  • Confortotal USA Mini Split Install 12000 btu 110v 1 ton Ductless Heating & Cooling
    We originally ordered from ConfortotalUSA.com
    Or you can order from our site to be warrantied directly by us for 2 years.
    minisplitsupplyhouse.com

Комментарии • 73

  • @isaiahwindmeyer5957
    @isaiahwindmeyer5957 3 дня назад +1

    Best video on how to set this up by far! Great work!

  • @jjmonty8090
    @jjmonty8090 2 месяца назад +2

    Good video…love the views of both sides. Easiest video to understand from all I’ve watched. From what I know you aren’t supposed to crank down really tight on the flare fitting because you will crack them. This is true for the vacuum pump too because there is a plastic o ring that gets hyper compressed and ruined if tightened too much.
    Also the coils need to be coiled horizontally as to not allow a build up of oil in the loops.
    Great vid

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  Месяц назад

      Glad it was helpful, the oil trap has been disproved by engineers, I don’t have the link available now but I will look for it. We coil the excess lines vertically with no issues.

    • @jjmonty8090
      @jjmonty8090 Месяц назад

      @@MiniSplitSupplyHouse Awesome! Thanks for the update!

  • @jessevasquez8323
    @jessevasquez8323 4 месяца назад +3

    Awesome video. I talked to Maegan on phone and she walked me through on setting the remote control and converting the Celsius to Fahrenheit in a couple of easy steps she was very professional and I would advice anyone to call their supply house for any questions. Highly Recommendations. Thanks Maegan!

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад +1

      We’re always here to help 🙂

    • @miguelperez3129
      @miguelperez3129 4 дня назад

      I need help with my confortotal 220V power install​@@MiniSplitSupplyHouse

  • @petrobull2560
    @petrobull2560 2 месяца назад +1

    Great video!👍

  • @prepsolar787
    @prepsolar787 5 месяцев назад +1

    awesome i just went and check your store going to order two from you soon

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  4 месяца назад

      Awesome! Thanks for checking us out! We’ll see you soon, we offer Free Delivery when you’re ready and know what you need let us know and we’ll bring it to you!

  • @huntergcarswell
    @huntergcarswell 3 месяца назад +1

    This was amazing

  • @Blammoification
    @Blammoification 4 месяца назад +1

    thank you

  • @franorona9851
    @franorona9851 25 дней назад

    It would be nice if you would do a video on the proper settings on your remote for best economic use and saving on electric bill. Justin enjoyed your video. Now do one on the remote settings. 😊😍😎

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  23 дня назад

      Do not use auto, it is best to run on the mode you desire the fan setting you like. These are minimum seer systems. When you are shopping for efficiency, certified inverter equipment will save you 2x as much as these

  • @redneckpackrat
    @redneckpackrat 2 месяца назад +3

    Excellent video. Thanks. Only one question, for clarification.... did you start the unit BEFORE you released the refrigerant? Wouldn't that build up an awful amount of head pressure in it, or is this a more-sophisticated compressor than the old 1990s dinosaurs using R22 that I've monkeyed with in the past?

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад

      We do make sure they power up before we release the refrigerant into the system, you can call Dustin 480-338-6197 for a better explanation on why we do this 🙂

    • @redneckpackrat
      @redneckpackrat 2 месяца назад +1

      @@MiniSplitSupplyHouse I did just that earlier this evening, and Dustin did an excellent job of describing his process and reasoning for it. I'll be doing it that way when my adapter shows up and I can evacuate the lines and evaporator!
      Sure wish I'd come across this vid before making my purchase, it'd've definitely been made through y'all if at all possible!

  • @MiniSplitSupplyHouse
    @MiniSplitSupplyHouse  2 месяца назад +1

    Hello, this video was made July 2022 we’ve learned a lot since then, pulling a vacuum like this is not a true leak test! We do require our customers follow this step to clear the indoor unit and lines of any air, moisture, potential contaminants that can affect the outdoor unit. You can always reach out if you have additional questions 480-338-6197 Dustin
    573-410-2769 Megan MINI SPLIT SUPPLY ROLLA MISSOURI

  • @caru3257
    @caru3257 2 месяца назад +1

    I washed a mini split coil where the homeowner had run the equipment when a renovation had takennplace. What a nightmare.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад

      We always discourage installing before the space is complete! The horrors we’ve seen from careless installs or people not understanding the equipment the way we’ve dedicated ourselves to is haunting 😥

  • @lawlcats007
    @lawlcats007 10 дней назад +1

    Is there a way to run the electrical all outside with a disconnect box? Or do you have to have a wire falling down from the inside unit and use an outlet? Thanks.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  7 дней назад

      You can extend the power cord and run it out with the linesets into a disconnect

  • @SetitesTechAdventures
    @SetitesTechAdventures 3 месяца назад +1

    So this unit gets power from a plug indoors instead of outdoors? Is that the case for the NG too?

