Part 1 - S85 battery refurbish - Water ingress BMS_F107 BMS_F123

Поделиться
HTML-код
  • Опубликовано: 22 окт 2024

Комментарии • 15

  • @NEWSonTour
    @NEWSonTour Год назад

    Great 🎉 #DerSasse #NEWSonTour

  • @peteroffpist1621
    @peteroffpist1621 8 месяцев назад +2

    Milwaulkee tools has an oscillating tool and a special blade for opening lids on BEVs much faster safer and easier.

  • @wersuss
    @wersuss Год назад +1

    Hi! How did you repaired Cell voltage sensors? I have 2 faults f107 and w107

  • @TeslaKägi
    @TeslaKägi Год назад +1

    👌👌👌

  • @capitanandy2535
    @capitanandy2535 Год назад

    It's a Dangerous thing works at this voltage???

  • @dmarkovina
    @dmarkovina Год назад

    Somebody had tampered with that bolt before or factory seal has just failed due to age?

    • @evclinic
      @evclinic  Год назад +2

      I think seal failed due age. First time i ever seen it to fail on this spot.

    • @jdrs4214
      @jdrs4214 Год назад +1

      He said someone’s been inside that humongous undercarriage battery pack.

  • @thebrain7693
    @thebrain7693 Год назад

    any info on how to reprogram BMS? i have f123 code on my car as well but on 90D pack

    • @evclinic
      @evclinic  Год назад +1

      Training for Know-how costs 800€

    • @thebrain7693
      @thebrain7693 Год назад

      @@evclinic haha, no thank you. i dried the battery n fault went away. no need to clear or pay anyone :)

    • @evclinic
      @evclinic  Год назад +7

      @@thebrain7693 hahah so not true and complete lie. F123 is latching error. Must be cleared over canbus or toolbox

    • @romanp887
      @romanp887 Год назад

      @@evclinic BMS_f123_SW_Internal_Isolation
      This alert points to a high voltage (HV) battery internal isolation breakdown detected. This condition is concerning and should be should be addressed rapidly and thoroughly.
      Thresholds:
      BMS_a123 will trip if the isolation is below 500 Ohm/Volt or 192 Kohms at 385V and the contactors are open.
      The alert will clear if the isolation goes over 1000 ohm/volt and the contactors are open.
      ...seems like no diag clearing is necessary..

  • @schubeedoo9097
    @schubeedoo9097 Год назад

    Wow! Can this also happen to the 75kWh pack?

    • @evclinic
      @evclinic  Год назад +4

      Actualy no. Only if you damaged umbrela cover on the road or mechanical damage on battery pack