How to adjust generator AVR for proper voltage

Поделиться
HTML-код
  • Опубликовано: 22 дек 2022
  • If your generator is not producing the proper voltage then adjust the AVR.
    Remove the back cover, undo the AVR, start the engine and adjust it until it reaches the proper voltage.
    Make sure the engine is running to the proper RPMs before adjusting.
  • ХоббиХобби

Комментарии • 56

  • @oscarverwey
    @oscarverwey 13 дней назад +1

    Just what i needed the 8kw gen set have a new avr but only does 168v instead of 230/240v 😅

  • @Laserwurks
    @Laserwurks 9 месяцев назад +2

    I set my to 120v under a load I use a table saw for the load. Xp13000 generator. 120 at idling no load but dropped to 117 v loaded. Utility voltage is 125.5 here in Tallahassee.

  • @amarbabu8153
    @amarbabu8153 11 месяцев назад +3

    Thank you

    • @10minutefix
      @10minutefix  11 месяцев назад

      Thank you for watching.

    • @salomebruno7482
      @salomebruno7482 8 месяцев назад

      Can you send video of AVR how to replacement

  • @jasontheodore350
    @jasontheodore350 10 месяцев назад +3

    Do you have a link to buy this. I'm currently have the same problem for my generator

    • @10minutefix
      @10minutefix  10 месяцев назад +1

      Sorry I don’t have a link. There are many different types and the specs are all different. Look for the manufacturer and see if they can find you the original or a replacement.

  • @Boholiving
    @Boholiving Год назад +2

    Thank you! My generator is a pwh 10500 if this method does not work what AVR would you recommend that I buy?

    • @10minutefix
      @10minutefix  Год назад +1

      I would suggest you get the exact one it calls for. Go to a dealer and give them the model #. Not just the watts.

  • @ZvikohChinds-xi8nf
    @ZvikohChinds-xi8nf Год назад +3

    Hie can I use any AVR to any 4 stroke generator ,do they have sizes

    • @10minutefix
      @10minutefix  Год назад +1

      No you shouldn’t just use any. Some will not have enough power and some will have too much for the generator. You should use the correct one.

    • @ZvikohChinds-xi8nf
      @ZvikohChinds-xi8nf Год назад

      thanks, so when I'm buying it I had to tell them the size of a generator , my generator is 7.5 kva

    • @ZvikohChinds-xi8nf
      @ZvikohChinds-xi8nf Год назад

      Petrol

    • @10minutefix
      @10minutefix  Год назад +1

      Give them the model number. That is the best way to get the exact part.

    • @ZvikohChinds-xi8nf
      @ZvikohChinds-xi8nf Год назад

      thank you very much

  • @paridecontini9773
    @paridecontini9773 2 месяца назад

    ¿Cómo variar las rpm de un generador diésel?

  • @ibrahemkadhum1180
    @ibrahemkadhum1180 Месяц назад +1

    Clockwise increases .. counterclockwise decreases.. right?

  • @manjeetbedi26
    @manjeetbedi26 8 месяцев назад

    Sir muje yai cahiye new kaha se milega sir please

  • @najiboaliyi8306
    @najiboaliyi8306 9 месяцев назад

    T10y

  • @samueladitya1729
    @samueladitya1729 Год назад

    Mine just suddenly stopped output power, no voltage on any terminals, the terminal to feed AVR has around 2V, checked the continuity of AVR output headers for the field reads 0 ohm or dead short, so it's faulty AVR?

    • @10minutefix
      @10minutefix  Год назад +2

      I would rule out the stator, rotor and brushes first and if they work then it’s the AVR. I have videos on all three and how to diagnose them.

