compressor tripping problem, thodi der compressor chalta hai band ho jata hai, compressor heat Kyu h

Поделиться
HTML-код
  • Опубликовано: 14 окт 2024
  • compressor tripping problem, 5 minutes chalker compressor band ho jata hai, compressor heat kyu ho rha hai, compressor jada ampare kyu le rha hai, compressor Strip problem, ac thodi der thanda karta fir garam hawa fekne lagta, compressor kaise check kare, ac condenssor flushing, capillary aur filter kaise change kare, ac thanda nahi ho rha kya kare, ac garam hawa fek rha hai, ac ka compressor kaise check kare, ac choke ho gayi kya kare, ac me gas kitani honi chahiye, patel and brothers, patelandbrothers, एसी बार बार ट्रिप कर रहा है,
    एसी का कम्प्रेसर हीट हो रहा है, पटलपटेल ऐण्ड ब्रदर्स, compressor heat problem in fridge, compressor heat kyu hota hai in hindi, compressor garam hoke band ho ja rha hai, compressor thodi der chalta hai band ho jata hai, compressor se awaj aa rahi hai, compressor heating problem, compressor nahi chal rha hai, compressor animation working, compressor heating fridge in English, compressor heating , ac ka compressor trip ker rha hai, fridge ka compressor trip ker rha hai, ac on hote hi voltage drop hota hai, ac chalu hota lekin thanda nahi karta,ac compressor tripping problem
    types of Compressor
    • Types Of compressor#कम...
    relay kya hoti hai
    • रिले क्या होती है, रिल...
    refrigeration cycle
    • रेफ्रिजरेशनसाइकिल# ref...
    Working Of Compressor
    • Working Of reciprocati...
    relay ka connection
    • रिले का कनेक्शन कैसे क...
    hvac plant
    • HVAC Plant# चिलर प्लां...

Комментарии • 861

  • @baburathore9000
    @baburathore9000 4 года назад +9

    very knowledgeable video and super uploading, Bhai very helpful for RAC engineer who are fresh in RAC line
    👍👍👍👍👍👍👍👍👍👍👍👍

  • @armysoldier8980
    @armysoldier8980 3 года назад +4

    Maan gaye bhai sahab....agar aap k jaisa technician mil jaye to kabhi bhi bina ac k nahi sona padega.

    • @jollyscaria1922
      @jollyscaria1922 Месяц назад

      @@armysoldier8980 gas low triping main reson power ampr checking durtok pm main gas los back prssure come ok cleing filter amper checking gas look gas tomuch tipinv hot and

  • @jaiprakashyadav9902
    @jaiprakashyadav9902 2 года назад +5

    Hi , I am working on Power and Air conditioning system from last 19 years in Defence, you explained all related faults very clearly, correctly and in a very cool manner that I recollected my 19 years experience during your video. Kudos..for the great work

  • @syedabbasali3673
    @syedabbasali3673 2 года назад

    Samjhane ka Tarika bahut achcha hai ful jankari ke sath ek Salah samjhane ke liye aap Jin shabdon ka istemal karte Hain UN shabdon ko Hindi aur English donon ka prayog Karen

  • @praveenmalhotra159
    @praveenmalhotra159 3 года назад +2

    Subscribed. Nice Video good information and very helpful

  • @indianankitpatel1135
    @indianankitpatel1135 Год назад

    Bhut hi acche se btaya apne

  • @kingofnawab3603
    @kingofnawab3603 2 года назад

    Sir app bahot acha samjha rhe ho

  • @gujjjargujjar737
    @gujjjargujjar737 3 года назад +2

    Sir please mujhe koi batado mujhe mera window ac kharab krna h new tbhi milega

  • @gouravparasher8271
    @gouravparasher8271 2 года назад +1

    Sir Meera window ac Lloyd ka hai raat koo kuuch deer ke liiye kabhi kabhi automatic cooling aani band ho jaati hai or phir auto chaalu kya ye common hai yaa koi problem ? Pls reply sir it's urgent I am a first user of an ac

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Kabhi kabhi bahut garmi hone ke Karan compressor overheat ho jata hai to trip ker jata hai jab compressor trip Hota hai to us samay cooling normal ho jati hai. Yr normal cause hai ager aur jada problem kare to comments kariyega

  • @ashtonvz8509
    @ashtonvz8509 Год назад

    Best explained... Great job.

  • @jamilahmed4157
    @jamilahmed4157 3 года назад

    Aap ke tips buhat umda aur karamad hote hain,
    MERA SPLIT AC 1 ya 2 Ghante tak chalne ke baad tripp hojata hai, specially dopahar 12 ya 1 bajay ke baad trip hota hai, bus fan chalta hai. Mehrbani kerke mere problem ko point out kerke solution bataden. Thanks.