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад

      The Confortotal is indoor only the NG is not like that, it is opposite power at the compressor only via disconnect

  • @fredturner1767
    @fredturner1767 3 месяца назад +2

    Great Video! I am considering installing one of these in an RV. I was trying to see on the video, is it possible to run the lines and drain tube out the side of the head unit instead of the back as long as the drain tube is at an downward angle? I would like to run the lines inside the coach and out through the floor to the compressor which would be mounted on a stand in front of the trailer. The lines would run under the trailer and thus not seen until they come up to the compressor.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад +1

      Yes you can I’m trying to share a picture but it only wants to let me upload a video you’re welcome to text me and I can send you some photos 573-410-2769

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад +1

      These kits come with 12’ lines

  • @eugenebarron692
    @eugenebarron692 25 дней назад

    Just curious why would you fire unit up before releasing the Freon wouldn’t think that would be good on compressor to pump with service valves closed.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  23 дня назад

      It is a procedure we follow, if your unit for some reason would not power on and you had released the refrigerant the system would most likely need to be recharged once the issue was resolved.

  • @ChrisSpencer-mr1he
    @ChrisSpencer-mr1he 2 месяца назад +1

    Thinking about purchasing two of these and wondering what outside temp will it work down to in winter weather and still heat inside? Thanks

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад

      We’ve found they will still produce heat at negative temperatures, they lose their BTU output the colder it gets so we size for the heat load at cold temps not the AC

  • @platinumf2505
    @platinumf2505 4 месяца назад

    I have a confortotal that won’t cool was freezing and another one that blows cool but not cold. Been trying to get the contractor that installed them to come out for months. Would you say it’s probably Freon leak

    • @meganrunyon4498
      @meganrunyon4498 3 месяца назад

      Yes that’s been our experience. 9 times out of 10 it is a Freon leak with the issues you’ve mentioned. what state are you located in?

  • @riddecp.2224
    @riddecp.2224 Месяц назад

    Is this unit powered inside through the header (wall plug)? Sorry, looking for an option where I have a full circuit breaker already.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  Месяц назад

      Yes it is, no exterior power is needed. We have higher efficiency units available that require the disconnect at the outdoor only
      minisplitsupplyhouse.com/collections/ngtrade-mini-splits

  • @ernestwilson5591
    @ernestwilson5591 3 месяца назад

    One thing I missed or it wasn't shown in your video your head unit had a power cord attached? Did you attach that, or did it come with that? Now I am confused, I just bought an Everwell mini split (very similar to the one in your video) and the electrical cover on the condenser has two holes in for power/signal cables, so I was assuming that I had to have an electrician to hook me up some outside power for the condenser unit. It is a 110v system, the handbook that came with it is worthless, that is why I have been watching so many you tube videos. Can someone help with this? Thanks.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  3 месяца назад +1

      Hi Ernest, I’m glad you found us. This unit comes with the power cord from the air handler that’s why people call them “DIY”
      Your Everwell most likely needs power at the compressor - Megan Mini Split Supply 573-410-2769

    • @ernestwilson5591
      @ernestwilson5591 3 месяца назад +1

      @@MiniSplitSupplyHouse Hi Megan, thanks so much for help.

  • @caseymacgill3428
    @caseymacgill3428 2 месяца назад +1

    Do you have a unit that I can plug into the inside outlet that has a longer line set? I would like to do a second floor installation.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад

      Hi Casey all Confortotal come with 12’ Lineset kits, when you need longer lines we recommend getting them from a supply house. The units are Precharged up to 25’ if you plan to go longer it is most likely you’ll need it charged for the added length for optimal performance.

    • @caseymacgill3428
      @caseymacgill3428 2 месяца назад

      @@MiniSplitSupplyHouse Can you recommend a place for me to order a 30 ft line?