    • @samueladitya1729
      @samueladitya1729 Год назад

      @@10minutefix May I know the Ohm of the winding that power the AVR? mine is 5kw 1ph generator. this gives me headache. Just changed the AVR, and the old AVR seems got internal short circuit, and I think it messes the aux winding that power the AVR.
      I tested applying 24V to the brushes terminals, and there's power. The new AVR produce around 5V initially, but as it connected to the brushes terminal, it dropped below 1V, so I guess the AVR not getting enough power.

    • @samueladitya1729
      @samueladitya1729 Год назад

      @@10minutefix NVM. I injected the rotor with 24v while the AVR is connected, and it probably charges the AVR, works like magic. Probably because i bought a cheap AVR.

  • @mactone1467
    @mactone1467 Год назад +1

    Thankyou

  • @Guerrero1187
    @Guerrero1187 11 месяцев назад

    If you bump up the engine speed a little and get proper voltage should you adjust avr and bring speed back again or just keep speed a little higher. 1-2 full turns

    • @10minutefix
      @10minutefix  11 месяцев назад

      You should adjust the engine rpm to its proper setting. It’s incorrect to adjust the rpm to get the voltage you want. Rpm first, then adjust the avr.

    • @murraychadwick9362
      @murraychadwick9362 10 месяцев назад

      @@10minutefix I replaced my AVR just a few months ago. Last night was the first time I needed my generator during a storm. My generator only ran for an hour and stopped producing power again. I never adjusted anything on the AVR, I had just replaced it. Did that mess up my new AVR?

    • @10minutefix
      @10minutefix  10 месяцев назад

      Did what mess up your AVR? Not adjusting it or did you adjust it?

    • @mcdonaldsokeke3439
      @mcdonaldsokeke3439 10 месяцев назад +1

      ​@@10minutefix my generator produces power and gives light but can't power an underground pumping machine/sumo. It powers fridges, but the freezer can't freeze water and can't even chill properly. Looking at the stabilizer voltage, it gives proper voltage as it used to when it works perfectly. What do I do?

    • @10minutefix
      @10minutefix  10 месяцев назад +1

      @@mcdonaldsokeke3439 was it working before or has it never been able to power those units? You need to know if it can supply the amps it needs. How many amps does the sump and fridge need and how many can your generator output. That’s the very first thing.

  • @waterfuel
    @waterfuel Год назад

    Is this AVR on the Powermate generator?

    • @10minutefix
      @10minutefix  Год назад

      Honestly I don’t recall but any AVR will usually have an adjustment screw on it. Let me know if you have any questions. I am posting more videos on generators as well.

    • @damiantraianavram6784
      @damiantraianavram6784 Год назад

      ​@@10minutefix ce rol are acel surubel??

    • @treditionalgamer9890
      @treditionalgamer9890 Год назад

      AVR ki testing Kaise hogi

    • @anasrafaqat
      @anasrafaqat Год назад

      @@treditionalgamer9890 bhai carbon bushes pr meter say check karo agr 12 volt's avr ko day raha voh to avr ka issue hai

  • @baladanladiabraham6734
    @baladanladiabraham6734 Год назад +1

    Thanks

  • @ibrahemkadhum1180
    @ibrahemkadhum1180 Месяц назад

    Is that meaning decrease fuel consumption ? Or not .. pls. Answer 😊

    • @10minutefix
      @10minutefix  Месяц назад +1

      It does not affect fuel consumption because this does not increase or decrease rpm.

    • @ibrahemkadhum1180
      @ibrahemkadhum1180 Месяц назад

      @@10minutefix
      Thanks 💐

  • @felicity9499
    @felicity9499 5 месяцев назад

    Can this reduce the frequency?

    • @10minutefix
      @10minutefix  5 месяцев назад +1

      No. The frequency is governed by the rpm’s of the engine. Higher rpm means higher frequency and vice versa. Make sure the engine runs at around 3400-3600 rpm’s.

  • @kobobo3601
    @kobobo3601 Год назад

    Why are you dating?

    • @10minutefix
      @10minutefix  Год назад

      Sorry but I don’t get the question?