    • @patelandbrothers
      @patelandbrothers  3 года назад

      Dopahar me bahut dhup hone ke karan aapka compressor band ho jata hai ager direct dopahar ki dhup aapke outdoor per pad rahi ho to us per kuchh chaanv ker dijiye

  • @yogeshsaxsena3326
    @yogeshsaxsena3326 3 года назад

    Brother aapke sare video gajab hain

  • @manishsingh4742
    @manishsingh4742 Год назад

    Sir Agar PCB nor working properly to bhi compressor trip hoga kya ..same problem 5 minut nice cool but then compressor trip and normal air flow...ols suggest

    • @patelandbrothers
      @patelandbrothers  Год назад

      Sabse pahle aapko ye find out karna hoga ki compressor heat hoker band ho rha hai ya aise hi, 5 minute me trip ke baad kitni der me start hota reply

    • @Adggg.
      @Adggg. 7 месяцев назад

      @@patelandbrothers अगर ट्रिपिंग के बाद खुद से ऑन नहीं होता है और अगर फिर मैं ऑन करता हूं तो ऑन हो जाता है लेकिन फिर ट्रिप कर जाता है तो क्या करना चाहिए?

  • @Jadhao389
    @Jadhao389 3 года назад

    Bahot badhiya bhau

  • @sarmad8965
    @sarmad8965 Год назад +1

    Amazing information 😮

  • @mihirpawar8930
    @mihirpawar8930 Год назад +2

    Sir i have lg 1.5 ton ac its compressor is tripping …first cycle it run for 10 min and then it gets trip within 4 min and again cycle goes on….the room temp is always plus 2-3 degree

  • @missmingling5620
    @missmingling5620 4 года назад +7

    Great video, keep it up👍 ur new frnd here😊

  • @hindrajlahare5940
    @hindrajlahare5940 3 года назад

    SAHI AC ENGINEERING PAHLI BAR YOU TUBE PAR MILA MUJHE THANK ALOT🙏🙏🙏🙏🙏

  • @SangeetaNigamCreative
    @SangeetaNigamCreative 4 года назад +4

    Great video plz.stay connected

  • @kingofnawab3603
    @kingofnawab3603 2 года назад

    Sir app se ekk questions hai mujhe batao ki gass charges me kon line khan use hoga sir please tell me sir please me isme bahot jda confused hun sir please

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Gas charging hamesha low side se karte hain Matlab aapko gas charging ke samay suction line me charging line ko lgana hai ya fir aap aur kuchh confuse hain to poora question likhe

    • @kingofnawab3603
      @kingofnawab3603 2 года назад

      Sir me appse ye puch rha hun ki har gash alag alag hota hai to gaisline jo hoti hai wo alag alag lagti haina to wahi me puch rha hun ki kon se gash me kon line lagega sir

  • @dushyantkumarchandel8005
    @dushyantkumarchandel8005 3 года назад +2

    Very nice explanation...👌👌👌

  • @dushantinsaan8435
    @dushantinsaan8435 4 месяца назад

    Lloyd window AC purchased 2 yaers ago.kisi bhi temp pe set karne se 5-7mim chalke compressor band ho jata h bs fan chalta h.plz guide me

    • @patelandbrothers
      @patelandbrothers  3 месяца назад

      Sabse pahle ye find out karna padega ki compressor senssor se band ho rha ya high ampare hoke tab hum kuchh bta payenge

  • @divjotsingh3904
    @divjotsingh3904 2 года назад +1

    Sir hamera room pe mitsubishi heavy industries ac lga hua hai usme compressor drip kr rha hai toh plzz aap btaye kya kre
    Hmne kisi wrkr ko bulaya usne bola gas km haii
    Aab toh gas b dalva lyi fr b same prblm a rhi haii
    Plzz suggest kre
    Boht pareshsn hai hm
    Sari raat bche so nhi pate

  • @greenopgirl1157
    @greenopgirl1157 3 года назад

    बहुत ही बढ़िया सर

  • @rupag1849
    @rupag1849 3 года назад +2

    Sir mera o carrier 1.5 ton ac, Once ac on kare after 10 mini AC automatically totally off then automatically on
    whats is the problem sir plz bathaye

  • @VijaySingh-fb6uf
    @VijaySingh-fb6uf Год назад

    Indoor to outdoor coppr pipe conection ager 3 feet ya esse kam ho to koyi dikkat hota hai kya

    • @patelandbrothers
      @patelandbrothers  Год назад

      Haa discharge pressure badhane lagta hai, jisase ac thodi der chal chal ke band chalu hota hai,

  • @syedabbasali3673
    @syedabbasali3673 2 года назад

    Ek jankari Den please old model dedh tan ka window AC hai Lancer ka kya uska compresser Badal sakta hai

  • @432yssony
    @432yssony 2 года назад

    Bhai ji please suggest Karo : Mera Whirlpool split 1.5t ac trip karta hai. Actually kuch din pahle condenser change hua tha uske baad se hi ye dikkat aani shuru huyi hai. 10-15 minutes chal ker trip ho jata hai. Or ampere bhi jyada le raha hai ab. 1900watt tak bhi ja raha hai load ab. Pahle gas Kam Kari thi technician ne fir sahi chalne lga tha load bhi 1250 watt lene lga tha per cooling nahi ker rha tha. To dobara gas daali per trip ker rha hai load 1800-1900 watt le raha hai. Ac ka load actual me 1450 watt tha papers me catalogue me waise

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Gas dalne se pahle sahi se vacuume liya tha ya nahi

  • @RajKumar-pp9ll
    @RajKumar-pp9ll 3 года назад +2

    graet points Sir, keep it up

  • @JunaidKhan-ik5yw
    @JunaidKhan-ik5yw 2 года назад

    Sir mera haier ka 1.5ton window ac h yei cooling to krta h but kbhi kbhi cut ho jata h compressor jhatke sei aur fir ac band krke backside paani dalke ac cooling achi krta h isme kya problem h iski service krva kei sahi hojaega ya koi aur issue h

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Service karwa lijiyega aur voltage check karwaye ki kam jada hota hai kya

  • @manishsingh4742
    @manishsingh4742 Год назад

    Sir want to talk with you regarding window ac if possible pls help and guide ...

