Well explained bhai... Humari comapany me . . seimens ki simovert dc drive h...jo ke 720 kw ko rotate krti h... Please explain what is master slave drive...
Not necessary its internally connected with mains supply.it you want external field supply then thease terminal are need to be connect with supply otherwise they are left unconnected
hi sir Sir please make a video regarding various communications between plc to pc and vice versa with their Advantage and disadvantage for eg RS 232, , RS485, DHRIO, Control net, Profibus, USB TO ppi, Controlnet, Ethernet etc
sorry for late reply. Convertors cause short-duration short circuits at their AC input so called commutation notches. to counter this we use input choke.
Hi Sir Dc motor k field current ok hai but Armature k voltage nahi aa rahe hai drive contactor on kara de rah i hai but motor chal nahi rahi hai... Main Sprint ki SL50 drive use kar raha hoon.... Sir please help kar denge problem kaha se ho rahi hai Thank you
Check power supply card, gate fuses and mains input fuses.all digital input should be healthy like fan feedback ,motor blower feedback,brake open feedback if used, if there is any fault on drive display tell me fault code.
A For Automation sir maine sare fuses check kar liye hai sabhi normal hai motor blower feedback bhi aa rahi hai or koi fault bhi display nahi ho rahi hai
because drive keep regulating the armature voltage as per speed and torque required and keeps field current constant.by varing the armature voltage it is easy to regulate the torque and speed.if we control the speed with armature voltage torque remains constant but if regulate the speed by field current torque drops.
Very good keep it up
sir good work and nice video thanks
thanks for your comment
Nice video
Well explained bhai... Humari comapany me . . seimens ki simovert dc drive h...jo ke 720 kw ko rotate krti h... Please explain what is master slave drive...
ruclips.net/video/_mtBwfcru-Y/видео.html
this video is about master slave please watch it.then we will discuss further
Thanks sir..
Dcs 800 drive me kon kon se cards hote hain aur unka Kya kaam hain
Sir a question. What is FL1 and FL2 on DC drive?
It may be Field 1 and Field 2, What is model number of drive?
you should look into user manual
@@aforautomation it's Parker 512C
Its Field rectifier supply terminals
@@aforautomation thanks sir, do two live wires go in FL1 and FL2 or is it Live and a Neutral. Drawings are not clear.
Not necessary its internally connected with mains supply.it you want external field supply then thease terminal are need to be connect with supply otherwise they are left unconnected
Sir please make videos on cud card of simorega 6RA70 drive.
Videos on DC drive parameter ,communication
Sir, pl. Make a vedio for armature and field tuning
Dear sir, plz describe EEI DC drive of zemco.
hi sir
Sir please make a video regarding various communications between plc to pc and vice versa with their Advantage and disadvantage for eg RS 232, , RS485, DHRIO, Control net, Profibus, USB TO ppi, Controlnet, Ethernet etc
sure. it will take some time but i will make video.
Sir, pl. Make a video on siemens simoreg kc dc drive 825kw
Sir kirloskar DC drive besic fault ke solution ke uper video banaye
sir four quadrant regeneration and DBR selection k baare mai batayie ga
jarur.. thanks
Sir d.c drive programming k opar ak video baneye
Multispan d.c.draiv ke canection batane ki kripa kare
Plz share model number or catalog number of drive
Sir DC 6ra80 ka optimization kaise lete hai
Abb Dc Drive ka poora power Diagram banave sir aur usko poora samjhaye
sure brother keep watching. thanks for your comment.
Need you mo.no
My no.9826687537
IS IT POSSIBLE TO ATTACH THE LOGIC CODE ? HOW DO I CONTROL EXACTLY WHAT SHOULD I PULL OR OPEN THE DC MOTOR CONTACTOR
Sir interlocking k upper ek or videos bnao
sure I will make.. thanks
Sir I want to learn dc drive and ac drive commissiong please guide me
Commissioning process is always written in user manual of VFD read everything carefully and watch maximum videos ,you will become expert one day.
DC drive me line chock ka kyaa kaam hai,sir ye bhi batave
sorry for late reply. Convertors cause short-duration short circuits at their AC input so called commutation notches. to counter this we use input choke.
Sir is drive me motor on hone ke kuch der baad motor ki speed dhire dhire kum hote hote band ho jata hai kya karan hoga
check that start command input is proper and all interlock are working properly
Hi Sir Dc motor k field current ok hai but Armature k voltage nahi aa rahe hai drive contactor on kara de rah i hai but motor chal nahi rahi hai... Main Sprint ki SL50 drive use kar raha hoon.... Sir please help kar denge problem kaha se ho rahi hai
Thank you
Check power supply card, gate fuses and mains input fuses.all digital input should be healthy like fan feedback ,motor blower feedback,brake open feedback if used,
if there is any fault on drive display tell me fault code.
A For Automation sir maine sare fuses check kar liye hai sabhi normal hai motor blower feedback bhi aa rahi hai or koi fault bhi display nahi ho rahi hai
plc se kuch speed reference mil raha hai kya wo check karo,agar potentiometer laga hai to usko change karke dekho.
Armature voltage and current variation with field vtg and curt variation is more why??
because drive keep regulating the armature voltage as per speed and torque required and keeps field current constant.by varing the armature voltage it is easy to regulate the torque and speed.if we control the speed with armature voltage torque remains constant but if regulate the speed by field current torque drops.
A Dc motor arm vot 470 and ext volt 310, 60hz if we apply in input of dc drive arm volt 400 and 310 ext, 50 hz what will happen? please let me know
You have to set Input power frequency in drive parameter, drive measures frequency by itself and it will generate fault if set 50 Hz and apply 60Hz.
Based on Input power frequency the SCR switching time and ramp generation signal is changed
I am also sharing with my friends
Thank you so much Anirudh..☺️
what is R,S,T IS THAT R,Y,B PHASE TERMINAL ????
yes