Naeem bhai aap electronic expension valve ke upar video bnao uska kya kaam ho ta he kis trike se kam karta he our use kese check karte he ye sahi he ya kharab
Pls tell that after flushing how to check the recommended compressor oil level that should be in the system for proper lubrication of compressor parts for prolong life. Pls also tell me that after each gas leakage repair, is it necessary to makeup oil level and how much fresh oil should be added. Thanks
I have read it somewhere that half liter compressor oil is required in 1.5 ton AC. So in my view if a AC gets 2 to 3 times leak then oil make up become necessary otherwise compressor may get seized.
@@khawajajodat8763 wud yu also k ow a good tech icia. For hiar hi window 1.5tone who cud want capillary..change filtee inside in Delhi Mehrauli area nebe reasonable in his charges nd if gas doesnt then can he avoid gaa recharge lime in this vedio ..though they used the cylinder
Hello brother I am from India 🙏 Brother aapse request hai ki aap ek video banae capillary data per aur yah bhi bataen window mein aur split mein capillary data mein kya fark hota hai , Aur jab bhi aap capillary data ke bare mein bataen to yah bhi bataen capillary single line leni hai ya FIR double line leni hai 🙏 Brother aapse request hai 🙏 Deep freezer 600 litre mai evaporator ki length kitni honi chahie aur condensar mein length kitni honi chahie fit ke hisab se bataiye aur capillary data bhi bataiye Aur capillary kitni lagani chahie single ya double , aur compressor kaun sa lagana chahiye 🙏
Naeem bhai main mohammad adil india 🇮🇳 se.Naeem bhai window ac ke pure system ko nightrogen se flush kaese karte hai uske upar bhi video bana dijiye bhai plz
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤ mashallah zabardast bhaijaan naeem bhai nera naam bhi shahzad h India Delhi se kese h aap har video aap ki dekhte h ek question tha k aap ne iski gas west kyo nhi ki na outdoor flesh kiya mere Ac m choking huyi thi mene campressor cheng kiya tha but fleshing nhi ki phir dubara sari gas west ki or is tarha se fleshing ki so aap ne kyo fleshing ki campressor cheng kiya tha kiya ya bina cheng k bhi ye problem aajati h and aap ne outdoor kyo nhi fleshing kiya or gas west kyo nhi ki plzzzzzzzzzzzzz reply
Jo gas store ki hay us say bhi yahi process karna zyada behtar nahi tha ? Amount of gas to wohi laga ..my point is kay wo gas is oil ka sath chali hoi thi , fresh gas charge hojati ? ? ? Kiya khayal hay apka ?
Meri na cheez raey ma is say zyada aham yah hay shayad kay reverse route of gas flow clear everything more then normal flow route of gas .🙏 keep your good work up 👌👌
I have some questions 1) Discharge valve of oudoor unit was closed while doing flushing?2) Can we do flushing of indoor unit with air by another compressor then attach the discharge pipe and do vaccum by vaccum pump? 3) There is a loss if compressor oil , if not added some oil in compressor will it not damage the compressor?
Dost Jaruri hai kya aese case me Aaj indor hi chowk ho or outdoor sahi ho,,,kya chowking condition me jab ice luquid line per aa ja rhi thi tab guge miter stable tha ya variable please bataiye
Lekin jo oil pipe se bahir aya hai uski waja se comprossor heat nahi ho gha kya.? ...ya is se koyi farak nai pardta..... Jo oil bahir nikla wo compressor se kam ho gya ..... Kya gass zaya kar k compressor oil poora karna chahiye ya aise hi kaam chal jaye gha .....?
Compressor ma oil dalnay ki zarrorat nahi ..zyada behtar tareeqa yah hota kay jo gas thi usi say flush kartay or new gas charge kartay ..choking gar oil say hoi to wohi oil gas kay sath condensor ma mojood hay jo dobara choking ki waja ban sakta ..aik or bat conpressor ki pumping make sure karna bht zaroori kay wo sahi hay ..
Ma sha Allah bro mara ac ma ak probum ha mana usa servic keya tha jb wo dubera lagaya ha to ab coling coil mana water droping ka masla ha or ka 4 band garm ha or baki thanda ha bss 4 coil ma gass ni chal ray ha mujha gide kra plz
Mere ac ka b same issue ara tha but koi b techician ka dhyan choking line par nahi gaya muje wo ac change karna pada kash yeh video mai pehle dekh pata mere hazaro rupees bach jate
Sir main mistiri nhi hun or mujhe ac ko kisi Karan se utarna hai.. mujhe gas store karne ke liya tools nhi hai to main detect ac pipe khol sakta hun koyi ag to nhi Lage gi.. plz reply fast.