  • @nrusingharay7242
    @nrusingharay7242 Год назад

    Sir namaskar ji career window AC durakool on karnaka bat cameras on nahi hota he triphotaha kiya karonga

  • @pradhumansingh585
    @pradhumansingh585 2 года назад

    Plz Sir iska ans dijiye mechanic bulata hu sub alag alag preshani btate h

  • @sahabsingh3921
    @sahabsingh3921 2 года назад

    Very good information sir

  • @hafizmuhammadusmanitfaqqad3690
    @hafizmuhammadusmanitfaqqad3690 3 года назад +1

    Mera ac haire ka ha 18000 btu vo sirf 30 secnd chalta ha or us ka compreser band ho jata ha ma nay us ka raning copester bhi chanj kiya magar vo phir bhi 7 empaer lay kar band ho jata ha us ka kiay fold ha????????? Plz reply

    • @patelandbrothers
      @patelandbrothers  3 года назад

      jab ompressor band hota hai to fan cbala karta hai ya wo bhi band bo jata hai

  • @Motivate111
    @Motivate111 2 года назад

    Sir mene lloyd ka ac new liya ha 1.5 ton inverter.. me 28 pe chalata hu to 5 10 min cooling krne ka baad compressor off ho hata ha normal hai ya koi problm ha sir ..?

    • @patelandbrothers
      @patelandbrothers  2 года назад

      jab room ka temperature badhta hai to fir compressor chalu ho jata hoga waise koi problem aapki ac me nahi hai fir bhi aap neeche link per jaker video dekhiye poora process samajh jayenge,
      ruclips.net/video/LIcvENp1rxQ/видео.html

    • @Motivate111
      @Motivate111 2 года назад

      @@patelandbrothers sir ek or problem ha ac me .. chill mode pe itna cooling nahi krta jitna dry mode pe krta ha dry mode pe bht jyada colling krta ha

  • @praveenmalhotra159
    @praveenmalhotra159 3 года назад +1

    Nice video, Hitachi Window AC switch off automatically at night, works fine during the day. Filter was dirty blocking the airflow.
    Subscribed 👍

    • @patelandbrothers
      @patelandbrothers  3 года назад

      poora ac band ho jata hai ya sirf compressor

    • @praveenmalhotra159
      @praveenmalhotra159 3 года назад +1

      @@patelandbrothers Sirf compressor

    • @patelandbrothers
      @patelandbrothers  3 года назад +1

      aapka compressor kafi der chalne ke baad heat ho rha hai service na hui ho to karwa lijiye, room poora packed hona chahiye, aisa bhi hai kya ki night me light ka voltage kam hota ho

    • @praveenmalhotra159
      @praveenmalhotra159 3 года назад +1

      Thank you for your valuable feedback and advice. Service could be the culprit behind the anamoly.

    • @poojawalia8251
      @poojawalia8251 3 года назад

      @@patelandbrothers hmm

  • @muhammadjafer
    @muhammadjafer Год назад

    Sir
    I hve 1 split 1.5t ac
    Its work f9 in night and taking mor amp asss compair normal.
    But in day its trip aftr 20mnts
    What problm in my ac?

    • @patelandbrothers
      @patelandbrothers  Год назад

      Direct sunlight on the outdoor unit reads that if this happens, the discharge pressure of outdoor increases due to direct sunlight, the compressor gets heat due to increase in discharge pressure,this is normal case

  • @RajnishKumar-4791
    @RajnishKumar-4791 2 года назад

    Good experience and good explanation

  • @shaktisuccess0369
    @shaktisuccess0369 3 года назад +1

    Sir, humara lg ka ac hain usme outdoor unit jab band hota hain to jor se khattt.. esi awAz ati he , to kya problem ho sakta hain? Plz bataiye

    • @patelandbrothers
      @patelandbrothers  3 года назад +1

      compressor 3 nut bolt se bandha hota hai un nut bolt me rubber ke gromet pade hote hai kahi wo gromet kat to nahi gaye

  • @nazranaislam7908
    @nazranaislam7908 2 года назад +1

    Mera window ac h line toh thk h par ac chalta h phr slow ho jaata h phr se chalta h phr compressor slow ho jaata h ..earthin ka prblm bhi ho sakta h kya..kyun k jahan se earthin liya h woh line me bohat load h

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Haa ager voltage 190 volt se kam ho jata hoga to bhi aisi problem aati hai, night me jada problem hoti hai kya

    • @nazranaislam7908
      @nazranaislam7908 2 года назад

      @@patelandbrothers din me hota h ..neutral kya hota h sir

    • @patelandbrothers
      @patelandbrothers  2 года назад

      @@nazranaislam7908 aap ac chalu rahte hi voltage check karwaiye

  • @BaljinderSingh-pn1mm
    @BaljinderSingh-pn1mm 2 года назад

    Thanks bhai ji for valuable information

  • @RahulSharma-qj5wq
    @RahulSharma-qj5wq 4 месяца назад

    Hello, LG non inverter split 1.5 AC, compressor trip problem, 5 min chalta hain uske baad band ho jata hain, no cooling only fan running, service karwa li, capacitor change karwa liya, kya problem ho sakti hain, pls guide, outdoor unit chanv main hain

    • @hajiamirsajjad1978
      @hajiamirsajjad1978 4 месяца назад

      De.

