Compressor Overheating | Split ac Not working | Capillary blockage & Solenoid Valve Issue

Поделиться
HTML-код
  • Опубликовано: 17 ноя 2024

Комментарии • 43

  • @azajahmad6149
    @azajahmad6149 Год назад +1

    Good job
    Bahot kutch aapse sikhne ko milta h

    • @teacheverythings3895
      @teacheverythings3895  Год назад

      Thanks bro
      Waise jis mashin pe kam kiya hun wo mashin avi tak behtrin chal raha hai .mai samjh raha tha ki successful nahi hga but real fault tha ki ak capillary block tha to chal es liye raha tha ki environment ka temperature thoda kam tha but full garmi ka mausam suru hote hi head pressure hight me jaker compressor ko over heat ker de raha tha.

  • @prakashgotame8875
    @prakashgotame8875 Год назад +1

    Aap sir jugad ka maharaja haii sir aap bada technician haii🙏🙏

    • @teacheverythings3895
      @teacheverythings3895  Год назад

      Thanks technician ko adiktar jugad wala kam ana chahiye kyo ki jab apna business ho to kafi fayda hota hai.

  • @pradumsaini1717
    @pradumsaini1717 8 месяцев назад +1

    Bhaiya video dala kijiye aap apke video ka mujhe intjar rahta hai kafi achha aap samjhate hain ❤

    • @teacheverythings3895
      @teacheverythings3895  7 месяцев назад

      Thanks meri kosis rahti hai but mai plumber ,electrical,carpentre etc bhi kam me bsy rahta hu to ac ka video thoda late ho jata hai

  • @imransahil683
    @imransahil683 5 месяцев назад +1

    Nice videos ❤ I'm watching from Malaysia

  • @shabbirahmed5166
    @shabbirahmed5166 10 месяцев назад +1

    zabardast ustad

  • @sdyaseen2622
    @sdyaseen2622 3 месяца назад

    Bhai carrier ka purana wala duct ac h jisme indoor unit mein orifice laga hua h aur outdoor without capillary wala system h,,suction pressure 70 ya 80 dalna padta coolin ke liye,, toh iske ke liye koi jugaad h?? Ya ham capillary ka system laga sktey hain kya?

  • @mahamdulhasan6892
    @mahamdulhasan6892 Год назад +1

    Helpful

  • @prakashgotame8875
    @prakashgotame8875 Год назад +1

    Sir kaise reversing valve check hoga piz bataya

  • @AhmedSyed-k1v
    @AhmedSyed-k1v 8 месяцев назад +1

    Bhai 1 meter dono mila ke ya 1-1 meter ki do capillary dali machine kitne ton ki hai

  • @user-yx7uw4nh8n
    @user-yx7uw4nh8n 9 месяцев назад

    Thanks ❤❤❤❤❤❤❤❤
    ❤❤❤❤❤❤❤❤❤❤❤
    ❤❤❤❤❤❤❤❤❤
    ❤❤❤❤❤❤❤
    ❤❤❤❤❤

  • @farhanmalik896
    @farhanmalik896 3 месяца назад +1

    Agar portable ac ka compressor 20/30 min bad trip kr jata ho to kia problem ho sakti ha capictor ok ha

    • @teacheverythings3895
      @teacheverythings3895  3 месяца назад

      Dekhiye portable ac ka compressor agar trip karne me 20-30 minut leta hai to senser check kijiye ,capacitor thik hai to chek kijiye ki uska OLP , jyda heat to nahi ho raha hai .heat ho raha hoga to OLP change ker dijiye .agar us machine me OLP external laga hoga to.
      Condeser coil ki condition check kijiye ki kya wo dusty hai , agar han to deep clean kijiye yani har point per check karna hoga kahi na kahi fault mil hi jayega

  • @jaanjaan2565
    @jaanjaan2565 4 месяца назад +1

    Sir package unit m high pressur 300 ajata hai split ac ka highr pressur 90 horha guide kriye sir

    • @teacheverythings3895
      @teacheverythings3895  4 месяца назад +1

      Yes split me high side 80-90 ata hai, window me bhi lagbhag same , wahi pkg me 280-300-330 psi , ya ductable ac ho jo 4 ton ka usme bhi 280-290 psi high side show kerta hai.
      Pkg me agar 2 compressor sath ho ya alag alag tab bhi 290-300 psi ata hai.