Whirlpool 1.5 ton ac chokeng problems thi but mene caplarry or filetr dono chenge kr di or mene hatho se hi flush kra pr jb mene gas dali R22 to sir colling nhi aa rhi oR jb mene hatho se pin dabaya gas charhing pin to normal pressur nikl rha suction pipe se kya problem ho sakti h plz air bataye
Sir ma india cy ho pr lekin ma bi electricain hu bt ma app cy bout kush sekhny ku mila thnku so much ji
Mashallah sir G Boht khoob AUR humesha k trah yeh video b zbrdast hy ❤️👍
Nice sir ji bhut ache se samghaya hai aap ne
Masha Allah bohat khoob samjhaya ji Thank's
Bahut accha samjhaya sir apne 👌
Sir kaha se hai aap
Wah. Kya baat agar aapki shop india delhi me hoti to mai aapke sath hi kaam karta.
Zabardast perfect work bhai 👍
Laken hamen kasy pta chaly ga k chocking indoor me he ha.
Or meter ki nidle b ni hill rahi the?
Gas ka pressure chocking me Kam ho jata ha?
Sir, outdoor unit ko flushing nahi krna tha...yeh B toh ho sakta hai k is k caplery b chocking kr raho ho
Bhai us ny just indoor ki chocking thk ki ha
Outdoor ki Chocking next video me
Hahahaha us ka wait kryn 😅
Asalmoalikum Bhai Masha Allah zaberdast video ha Allah AP ko kush the Bhai
Naeem bhai 1 outdoor 2 indoor system bane video upload keren shukria
Naeem bhai aap electronic expension valve ke upar video bnao uska kya kaam ho ta he kis trike se kam karta he our use kese check karte he ye sahi he ya kharab
Dear channel par already video mojood ha, kindly watch it
Bhai fleshing nitrogen se bhi to kr sakte the gas se hi kio ki iske bare me bataiyega.
Pls tell that after flushing how to check the recommended compressor oil level that should be in the system for proper lubrication of compressor parts for prolong life. Pls also tell me that after each gas leakage repair, is it necessary to makeup oil level and how much fresh oil should be added. Thanks
Ooo bhi is ma itna ni hota agar lek zada ho to oil chak kar lo
I have read it somewhere that half liter compressor oil is required in 1.5 ton AC. So in my view if a AC gets 2 to 3 times leak then oil make up become necessary otherwise compressor may get seized.
I'm an engineer and as per my knowledge at least 500ml compressor oil is required in 1.5 ton AC.
@@khawajajodat8763 wud yu also k ow a good tech icia. For hiar hi window 1.5tone who cud want capillary..change filtee inside in Delhi
Mehrauli area nebe reasonable in his charges nd if gas doesnt then can he avoid gaa recharge lime in this vedio ..though they used the cylinder
Capalary flashing nahi karte kya
Pa g tusi great ho azeem loogu k azeem kam
نعیم صاحب دی گریٹ۔ آپ کی ویڈیوز بہت آسان فہم اور ڈیٹیل کیساتھ ہوتی ہیں۔ آپکا جناب نمبر کیا ہے
Aap nitrogen use kar sakte the..
Air pressure sa bhi hojata. Gas kyu zaya ki?
Hello brother I am from India 🙏
Brother aapse request hai ki aap ek video banae capillary data per aur yah bhi bataen window mein aur split mein capillary data mein kya fark hota hai ,
Aur jab bhi aap capillary data ke bare mein bataen to yah bhi bataen capillary single line leni hai ya FIR double line leni hai 🙏
Brother aapse request hai 🙏
Deep freezer 600 litre mai evaporator ki length kitni honi chahie aur condensar mein length kitni honi chahie fit ke hisab se bataiye aur capillary data bhi bataiye
Aur capillary kitni lagani chahie single ya double , aur compressor kaun sa lagana chahiye 🙏
Hi mester shirzad
My job is hvac system can I use of LPG capsoul for flash system
Shukriya Naeem bhai is jankari k liye N2 se bhi kar sakte h
Ek baat btaye mujhe jab aapne Suction line se charging pipe jode to L-key se Suction valve ya discharge valve kholna ya nhi??
Dono ko off hi rakhna hai
Ya kasy pata k indor mai hi choking Han outdoor mai be to ho Sakti Han choking caplari k ander ya filter mai
Gd question
Naeem bhai main mohammad adil india 🇮🇳 se.Naeem bhai window ac ke pure system ko nightrogen se flush kaese karte hai uske upar bhi video bana dijiye bhai plz
bhae jo indoor line me air aa gae uska kia solution hy? purge kerne k bad air b remove kerte outdoor connect kerne se pehle?
❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤❤ mashallah zabardast bhaijaan naeem bhai nera naam bhi shahzad h India Delhi se kese h aap har video aap ki dekhte h ek question tha k aap ne iski gas west kyo nhi ki na outdoor flesh kiya mere Ac m choking huyi thi mene campressor cheng kiya tha but fleshing nhi ki phir dubara sari gas west ki or is tarha se fleshing ki so aap ne kyo fleshing ki campressor cheng kiya tha kiya ya bina cheng k bhi ye problem aajati h and aap ne outdoor kyo nhi fleshing kiya or gas west kyo nhi ki plzzzzzzzzzzzzz reply
Jo gas store ki hay us say bhi yahi process karna zyada behtar nahi tha ? Amount of gas to wohi laga ..my point is kay wo gas is oil ka sath chali hoi thi , fresh gas charge hojati ? ? ? Kiya khayal hay apka ?
Nhi sir, cylinder main gas ka pressure zyada tha, outdoor unit k mukablay main, aur achay say liquid b ban gya, aur achay say fleshing b hogai.
Meri na cheez raey ma is say zyada aham yah hay shayad kay reverse route of gas flow clear everything more then normal flow route of gas .🙏 keep your good work up 👌👌
@@leopardkiteflyingclub5514 thanks janab
Bohat sukriya
Agar filter chok huaa tab?
Asalamwualaikum Neem bhai nitrogen ka istamal bhi ho sak ta tha
I have some questions 1) Discharge valve of oudoor unit was closed while doing flushing?2) Can we do flushing of indoor unit with air by another compressor then attach the discharge pipe and do vaccum by vaccum pump? 3) There is a loss if compressor oil , if not added some oil in compressor will it not damage the compressor?
Good qustion
Gas nkalne k baad oil charge ni krna hota???
Mere pas haier ka dc inverter ac hai...
Kia gas k sath oil bhi charge krna hota hai??
Hi vhai🖐️ I am from Bangladesh ❤️
Outdor kaha se clean hua
Dost Jaruri hai kya aese case me Aaj indor hi chowk ho or outdoor sahi ho,,,kya chowking condition me jab ice luquid line per aa ja rhi thi tab guge miter stable tha ya variable please bataiye
❤❤❤❤❤❤ sir kya aap ne leakage test Kiya tha aap ne nhi kyo ki pressure 20 psi tha
Lekin jo oil pipe se bahir aya hai uski waja se comprossor heat nahi ho gha kya.? ...ya is se koyi farak nai pardta..... Jo oil bahir nikla wo compressor se kam ho gya ..... Kya gass zaya kar k compressor oil poora karna chahiye ya aise hi kaam chal jaye gha .....?
Same question mery mind me hy
Compressor ma oil dalnay ki zarrorat nahi ..zyada behtar tareeqa yah hota kay jo gas thi usi say flush kartay or new gas charge kartay ..choking gar oil say hoi to wohi oil gas kay sath condensor ma mojood hay jo dobara choking ki waja ban sakta ..aik or bat conpressor ki pumping make sure karna bht zaroori kay wo sahi hay ..
Bohot bohot sukria
Sir ji gas ke badle me hum vacum bhi istamal karsakte he kiy please batao Bikram odisha
Gas lock krke indoor or outdoor unit ko vacume kr skte h???
Gas lock krke only indoor or uski piping vaccum ho payegi
Outdoor vaccum k liye outdoor pura khaali chaiye no gas
Agar R410 gas ho to aise hi flash kar sakte hai plz reply
Bhai jab chowking problem thi to aapne gas kese lock kari outdoor me🤔🤔🤔🤔 back pressure to a hi nhi ra hoga
❤
Llyod new inverter ac me vaccum krna zaruri h
Sir iski piping kitni meetar thi or gas kitni lagi isme plz bataye super video from india
10 ft pipe length
Half kg gas used aprox.
Jb ac ki liquid line jodni h to dubara vaccum bhi karna h kaya
Yes
ya kesy confirm kya k oil choking he ha ? capillary be tu chock ho skti ha ??
Ma sha Allah bro mara ac ma ak probum ha mana usa servic keya tha jb wo dubera lagaya ha to ab coling coil mana water droping ka masla ha or ka 4 band garm ha or baki thanda ha bss 4 coil ma gass ni chal ray ha mujha gide kra plz
Mashallah Naeem bhai zabardast
Naeem bhai mera ak sawal hy ap sy agr kisi ac pr nahe likha howa k iss ma kn si gass dalny hy pr humain kisy pta chaly ga k iss ma kn si gass dlly gi
Sir aapne kaise confirm Kiya ki Gaish chok h
فریج کے نیچے کیبنٹ میں جو فریزر کا پلیٹ لگایا جاتا ہے اس کے سائز کے بارے میں ویڈیو بنائیں ۔۔۔۔۔۔۔
Naeem bhai kya mi apki dukan par kam kar sakte hai
Apse Kam sikhne ka moka milta kash 🥰
Use nitrogen gas for flushing the pipe line. Vaccum the unit and gas charge.