    • @patelandbrothers
      @patelandbrothers  4 месяца назад

      Jab 5 minute chalta hai toh cooling hoti hai aur ampare metre lga ke check kariye jab band hone wala hota hai toh us time ampare kitna hota hao

  • @amitchaudhary3985
    @amitchaudhary3985 3 года назад

    Sir mere pas 1.5 ton window ac. H. Ac 6 min tk shi chlegi uske bad 3 min k liye trip ho jayegi. Kya problem h bhai ji. Please btaye

    • @patelandbrothers
      @patelandbrothers  3 года назад

      grill kholker dekhiye coil me senssor laga hoga us senssor ko coil se hataker hanth me pakadker rakhiye phir ac chalaiye aur dekhiye kitani der chalta hai

  • @mayankboss319
    @mayankboss319 3 года назад +1

    Sir pichle 1 mahine se split AC only 5-10 minutes chalta hai phir baad mein cutoff ho jata hai.... phir 1-2 ghante bandh rakhne ke baad phir 5-10 minutes chalegaa phir cutoff ho jata Bahar Outdoor Unit par haath lagaya toh bahut zyadha garm ho raha tha .kal koi technician se AC ki service bhi kara li,Condenser bhi change karwa liya or Rely bhi change karwa li par kuch bhi nahi hua ....sir please bataiye ab kya kara jae???

    • @patelandbrothers
      @patelandbrothers  3 года назад

      Puri gass nikal ker capsliry change karwake achche se vaccume karwaker wapas fir se gass dalwaiye

  • @shailendrashukla6548
    @shailendrashukla6548 Год назад

    Very good 👍🌹

  • @indranilbarik5123
    @indranilbarik5123 3 года назад +1

    Bhaia excess gas tripping karta hain kya aur amp zyada hote jara phir trip hora !!! Aur bhaia r22 ka pressure kitna hota hain running pressure ??

    • @amintechnical7462
      @amintechnical7462 2 года назад

      ruclips.net/user/shortsVhp07307c9Q?feature=share

  • @indralatasharma7752
    @indralatasharma7752 3 года назад

    Bahut hi achcha bataaya sir

  • @bajaurf4u703
    @bajaurf4u703 4 года назад

    Buhat acha 🌹Mene ap ko dust bana liya🌹

  • @imrannafees8289
    @imrannafees8289 3 года назад

    Good video Allah apko tarriqi de

  • @FARAHTAli777
    @FARAHTAli777 4 месяца назад

    New compressor daikin non inverter ac 1.5 ton me kuan sa dlbaye

  • @SandeepSingh-sj3pn
    @SandeepSingh-sj3pn 3 года назад

    Brother isme pcb ki bhi problem aa skti h

    • @patelandbrothers
      @patelandbrothers  3 года назад

      waise pcb ki problem aayegi to compressor 5-10 minute nahi chalega ha ye ho sakta hai ki jo pcb me temprature sensor lga hota hai wo fault ho,

  • @ApnaJandNajjar
    @ApnaJandNajjar 4 года назад

    Good work man 👍🔔🙏wapas

  • @divyanshchandak476
    @divyanshchandak476 3 месяца назад

    I purchased new Split Inverter AC 1 Ton of Voltas and from the time is has been installed I am facing Compressor tripping problem in 3-4 minutes please advise

    • @patelandbrothers
      @patelandbrothers  3 месяца назад

      What is electric voltage condition

    • @divyanshchandak476
      @divyanshchandak476 3 месяца назад

      @@patelandbrothers Sir Voltage is alright because 2 same model of AC has been installed in two different rooms . One is working fine but there is problem in other . After engineers visit by voltas service team .. they are telling that they have mailed for replacement but already 10 days have passed and there is no response. Please suggest what should I Do

  • @abhishekjain9503
    @abhishekjain9503 4 месяца назад

    Best explained

  • @BLOGBass
    @BLOGBass 2 года назад

    Sir mere 2 ton ke compressor ke copper or compressor ke cyclender per licked current aarha ha ky problem ho sakta h ?

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Compressor per terminal lage hote hain unko check ker lijiye kahi Compressor ki body se touch to nahi ho rahe hain

    • @BLOGBass
      @BLOGBass 2 года назад

      @@patelandbrothers or sir mene 450 v supply per lagaya hu shop per kahi usse tho nahi ho raha hoga ?