  • @jaiprakashsharma3960
    @jaiprakashsharma3960 4 месяца назад +1

    Ac m 410 Gas jadaho jaye toh kam kase kare Ac Band kar key ya ranime

  • @Thetrade-zone
    @Thetrade-zone 3 месяца назад +1

    Sir mere pass 1 year ka experience hai. To kya main gulf me aaunga. Interview deke aata wo log jitni sarley lagayenge waha pe jane ke baad thoda bahut kaam kam to kya wo log meri salery cutt karenge plz reply sir, aur kya wo log mujhe helper me bhi daal sakte hai kye please reply bahut pareshan hu sir

    • @teacheverythings3895
      @teacheverythings3895  3 месяца назад

      Dekhiye ye bat sahi hai agar ap ac technician me ate hain .aur jo jo sawal bhi interview me pucha gya hai apne sahi sahi jabab de bhi diya hai to gulf me jane ke bad physicaly test ke sath work test bhi hota hai jo kabhi kabhi practycaly hota hai aur kabhi kabhi question answr hota hai. But app ghabraye na himat se kam le ghabrane se jo kam jante hain wo bhi bhul jayenge . Full confident se kam le. Gulf me ane se pahle thodi bahut youtube pe hi kuch video dekhker sikh sakte hain ki kya kya pucha jata hai. Aur yaha ane ke bad bhi full confident me rahe dar me akar kisi bhi interview ko na face kare. Hamesa exam lene wala technician ka confident aur body activity se hi pahchan jata hai ki work exprience kitna hai.

    • @Thetrade-zone
      @Thetrade-zone 3 месяца назад

      @@teacheverythings3895 thankyou sir ji

  • @asifmalik4361
    @asifmalik4361 Год назад +1

    Bhai ji capillary consi number aur kitni lagai please batay

  • @pijushroy8198
    @pijushroy8198 9 месяцев назад

    Sir capillary kitni fit hona chahiye or capillary kitni mm ki hai

    • @AhmadRaisi-fu2ze
      @AhmadRaisi-fu2ze 4 месяца назад

      Es ka jawab sir nahi dega Kisi Jin se maloom karo

  • @Shriram-6277
    @Shriram-6277 5 месяцев назад +1

    Hlo bhai
    Muje bhut problem aa rahi h
    Yaha ke technician compressor change krne ka bol rhe h
    Confused kar rakah h pura
    Kya kru plz aap bataye reply kre

    • @teacheverythings3895
      @teacheverythings3895  5 месяцев назад

      Un logo ne reason kya bataya compressor change kerne ka? Kya compressor grounding hain? Kya compressor ka terminal dead hai? Kya compressor pumping less hai ? Kya starting time high amp bata raha hai?kya start hi nahi ho raha hai? Ya compressor bar bar garam hoker band ho ja raha hai?esme se hi koi reason hoga tak jaker compressor change kerte hain .
      Unse puchiyega reason kya hai

  • @ejaj4213
    @ejaj4213 5 месяцев назад +1

    Jab forway kharab hoga to back pressure jeyada hoga

  • @amzadcooltech8528
    @amzadcooltech8528 Год назад +1

    👍👍👍👌👌👌👌🇦🇪

  • @ansarimeraj5062
    @ansarimeraj5062 Год назад +1

    Size kya hai length

  • @merajulhasan2279
    @merajulhasan2279 2 месяца назад

    Kitna pasa liya apne is kaam ka

  • @sarafatmallick1309
    @sarafatmallick1309 4 месяца назад +1

    Stainer kaha hai?

  • @حاجیمحمدیوسف
    @حاجیمحمدیوسف 5 месяцев назад +1

    اس کا جو اپ نے ریورسنگ وال تبدیل کیا ہے وہ اپکو نہیں کرنا چاہیے تھا ۔ریورسینگ وال اک کا ٹھیک تھا اپ کو بس سسٹم کو واش کرنا تھا اور کیپلری کو تبدیل کرنا تھا ،اس کے علاوہ اپ نے کمپیریسر سے پائپ اتارنے کے بغیر اپ نے سسٹم کو واش کیا ہے یہ بھی اپ نے غلظ کیا ہے کمپیریسر کا جو ائل ہے وہ بھی باہر اجاتا ہے

  • @NAWAZKHAN19928
    @NAWAZKHAN19928 Год назад +1

    😂