi hai overcharged gas ki hai apne oil vest kiya compressor ka
Bilkul sahi
Ha yaar yahi hua hoga sahi
😂😂😂😂😂
best teacher
Thanks
Sir g
Outdoor ka heating temprechar kitna ana chahiye
Outdoor fan ka
Good working
Thanks
Very important information
Thankyou sir
Welcome
Vai vot maja aaya
Thanks
Plz solution btaye sir
Aap ka se hai sir nice video
Very nice
Thanks
Dost mere pass gree inverter 410a ha. New lagwaya ta. Best coling te 1 year byd ab aaj coling nhe kar raha ha. Indoor outer be saaf Karwa deya hai
Aluminium coil flushing possible sir
You right boss
Thanks
inverter ac 2.5 amp leke chal rha h gas run preser hai 120
Thank you sir
But oil Kam hogya
Ha brother
Bhai tum hi to ho ek hum log ka liye
Very halp full video
Sir R32 ka section pressure 120/150 aur standing pressure 250/260 rheta plz reply
Bhai r 32 ka running preshar 60 kab hota hai
Ac off karke gas, nikalo tab oil aur gas liquid Balenceing rahega
Bhai apka number dijiye request hai
Split AC me R22 गॅस चार्ज किया, बॅक प्रेशर 65 है, सक्शन pipe मे नमि है, लेकीन cooling coil मे नमी नंही आ रही है, cooling कम है, outlet pipe मे पानी भी नहीं आ रहा है. इस्का solution bataiye.pls
Mere ac ka ptla wala pipe thandha hota h but mota wala nhi aur AC cooling nhi kr rha h to kya problem h
Maibhi kiya hu aisa falt
Is ke Mony charges kitne lene chaiye ji
Sir ji Naya Oil nahin dalna hota hai kya purana wast ho jaaye toh
Oil to gas ke saath Compressor se nikla isse chock kese khul sakta
Bhai dono pipe pani aa raha hai fir bhi chilnes kam hai
Kaha rahte hai riyad me, mai apse bat kar chuka hu, mai bhi Kushinagar se hu
Kya karu me kuch batao
Indoor and outdoor chal rah hy cooling bhi nhi kar rah tha jb apne jisa kah use Kiya fhir bhi kam nhi kar rah hy sir
Sir agar aise ac ka gas pura nikal de to etna sara oil bi nikal jaye ga tab bina oil ka compresser bar bar garam hokar trip nahi kare ga kya
Lins ki safai tyra bap kary ga. 😂
Bhai mai ek sawal kiya tha Facebook pe but reply nhi diye ho
Bhai window ac 5saal nahi chalne se kharap ho jata hai kaya?
Please reply me soon as possible
Amres bhai ak video sabhi refrigrant per banaye ki kaunsa kitna bhara jayega
Ok
Sir phir to cumpressor ka oil bhi kam ho gaya hoga kafi kyuki video me oil bohot barbad ho gaya hai or aap to jante hi ho ki compressor me oil kitna rahta hai to sir in future time hamara usi cumpressor me oil kami ki vajah se bhi problem ho sakti hai haina
Agar jyada temperature ho usme ham R32 ya R410 gas charge kre to risk hoga ki nhi ya bas head pressure badh jayega reply jarur karna bhai log jisko pta hoga
Ac me gas hai pur colleng nahi kar raha h
Sir g gas bhi full hay Amper bhi theek hain sab kch sai hay compressor 5 sec bad trip ho raha hay plz is problem ka btayan
Bhai wire check kro or capacitor fan motor nhi to system ma blocking choking hai
2 ton k split ac hai pressure Kam Jada hu ta hai ky problem hu sakta hai bat sakte hai aap
Please reply do
Bhai mujhe aapka nvr chahiye
Pump down psi 75 iss ko caplery change ker kay fix ker lo bahi
Hmm
Poora gas nikalneke baadh acchase flush bi karneka uske baadh vaccum
Excellent
Bhai same ye hi problem mere sath bhi aayi hai kal R 410 gas thi inverter AC tha gas nikal ke mene fir se gas dali vacuum bhi Kiya ache se tab bhi wo thik se cooling nhi kr rha hai
Hii bro
Bhai same issue mere sath bhi mene bhi aise hi Kiya fir bhi cooling nahi kya kare
Sir app hame kaam dila sakte hai saudi me
Hm dilwa denge hamre bahut janne wale hain
Kiya app Golf me kaam karte ho ....