  • @Fusionplate
    @Fusionplate 2 года назад

    mera Super general split ka outdoor dhad dhad karke din mein bandh hora tha, urban clap se technician ko dikhaya usne poora service kiya...uske kuch din baadh theek chala...ab firse sane problem ab toh raat mein bhi hora hain...mujhe stab mein voltage magar 80 ke niche uska kaanta dikh raha...kya problem ho sakta hain.. please reply

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Aapke yha wining me kahi loose contact hai ya kahi se Volta dropping ho rahi hai

    • @Fusionplate
      @Fusionplate 2 года назад

      @@patelandbrothers technician ne ac poora check kiya acche se outdoor unit ka capacitor aur sab kuch...sab thik hain...par usne bola high ampere outdoor mein aara hain...isi wajah se outdoor unit heat hoke bandh hota hain..khass karke din mein..magar kal raat mein bhi ho gaya yeh...aur mera stab 80 mein uska point hain ruka huwa...toh ac thik hain?? Voltage ya stab kharab hain?? Thanks for the reply

    • @patelandbrothers
      @patelandbrothers  2 года назад

      @@Fusionplate aap ek bar Bina stabilizer ke chla ke check kariye ager stabilizer voltage jada bnayega to bhi ac band ho jayega

    • @Fusionplate
      @Fusionplate 2 года назад

      @@patelandbrothers ji maine bina stab ke chalaya...thik chala..toh kya problem so sakta hain stab mein?? Pps reply

  • @zahidchachakakitchen3637
    @zahidchachakakitchen3637 3 года назад

    Bahut badiya bataya

  • @gulabrbbani2261
    @gulabrbbani2261 4 года назад

    Sir please answer me.ager koi 500 ton ki chiller ho centrifugal or us me 134a gas hoto to wah chiller kitna pressure pe jayega to LP or Hp pe trip karega ..last pressure Kya hoga dono situation me.

    • @patelandbrothers
      @patelandbrothers  4 года назад +1

      134a gas hai to hp 150+ psi per hold ho jayega ager pressure controll ho gya to theek otherwise 160 psi pahuchate hi chiller hp per trip ho jayega, aur LP 25 per low Evapurator prassure per hold rahega, control huwa to theek otherwise 22 psi ke neeche jate hi low Evapurator prassure per trip ho jayega, ye lagbhag sabhi company ka parameter hota hai,,

    • @gulabrbbani2261
      @gulabrbbani2261 4 года назад

      @@patelandbrothers thank you very much sir Dil se..Mai bahut paresan tha is ke liye..

    • @patelandbrothers
      @patelandbrothers  4 года назад +1

      no thanks plzz subscribe my channel 🙏🙏🙏

  • @shreyasdharmadhikari3505
    @shreyasdharmadhikari3505 3 года назад +2

    Hi sir,
    I have carrier ac austra model(1 ton ). My ac showing error E1. Called customer care they changed outdoor pcb (was working fine hence complaint closed). But after 1 week same problem is occurring. Please guide.

    • @patelandbrothers
      @patelandbrothers  3 года назад

      waise e1 is comunication error in out door pcb, you call costumer care again and claim him

  • @Agri_Changer
    @Agri_Changer 2 года назад

    Sir i am learners, muje apke pass se training leni he . Aap kaha se ho. Ya fir online sikhate ho

  • @BharatKuhikar
    @BharatKuhikar Год назад

    Sir dubbal door fridge ka kam cooling me kya kya problem ho sakti hai pleas ek video banaye

  • @vrcvlogger
    @vrcvlogger 2 года назад +4

    हमारा स्प्लिट AC जो कि डेढ़ टन का है उसका कंप्रेशर 3 मिनट चलता है और तीन ही मिनट बन्द रहता है और अगर उसको ड्राई मोड में चलते है तो कंप्रेशर ठीक चलता है मतलब ठीक चलता है तो ठंडक भी ठीक होती है पर cool मोड 3 मिनट ही चलता है अगर ड्राई मोड में कंप्रेशर ठीक चलता है तो फिर cool मोड में दिक्क्त क्यों करता है ऐसा क्यों है जबकि बैक प्रेशर 65 है और स्टैंड प्रेशर 165 से 170 है

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Indoor unit me 2 sensor lage hote hain usame se Jo copper wala sensor Hota Hai usko check karwaiye

    • @sahilchamp1012
      @sahilchamp1012 3 месяца назад

      Bhai same condition hai 4 mint on rhta hai aur 3 mint off rhta h

    • @viknitu1
      @viknitu1 3 месяца назад

      Mera indoor ac 7 minutes chalta hai or 3 minutes band rahta hai please bataye kya issue ho sakta hai ?

    • @kapoorji.5539
      @kapoorji.5539 2 месяца назад

      @@viknitu1 same issue. But mere me yeh tab hota jab gas low hojati.

  • @ChandraDevAgrahari
    @ChandraDevAgrahari 4 года назад

    Good knowledge bhaiya ji

  • @vijaygupte2608
    @vijaygupte2608 3 года назад

    Sir mene dusra ac shop me uper manjil me lagwaya jab mai dono ac ko chalata hu to niche wala ac se garam hawa aata h mai kya karu sir kisi ne kaha ki aap 130+ ka steplizer lagwa ke aap bataye kya karu

    • @patelandbrothers
      @patelandbrothers  3 года назад

      continue garam hawa aati hai ya kabhi kabhi thanda karta hai outdoor directly dhoop me hai kya jab ac chalate hain us time voltage kitna rahta hai aur ek ac chalate hain tab bhi same problem rahti hai kya reply me fir mai problem bta paunga

