  • Basic operations and function of the EST3x fire alarm control panel

Комментарии • 36

  • @gourabdhara6884
    @gourabdhara6884 2 года назад +1

    Thanks sir for the detail description. Can u please upload one video regarding it's internal components like Loop cards and it's connection and also about how to program a device in Est 3x.

  • @safetysecuritysolutions8348
    @safetysecuritysolutions8348 3 года назад

    This video is very helpful ,thaks sir

  • @mrpeel3239
    @mrpeel3239 5 месяцев назад

    Very helpful. Is it possible to initiate the DRILL function on a specific floor, as opposed to the entire system?

  • @trevoraldrinmatanjun8624
    @trevoraldrinmatanjun8624 2 года назад

    Like my Hotel System , Staff security and Engineering must known system to work .

  • @smokeGR14
    @smokeGR14 4 года назад +1

    Hmmm ran into this panel today..first time seeing it...how do you disable to keep the fire alarm from going off while testing sprinkler..thanks

    • @pltiabq4534
      @pltiabq4534  4 года назад +1

      You need to know the address of the module monitoring the waterflow. There is no easy way to determine that unless you have good as built drawings.
      If you can locate the address then you go to main menu, disable, device, and enter the address P0x C0x D0xxx and then the password which should be 2222

  • @RadnusTechnology
    @RadnusTechnology 2 года назад

    Hello, thanks for the video. Do you have any information on how we can print hard copy reports of 'troubles'

    • @nubbylovin
      @nubbylovin Год назад

      A printer or computer may be connected to the panel through the RS232 port. It's a bit of a process, but is described in the manual

  • @aspenqwerty3
    @aspenqwerty3 5 лет назад

    I would love to have this panel to my facp collection...haha

  • @safetysecuritysolutions8348
    @safetysecuritysolutions8348 3 года назад +1

    Est3x showing map mismatch loop-1 ,how is rectify this compliant please replay....

  • @GE1Vigilant
    @GE1Vigilant 7 лет назад

    In your next video, would you be able to demonstrate how to use the "control knob" (identified @ 1:28) as a volume control for system horn circuits? Inquiring minds need to know!

    • @ryanhaddad3666
      @ryanhaddad3666 7 лет назад

      Not possible. Horn strobe volume is set at the device. Usually hi-med-low. Speaker strobe volume is set via a wattage tap.

    • @pltiabq4534
      @pltiabq4534  7 лет назад +1

      Ryan is correct, code does not allow for dynamic volume adjustment.

  • @andrs8953
    @andrs8953 6 месяцев назад

    I need to test a building with this panel, how can I disable the indicators devices on this panel?

  • @parvezmohamad2997
    @parvezmohamad2997 Год назад

    If I press acknowledge button will the alarm be silenced

  • @muzammilshah4233
    @muzammilshah4233 3 года назад +1

    how should i trouble shoot data card mismatch trouble in est 3x?plz gv m sm suggestion

  • @sureshreddy9332
    @sureshreddy9332 Год назад

    Does it needs dongle to program

  • @michaela.andrews7608
    @michaela.andrews7608 5 лет назад

    I'm trying to locate a pull station. is there a list I can pull from the system?

  • @reubenindia9892
    @reubenindia9892 3 года назад

    Can you upload Installation video of this panel also smoke connection?

  • @mbind1986
    @mbind1986 2 года назад

    Hi, I'm getting alarm 'unprogrammed device data card2' could you tell what is the exact issue.

  • @venkataramana3501
    @venkataramana3501 4 месяца назад

    When new panel installed that time display showing CPU fault how to rectify the problem

  • @kumaraanurudda9531
    @kumaraanurudda9531 5 лет назад

    Good morning what is the charging voltage 3x panel Siga PPS

  • @haidertweet
    @haidertweet 2 года назад

    I had a problem, there is a BATTERY PROBLEM
    And I couldn’t Acknowledge it !
    Can you help to fix this issue?

  • @eudesguedes2892
    @eudesguedes2892 5 лет назад

    GOOD EVENING, DO YOU KNOW TO REPORT THAT FAILURE IS THAT "Card 01, Wired Lasso?

    • @nubbylovin
      @nubbylovin 5 лет назад

      That does not sound familiar. Are you certain that is the correct language?

    • @pltiabq4534
      @pltiabq4534  5 лет назад

      If the trouble is still present use the center nob to select it, press the nob, select details, and repost the error code displayed. Should look something like this, 01 01 0XXX. I'll try to help you sort it out.

  • @giantgobblin1026
    @giantgobblin1026 4 года назад

    Sir its posible to make device address on the panel? I mean can edit the device location thru panel itself?

    • @balacwb9142
      @balacwb9142 3 года назад

      sir how to do plz explain

  • @bertr8070
    @bertr8070 5 лет назад

    How do you fix a ground fault indicator light that does not work? How to simulate a ground fault?

    • @pltiabq4534
      @pltiabq4534  5 лет назад

      It is not possible to repair a ground fault LED in the field. this requires returning to Edwards. How old is the system?Are you the end user or the installer?To simulate a ground fault, make a jumper and touch between one of your power limited circuits, such as the SLC + and the ground lug inside the cabinet.

  • @hadayatullahdawar7497
    @hadayatullahdawar7497 5 лет назад

    Give me link for programming software for est adwards fire alarm.

  • @raymo799
    @raymo799 5 лет назад

    Kindly support, How to fix 'map fault DataCard1?

  • @bertr8070
    @bertr8070 5 лет назад

    Can alarm history be cleared?

    • @pltiabq4534
      @pltiabq4534  5 лет назад

      Yes, in the programming menu there is an option to reset panel history. I would suggest not doing it however, there can be a lot of valuable information saved in the panel history and not many reasons to clear it.

  • @uniquetech4u578
    @uniquetech4u578 3 года назад

    Sir i want est 3 software key

  • @trevoraldrinmatanjun8624
    @trevoraldrinmatanjun8624 2 года назад

    Beep , beep beep how disable alarm system . How disable alarm system I'm tired press silent mode but alarm keep on beep , beep after few minutes.