  • @kevlar1482
    @kevlar1482 24 дня назад

    Well this sucks. My unit has the flexible drain tube on the opposite side of the lineset. Is that a manufacturing defect? Leaking on the inside like a sunova. Not sure how to even try to fix this now that everything is hooked up. Are there possible two outlets on the drain pan and I can open this up and move the drain hose over to the other side where everything else runs out directly?

    • @kevlar1482
      @kevlar1482 24 дня назад +1

      I figured it out if anyone is interested. Pretty obvious albeit annoying solution. Once I got the cover off I could tell the easiest solution is to just drill a small hole through the other side and route the drain pipe into some pvc mounted to the wall. Easy enough to cut the flex drain tubing and have enough length to make it into the pvc pipe.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  23 дня назад

      There are some models that it comes on the opposite side but we do not offer those models.
      Glad you got a solution, gotta get creative with Confortotal sometimes

    • @kevlar1482
      @kevlar1482 20 дней назад

      @@MiniSplitSupplyHouse Yeah, I'm happy with the unit and I chalk it up to inexperience. It would have been obvious to someone who has installed HVAC stuff before. Your video was extremely helpful by the way.

  • @jtheadturner
    @jtheadturner 2 месяца назад +2

    Do you have any videos on the comfortotal 220v installation?

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад

      We do not the install process is the same for all Confortotal unless you have a F MODEL 24000 those are designed to have outdoor power
      480-388-6197 Dustin for tech support

    • @miguelperez3129
      @miguelperez3129 4 дня назад

      Hey buddy did you ever find out about how to install the 220V outdoor power? I just can't get anybody to do them

    • @miguelperez3129
      @miguelperez3129 4 дня назад

      I need your help

  • @fredrenfro7710
    @fredrenfro7710 Месяц назад

    The entire system, head unit and compressor is powered by the inside 120 V wire?

  • @Bryan.Nguyen
    @Bryan.Nguyen 2 месяца назад +1

    Do you know how many seers is this unit?

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  2 месяца назад

      12/13 SEER All systems imported from Mexico that use indoor power only are low seer systems

  • @tonykeeton6526
    @tonykeeton6526 Месяц назад

    Is there a template for locating the hole positions.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  Месяц назад

      For these there is not that’s why Dustin measures starting at 1:46 in the video

  • @rojeliom2389
    @rojeliom2389 4 месяца назад +1

    Where's the fuse located?

    • @davidhankins5708
      @davidhankins5708 4 месяца назад +1

      No fuse. IT is a 110 volt plug in unit. Inside handler plugs into wall outlet and provides power to outside compressor.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  4 месяца назад

      David is right! If your local codes require a disconnect you can feed the power cord out with the Lineset and wire it that way

  • @johnjackson224
    @johnjackson224 Месяц назад

    Does anyone have that brackets (inside one) dimensions or an install template?

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  Месяц назад

      These kits do not come with an indoor template that’s why we measure to get the accurate placement for the hole

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  Месяц назад

      I (Megan) will see about getting the dimensions for you

  • @crescobar124
    @crescobar124 3 месяца назад

    I have a question... I installed one in my house and I followed all the steps in the manual and the video as well and my compressor only turned on for a few minutes and the fan only turned on when I put it in fan mode. Do you know why is that happening

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  3 месяца назад

      There could be many reasons
      What is the temperature set at, try turning it all the way down in AC mode and letting it run
      If it is at temp it will not think it needs to kick on

  • @sarentopi1502
    @sarentopi1502 Месяц назад

    This is an invalid training video. It doesn't show pressure test prior to vacuum. Sustaining vacuum does not guarantee a tiny leak is not present.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  Месяц назад

      You’re right, we made a comment clarifying that this is not a true leak test, this is a good enough vacuum to clear the lines for us to guarantee your warranty when you shop direct with us 🙂

  • @shitzUnotz
    @shitzUnotz 3 месяца назад

    This 110V confortotal systems is designed to be wired to a quick disconnect outside by the compressor, right? I noticed you used a plug-in cord that looked like it was connected to the head unit. I don't want that I just need to make sure that is not how this system works before I buy it.

    • @MiniSplitSupplyHouse
      @MiniSplitSupplyHouse  3 месяца назад +1

      It is not designed to wire into a disconnect, it’s only power source is that gray extension from the air handler that’s why these are considered “DIY”
      We do offer the style of unit you’re asking about the brand is NG minisplitsupplyhouse.com 5 year warranty direct by us