  • @Shariq26
    @Shariq26 2 года назад

    45 micro Farad ac me install tha mechanic 50micro Farad laga diya hai... uske baad se outdoor bht awaaz kr raha or sahi se chal bhi nahi raha and outdoor trip bhi ho raha h... koi solution de

    • @patelandbrothers
      @patelandbrothers  2 года назад +1

      45 mfd ki jagah 50 mfd lga diya isase koi fark nahi padta, aap voltage check karwaiye, aur ye btaiye ki aapka ac Kitna purana hai

  • @amishasingroha3102
    @amishasingroha3102 3 года назад

    Humne nya ac khrida h hitachi ka 1 ton ka 5 chlta h phir compressor down kya kre sir

    • @patelandbrothers
      @patelandbrothers  3 года назад

      Aapki ac abhi waranty me hai isliye aap company ko complain ker dijiye

    • @amishasingroha3102
      @amishasingroha3102 3 года назад

      @@patelandbrothers garanty m h sir

  • @NARENDERKUMAR-mehan
    @NARENDERKUMAR-mehan 2 года назад

    Sir, I have LG Dual Inverter 1.5 ton split AC. It was working fine since it was installed two years back. But now a days it has some malfunction. Actually when it runs for 1-2 minutes after switch on, RCCB (32A, 30mA) on my main MCB panel trips off. When I put the RCCB on and restart AC, it trips RCCB off again with in 2 minutes. Sometimes it runs for maximum 20-30 minutes then again starts tripping off RCCB.
    7.5 kw stabilizer is installed in my house for complete house load. Stabilizer is not overloaded by household appliances.
    This AC is not repaired in any condition till now.
    It was serviced two months back.
    This RCCB tripping problem is in day as well as in night also.
    No direct sunlight on outdoor unit.
    Sir please suggest what could be the probable causes and their solutions also.

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Whenever your air conditioner runs continuously for 20 to 30 minutes then at that time you have to pay attention to whether your air conditioner properly is working or not. It may also happen that when your air conditioner is running, there is a slight leakage of earth in it which is tripping the RCCB, please check properly by qualified technician

  • @mohammadasifkhan4188
    @mohammadasifkhan4188 Год назад

    Same pro ho rhi h sir 15 mnt chalta h compressor heat hokr band ho jara h capacitor chenj kr diya condenser bhi bhut ganda tha clean kr diya gas bhi shi h voltage bhi shi h fir bhi trip ho rha h fan moter chenj krna pdega kya 😊

    • @patelandbrothers
      @patelandbrothers  Год назад

      Fan motor na change kariye fan ka jo capacitor hai usako change kariye fir bhi nahi hota hai to btaiyega

  • @gurdialswalia8308
    @gurdialswalia8308 3 года назад

    Very nice suggestion

  • @dreamgirlindia.97
    @dreamgirlindia.97 3 года назад +7

    Supper voice 👍

  • @abhaypandey2794
    @abhaypandey2794 2 года назад +1

    Sir I'm facing the problem of compressor tripping at afternoon but it works fine at night and my compressor is inside the sade , plzz tell me some solution sir

    • @patelandbrothers
      @patelandbrothers  2 года назад

      There is no technical problem in your air conditioner, when there is too much heat then such problems come

  • @lgltd394
    @lgltd394 3 года назад +14

    Aapko ek point aur add karna chahiye tha ki ager compressor me oil kam hoga to bhi compressor heat hoga

    • @sushildubey7973
      @sushildubey7973 2 года назад +1

      Lakin bhai ye sautition bhoot km aati h

  • @praveenmalhotra159
    @praveenmalhotra159 Год назад

    Hitachi window AC works fine with fan Speed medium and low but trips at fan speed High. Any solution?

  • @khanairconditioner6744
    @khanairconditioner6744 Год назад

    Sir daiken ka non inverter Split AC h fan speed theek h or sarvice ki koi dikkat nhi h fir bhi compressor trip kyu maar rha h

    • @patelandbrothers
      @patelandbrothers  Год назад

      Kitani der me trip ho jata hai. Aisa to nahi ki rat me sahi chalta ho din me trip marta ho

  • @AjaySingh-rg8yi
    @AjaySingh-rg8yi 4 года назад

    bhai aap bhut gret ho

  • @asharaf123mirfa9
    @asharaf123mirfa9 3 года назад

    Siplet ac ki secshn or discharge heet kb hoti h

    • @patelandbrothers
      @patelandbrothers  3 года назад

      split ac ka suction aur discharge line heat nahi hoga, ager outdoor open karke bilkul compressor se jo discharge line nikalati hai usako tauch karoge to heat rahega waise aapke ac me problem kya hai

  • @maheshprajapati7696
    @maheshprajapati7696 3 года назад +2

    Sir...I purchaged new Blue Star 1.5 Ton 3 Star Inverter Split AC (Copper,) IC318RBTU 3S before 2 years. It works completely good till now but recently i have made wet service before 15 days and then my problem started.at night when i start ac at 26 c.normally outdoor compressor starts and proper cool air comes but after 20 minutes compressor stops autometically and cool air stops then i set tempracture 25 c.through remote then outdoor compressor starts.. (
    and after 20 minutes, it also stops automatically. Then little moisture air comes. I am harresed bcoz my sleep disturbs. My inverter AC works like non inverter AC
    1..It s any sensor or compressor problem ?
    2.How to resolve it ?
    3.Tell me sir about all sensor cost pls...