Nigegeon and plushing and us last use bai R22..R11.ues and last which gas same use checkup goodflushing ga good vacune and charge solved..
Suction KA wall Band Karke gas dala tha bhai ya khol karke bhai
Assala mu alaikum bhai app ki video bahut dino ke baad aati hai aap jaldi jaldi video dala karo
Wa Alaikum Assalam
Will try
Sir N2 se kr sakate h ky???
Reply me
Oil kam ho gaya iska kya? Naya add on kiya?
Kitnaa bill banaa diya aapne Inka ye bhi to batayein..pyar saa jawaab deejiye saaf saaf
very bad see your safety first it will harm envirment and also your hand
Naeem bhai👍👍
Kya R22 gas se flushing kr skte hi.. environment k liye r22 ka bahr air k sath mixed ho jana sahi hi
R22 me koe problem nhi ati agr bahar ki air mix jo jayegi to
Haa lekin thodi bahut
Outdoor nhi hoga clean ise
Mere ac ka b same issue ara tha but koi b techician ka dhyan choking line par nahi gaya muje wo ac change karna pada kash yeh video mai pehle dekh pata mere hazaro rupees bach jate
Buhat khub jabardast 🎉
Naeem bhai Ac ko on kar k flashing kya jata h kya agr bta den to meherbani hogi
No
Brother ye liqude Kya hota he kindle tel me
System ko vacuum kyon nahin kiya bhai isase bhi problem a sakti hai
Ap ke ladke badiya kam karte hai
Sir guess ki jagah air pressure de sakte hai
Yes
bhi services valve band kr kaa flash karna ha indoor agr chock ho to
Naeem bhai dobara chek karwsna tha
Very good Sir
Sir ji single door refrigerator freezer ki return line se oil Ara hai
Likej he bhai
Nice video Sir 👌👍
Sir aap N2 se flush karte to acha hota R22 Gas ka prise jyada hai
kya rate hai n2 aur r22
R22.404A?????
Bahut hi acha sir.
Very good video Bhai jaan
Sir job to sahi hai magar aap ne N2 (nitrogen) gas se flushing karna or bhi sahi rahta
Package unit ka full wiring ka bare ak video upload koriye
Sir main mistiri nhi hun or mujhe ac ko kisi Karan se utarna hai.. mujhe gas store karne ke liya tools nhi hai to main detect ac pipe khol sakta hun koyi ag to nhi Lage gi.. plz reply fast.
Gas zaya ho jaeygi
Direct kholnay say
@@NaeemTechnicalTV1987 koyi dikat to nhi hogi jise kuch log bol rahen ki aag lag jayega kholne se
@@khanafridi5680 nhi aisa kch nhi hota. But pehlay gas ko waste honay daina. Phr jb gas aana band ho jaey tb khol laina
दोपहर में r32गैस डलवाई तो एंपियर 7 ले रहा था technician के जाने के बाद शाम को नापा तो एंपियर 5 ले रहा था।वो कैसे भाई बता सकते हैं।
Window hota to!!fir gas.Ko kaisey bachaayein
Good information ℹ️
Thank u brother so much for help
very good job
Whirlpool 1.5 ton ac chokeng problems thi but mene caplarry or filetr dono chenge kr di or mene hatho se hi flush kra pr jb mene gas dali R22 to sir colling nhi aa rhi oR jb mene hatho se pin dabaya gas charhing pin to normal pressur nikl rha suction pipe se kya problem ho sakti h plz air bataye
Check indoor unit distributer
Sir kya distributer k karan returning nhi aa rhi jb mene gas dali to back aa rhi thi fr uske bad se returning nhi aa rhi
Condensor GAram hawa v achha nikal rha but thanda nhi kr rha ac or suction me returning v nhi aa rha ppz rply me sir
Raat zyada ho gya tha uslye is complent ko chor kr ana para or discharge pipe pr ice v aa rhi h
Ampere kitne le raha tha ?
Badhiya hai g
assalaamu alaikum Naeem Vai main 3 saal se aisa kar raha hoon lekin kabhee-kabhee ghabara jaata hoon
Kuch help karie mujhe।
Tkanksssssss deear brooooo .❤🤲❤
Return kyaa matlab??
Good information
Choking me kya kya problem hoti hai ye bhi batate chalte to achchha hota
Super sir 👍👍👍👍👌👌👌👌👌💯💯💯💯
Thank you sir❤
Ma Sha Allaah ❤
Very good work
Good job 💯