How does an Isolation Fault occur in a solar system ? // How to Resolve Isolation Fault ?

Поделиться
HTML-код
  • Опубликовано: 7 ноя 2024

Комментарии • 51

  • @mspaksolar2382
    @mspaksolar2382 2 месяца назад

    Very informative

  • @Bilawal-Bhutto
    @Bilawal-Bhutto Год назад +1

    Useful & informative ❤️👍

  • @siddhantsingh4798
    @siddhantsingh4798 2 года назад +1

    Very learning session sir
    We all Always wait for your video

  • @energyshiftsolarservices
    @energyshiftsolarservices 3 месяца назад

    very nice

  • @ajeet.singh800
    @ajeet.singh800 2 года назад +1

    Nice information

  • @DevendraSharma-lc5uj
    @DevendraSharma-lc5uj 10 месяцев назад

    Useful info

  • @anilpednekar7370
    @anilpednekar7370 2 месяца назад

    💯

  • @NoLandMan001
    @NoLandMan001 Год назад +2

    Any english explaination please. What is a root caust and how to recovery?

    • @m0hd_
      @m0hd_ 11 месяцев назад

      Moisture, bad mc4, cutted cables

  • @MuneebAkhtar-ir6ul
    @MuneebAkhtar-ir6ul 8 месяцев назад

    Great boss

  • @subhashghate5323
    @subhashghate5323 11 месяцев назад

    Thank you so much 🙏

  • @surajbk1020
    @surajbk1020 2 года назад +1

    thanks, sir very useful .

  • @minujha8214
    @minujha8214 2 года назад +1

    Nice information sir

  • @AmitKumar-qz2us
    @AmitKumar-qz2us Год назад +2

    Where should be minimum folating voltage of healthy Dc String ....

  • @Videos_editor7864
    @Videos_editor7864 2 года назад +1

    Sir mere samne problem aa rhi iso fault। P to N 360v
    P to E 360v fix
    N to E 0v aa rha hai to kya problem ho sakti hai please suggest

  • @rameshgaurikar8284
    @rameshgaurikar8284 2 года назад +1

    Sir,mere growatt Inverter 6kw me "PV Isolation Low" kya same problem hai kya yahi?

    • @mastersolarenergy
      @mastersolarenergy Год назад

      I same problem.
      Growwat be inverter 5kw. Single phase.

    • @rameshgaurikar8284
      @rameshgaurikar8284 Год назад

      @@mastersolarenergy Solution Given by Growatt 2 me-
      Solution-
      pv isolation low is because of DC side strings isolation issue .,if string connectors are not tighten well & not taped completely then water can ingress into it causing low isolation, so in this case inverter will only show the current low isolation status.
      So plz turn off inverter recrimp all mc4 connectors from series and tape it well to avoid any leakage & make sure all string +ve & -ve to ground vtg decreases gradually then pv iso low can be troubleshoot from root.

    • @solarfacts4242
      @solarfacts4242  Год назад

      There is problem with positive or negative wire of string

  • @shreyaelectrical4961
    @shreyaelectrical4961 2 года назад

    Thank you sir very useful video

  • @vishalunawane6155
    @vishalunawane6155 2 года назад +1

    thanks Sir

  • @ravikumarsharma5404
    @ravikumarsharma5404 2 года назад +1

    Sir if negative wire having isolation fault than i check it it's show 0 and positive wire show full string voltages

    • @solarfacts4242
      @solarfacts4242  2 года назад

      It means there is problem in extended wire

  • @MuhammadUsman-xn7fh
    @MuhammadUsman-xn7fh 2 года назад

    thanks you video. could u pls define, isolation fault or PV abnormal fault is same??

    • @solarfacts4242
      @solarfacts4242  2 года назад +1

      no both are different

    • @MuhammadUsman-xn7fh
      @MuhammadUsman-xn7fh 2 года назад

      fine thanks. so pls upload a video of PV abnormal fault. this fault occure when nay MC4 open or short. pls define how to identify this fault.

  • @siddharthsrinet9022
    @siddharthsrinet9022 2 года назад

    Bhai ek vedio solar optimizer ka bhi vedio dalo plzzz 🙏🙏🙏

  • @AmitKumar-qz2us
    @AmitKumar-qz2us Год назад +1

    What if all string wire in physically good condition but still,found some stable voltage PG/NG ....

  • @sahibjotsinghluthra4389
    @sahibjotsinghluthra4389 2 года назад +1

    hello sir
    mere ko bi yahi problem a rahi ha
    mere system mein 6 string hai
    6 string ki voltage 670 hai
    positve to earth grounding voltage 570 stable
    negative to earth grounding 120 hai
    invertor mein dc inject show kar reha hai
    but i cant understand how to solve the fault

    • @solarfacts4242
      @solarfacts4242  2 года назад

      Jo bhi string me aa raha hai you can find the fault and this fails is in between module

  • @sagarsanap5519
    @sagarsanap5519 2 года назад

    Thanks you brother for amazing video.plz make more such videos.i want to ask you is there any permanent solution for isolation fault. Moisture se isolation na aaye iske liye permanent solution hai kya

    • @solarfacts4242
      @solarfacts4242  2 года назад +2

      you should use best quality of connector and connectors should be properly tight

  • @johandepauw5969
    @johandepauw5969 Год назад

    Can we have English speech please?

  • @zainmoin2457
    @zainmoin2457 3 месяца назад

    Apna no share kar dain

  • @norbertnox6887
    @norbertnox6887 4 месяца назад

    You start in English then switch to Hindi, not good. Stop then also using English title to deceive people to have views
    Not understandable for others

  • @benson7600
    @benson7600 2 года назад

    hanep na yan Hindi ko maintindihan.

  • @ketanagrawal8940
    @ketanagrawal8940 2 года назад +1

    Sir what is your experience of isolation fault on 100 kw inverter of Chinese make inverter like Solis, Huawei and sungrow.
    We have noticed that Solis inverter is completely fail in case of ground fault.
    Do you come across such incident where inverter did not trip against the ground fault and completely failed even after all string voltages are healthy.
    Please give your contact number to discuss this with in details.

    • @solarfacts4242
      @solarfacts4242  2 года назад

      Ground fault protection is very important and I will tell in all Inveter this feature is available
      If this is not available then there is a risk of electric shock to human body