    • @patelandbrothers
      @patelandbrothers  3 года назад +1

      You run continuously during the day and notice, what same problem is coming and when the compressor is stop, does any alarm come as you are telling, it does not seem that the sensor of the AC is not fault, then tell me

    • @maheshprajapati7696
      @maheshprajapati7696 3 года назад

      @@patelandbrothers
      Thank you Sir..I am from Gandhinagar,Gujarat.
      I already complained to Blue star company.Technician came and checked only and voltage and told me that my AC is ok.and there is no preblem at all.there is no error displays on indoor AC screen.
      I dont know the exact problem sir but I am dam sure that something has gone wrong....pls guide me sir...
      I am harrased due to oftern cut off compressor even i have Inverter new AC...

    • @maheshprajapati7696
      @maheshprajapati7696 3 года назад

      @@patelandbrothers i tried...same problem....

  • @sahilchamp1012
    @sahilchamp1012 3 месяца назад

    @jaiprakashyadav9902 sir blustar 1.5 ton ka split ac h 4 mint chalta h aur 3 mint off rhta h sir kya reason ho sakta h plz rply

    • @patelandbrothers
      @patelandbrothers  3 месяца назад +1

      Poora off ho jata hai ya sirf outdoor

    • @sahilchamp1012
      @sahilchamp1012 3 месяца назад

      @@patelandbrothers sir sirf out door har koi alag alag salutations bata rha h aap bataiye kya problem ho sakti h sir 😞

    • @patelandbrothers
      @patelandbrothers  3 месяца назад +1

      @@sahilchamp1012 indoor ki cooling coil me ek senssor lga hoga usko coil se nikalker matlab bina coil me tauch kare tab chalaiye aur btaiye kitani der chalta hai, ek senssor cooling coil ke bilkul front me rahta hai usako nahi doosra jo pcb lagi hoti hai usake pass uper coil ke ander dla hoga senssor bhi copper ka hi hota hai usako

    • @sahilchamp1012
      @sahilchamp1012 3 месяца назад

      @@patelandbrothers ok sir shukriya rply dene k liye kafi time se main pareshan hu is problem se ....

    • @sahilchamp1012
      @sahilchamp1012 3 месяца назад

      @@patelandbrothers sir coil sensor hata k check kr liya abhi bhi wahi problem face aa rhi h but ab compressor 3 mint se badh kr 6 mint chal rha, 3 mint band rhta h
      sir pcb check krare kya
      sensor v bad gai h......ya relay kharab ho gai h 3 mint me suply cut kr rahi...... Ya kahiye to 1 baar capister change kr k dekhe aap suggest kriye kiya kre .....

  • @nitin4322
    @nitin4322 2 года назад

    Hello sir. Mene 1.5 ton 3 star window ac liya h 1 month phle. Me use 24 pe chalata hu wo starting me max. 10 compressor on rrhega uske bad band ho jata h fir 5 min bad on hota h bs fan chalta h or fir 1 min bad compressor bnd ho jata h . Yahi continue rheta h raat bhar.or na room itna cool hota h bs samne baithe rhne walo ko thanda lgata h wo bhi jb compressor on hota h. Or iski left side bhi cool rheti h. Please suggest me kya problem hogi

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Aap apne yha voltage check karwaiye jab compressor chalta hai to voltage dropping to nahi ho rahi hai

  • @HemantKumar-ku2bu
    @HemantKumar-ku2bu 3 года назад

    2mint comp.chal kr band ho jata h 5mint bd wapish chalu ho jata h vollate ki Ac h 1.5 tonn ki onenwetar plzzz repyal dena

    • @patelandbrothers
      @patelandbrothers  3 года назад

      indoor unit ki pcb me senssor lga hota hai usako badal ker dekh lijiyega, jab 2 minute compressor chalta hai to cooling karta hai ki nahi aur ye bhi btaiye ki jab compressor chalta hai to voltage kam to nahi hota hai,

  • @manjarishrivastava3371
    @manjarishrivastava3371 2 года назад

    Compressor replace krne ka kya charge lgta h

  • @noyanrajput7332
    @noyanrajput7332 Год назад

    Sir blue star non inverter 1.5 ac(MODEL-FA318DLU/2022) Temperature 26-30 me chalayenge to 1 ghanta ke ander aur 24 me chalate he to 2-3 ghanta ke baad automatically band hojata he.pehle temp.16 pe chalate the toh compressor ka speed & sound jyada rehta tha aur 24 pe compressor thoda kam ghur raha tha sound b kam ata tha abb 16 pe lagao ki 24 temperature me lagao Compressor running ka speed & sound same rehta he AC temperature change karne se compressor running ka sound & speed me koi change nehi ata he 24 pe jesa sound araha tha beise araha he. Plz help

    • @patelandbrothers
      @patelandbrothers  Год назад

      Cooling ho rahi hai ya nahi, kewal sound ki problem hai

    • @noyanrajput7332
      @noyanrajput7332 Год назад

      @@patelandbrothers sir cooling thik horaha he but automatically off ho jata he 2-3 hour ke baad

    • @noyanrajput7332
      @noyanrajput7332 Год назад

      @@patelandbrothers error b nehi ata he kuch fir se remote se chalu karna padta he