Mai bhi AC Technician hu ..Golf jana chahata hu .... Process video banaiye sir ji Golf jane ka
Ok
Gas nikal raha hai ki oil nikal raha hai
Bro yar esy hi mery pas ho raha hai dc invertar hai daikin ka ac wo colling ni kar raha us ko vacuum kar k do dafa gas bari hai magar us ka haid pareshar bhara jata hai 170 tak chala jata hai or amper 2:50 leta phir kafi der bad is ka head pressure kam ho jata hai 140 ya 130 pe aa jata hai or amper is k phir bar jaty hai 4 ya 4:50 pe chaly jaty hai magar colling phir koi khas ni karta ye sir main to bara pareshan huwa para hun ye 1ton la ac hai or ye falad 3 ki ac main hai yaha par 😥😥😥
Bhai mene bhi daikin ka split ac liya tha 1.5 ton ka 2021 m.... 1 saal bahut badhiya chala...pr ab saala mechanic bula bula kr thak gya hu..koi kahta h gas km h..koi kahta h capilary filter chang honge ac chok ho gya h...kabhi garm kabhi halki thandi dwa de deta h ac samjh n aa rha..ab june chal rha h bahut garmi h or m ac hi theek krwata ghum rha hu...
Standing pressure 160psi hai lekin running me 40psi dikhata hai or cooling nahi ho rahi hai to uska filter or capillary badalna padega ya flushing karne se ho jayega ga sir
Gas Kam hai, standing se Matlab Nahi hai , running ko menten kariye
oil kyu char jata h coil me
Jab outdoor upr ho aur indoor niche jab aesa hota hai zyada isiliye kehte hai u trap dena chaiye
Bai mera b same he
Bhai Mera ac bar bar baans hojata h fs 25 dikata h indoor mn kia waja j
Ac kon sa hai
ऑयल नही डालना होगा सर
Sir R22 ki Tarah R32 or R410 bhi top-up kar sakate hain.
Ha
@@AMRESH11TECH lekin sir R32 ma or 410 ma 2 traah ki gas hoti hai hme kaise malum hoga ky konsi gas leak hoi hai
mere hisab se only 22 and 410 me , stills it would be better to remove all the gas and refill new can
410 top up mat karna bhai mere hisaab se kyunki wo 2 gaso ki misrad hoti hai compresser phatne ka dar hota hai
@@Najeem__khan yes bhai u are right , i checked 32 pure hoti hai and 410 mixed
You tube par bahot video deakhe hai par aap ke videos deakh kar kuch samaj aa rahai
Thanks
Amresh bhai ap aa gaye kya saudi fir se
Hi ha brother
100ki stating lga do tark sirf pumping khul jayegi
🤣🤣👌
vaiya apka nambr melega
😅
Hi sir kuish amdid
Kush amdid
Hello sir
Hi
Sir is situation mein ampere increase hoti hai ya decrease?
Jab Choke hota hai Hain to Ampier increase Hoti hai , lekin jab Choking khatm hota hai , discrease Hoti hai
Agar running me 40psi dikhata hai to kya kare
Gas Kam hai
sir ek ac hai saprit us ka compresor trip ho raha hai 20 second ke baad capostor bhi change kiya lekin fir bhi nahi chal raha heat ho kar trip ho raha hai
Coil sensor problem kar raha hai
@@chandrashekarazad2436 jo indoor me laga hota hai??
@@amanrc9283 yes indoor coil sensor and room sensor combined 👍
@@LG.Imtiyazhello❤
Inverter ac me bhi aaise hi krna h bhai
Nahi
Inverter ac me yahi problem a rhi h to kaise kiya jaye
Kaam ₹2 rupaya ka, aur paisa liya hoga ₹2000 😂😂😂
Bhi tu Mehmet krega to pata chlega ke paise kes bat ka he
Sir out door chalu karke
Aap Kam kar rahe hai esase
Koi dikkat nahi nahi ho gi sir
Nahi
Yahi problem thi R22 gas pressure 65 se 60 kar diya ab suction line to cool hone lagi par indoor me utna effect nhi aya aise hi oil jaisa nikla tha.pehle compressor bhi overload ho ke trip ho jata tha
Bhai ye thik kaise Kiya ye to btaya hi nhi please iss pe pura ache se video banao or btao ki kaise problems solve ki apne mere sath aisa ho gya hai or wo cooling nhi kr rha R 410 gas Mai
Oil choking Nikal Diya Sahi ho gya
@@AMRESH11TECH sir wtsp nmbr chahiye tha apka
Replay ker na bahi ho gawat hain