    • @patelandbrothers
      @patelandbrothers  Год назад

      @@noyanrajput7332 indoor unit bhi off ho jata hai

    • @noyanrajput7332
      @noyanrajput7332 Год назад

      @@patelandbrothers hmm sir 2 line yellow baar rehta he indoor display me. Remote se on karne se fir se chalu hota he 2-3 hour chalta he

  • @praveenmalhotra159
    @praveenmalhotra159 Год назад

    I have a Hitachi window AC no problem at fan speed Medium, but at fan speed High, it stops after about fifteen minutes and then restarts after five minutes of shutdown.
    What could be the problem?
    Any suggestions?
    Thanks

  • @Harshityadav-wb5si
    @Harshityadav-wb5si 2 месяца назад

    good

  • @RashidAli-qs9vh
    @RashidAli-qs9vh 3 года назад +1

    Sir g
    Ak Daikin ac hai none invetor jiska compressor 10 ya 15 minute ke bad trip ho raha hai
    New compressor dala hai mene gas 110 psi dale hai r 32 gas charging ki hai

    • @patelandbrothers
      @patelandbrothers  3 года назад

      out door ka fan bhi band ho jata hai ki kewal compressor

    • @RashidAli-qs9vh
      @RashidAli-qs9vh 3 года назад

      @@patelandbrothers only compressor off ho jata hai

    • @patelandbrothers
      @patelandbrothers  3 года назад

      @@RashidAli-qs9vh bhai aapka compressor kitane ampare le rha hai plz check

    • @RashidAli-qs9vh
      @RashidAli-qs9vh 3 года назад

      @@patelandbrothers starting me 6 se start ho raha hai
      10 minutes chalne ke bad me 14 , 15
      Tak pahuch ne par trip ho raha hai

  • @AbhishekTiwari-rq3sp
    @AbhishekTiwari-rq3sp 2 года назад

    Sir mera 1.5 ton ka haier ka window ac hai 8 years old 15 min chalne ke baad ampere bahut jada badh jaa rha hai aur 10 kilowatt ka stabilizer trip ho ja rha hai jo kj mere ghar ka pura load 5 kilowatt hi hai

  • @Prekshaclasses
    @Prekshaclasses 3 года назад

    Sir window ac ka compresaor 1minute chalne ke baad band ho jata he. Phir 10 minute ke baad phir start ho kr 1 minuter chalne ke baad bund ho jata he kya kre please batae

  • @khojasw
    @khojasw 2 года назад

    Mera window ac starting k baad trip ho jata hai...lakin jaise jaise raat hoti hai...jo 27 par trip to hai...wo 25 phir 21 ho jaata hai kya problem hai...is ac ko 21 par set kiya huaa.hai.
    Please reply

  • @kuldeepkumar-yo4cp
    @kuldeepkumar-yo4cp 2 года назад

    Sir agar fan motor bhi nahi chalte to compressor trip hoa jata hai kya

    • @patelandbrothers
      @patelandbrothers  2 года назад

      Ager fan motor nahi chalega to compressor trip ker jayega

  • @Al-rx1vs
    @Al-rx1vs Год назад

    In my window AC no water coming out from back side also compressor restart after five minutes recently change remote panel kindly advise what to check and repair

    • @patelandbrothers
      @patelandbrothers  Год назад +1

      How mamy years old your aircondotioner

    • @Al-rx1vs
      @Al-rx1vs Год назад

      @@patelandbrothers issue was related to temp sensor, while replacing the remote sensor panel tevhinician shifted it too away because of which compressor was doing on and off fast

  • @akberkhan3071
    @akberkhan3071 3 года назад +1

    Sir ..Compressor me oil ki matra km hogi tb bhi compressor over hit ya trip hoga

  • @punamthakurmea
    @punamthakurmea 4 года назад +1

    30 like, very nice

  • @khushirajput7764
    @khushirajput7764 3 года назад +3

    Thanku👍

  • @theskelitn263
    @theskelitn263 3 года назад

    Ac Kya cool mode pe 16 mein dene ke bad bhi automatic compressor 20 30 minutes mein band hota hai Kya?

  • @tamanna4092
    @tamanna4092 3 года назад

    Sir godrej window ac m bht cut lg rha h hr 5 mint m plz help kre

  • @anand2331
    @anand2331 3 года назад

    knowledge hai bro

  • @azaanashraf9233
    @azaanashraf9233 3 года назад

    Indoor unit ke blower ki Speed kam hone pe aisa falt ho sakta hai ya nahi

    • @patelandbrothers
      @patelandbrothers  3 года назад +1

      indoor unit ke blower ki speed kam hone per suction line me ice aane lagegi lekin compressor continue chalta rahega

  • @kajalagrawal3399
    @kajalagrawal3399 3 года назад +1

    good and very useful video

  • @punisherp7773
    @punisherp7773 3 года назад

    Sir mera ac ka outdoor unit har 5 min m on off hota or cooling kr rha h pr off bhi ho raha h maine aaj evaporator coil clean bhi ki h water se uss ke baad se on off hora

    • @patelandbrothers
      @patelandbrothers  3 года назад

      off hone ke kitani der baad fir se chalu hota hai, aapne evaporator clean kiya ya outdoor ka condenser