Build out a new evap coil and install Part 1

Поделиться
HTML-код
  • Опубликовано: 7 июн 2021
  • Build up a coil and go over 2 speed evap Fan wiring. Talk about nozzles and txv selection for coils.
    If you would like to buy me a cup of coffee www.paypal.me/norcalrefrigera...
    #refrigeration
  • ХоббиХобби

Комментарии • 96

  • @hookedup9424
    @hookedup9424 Час назад

    Thank you so much. I’m installing one of the systems today and this is giving me such confidence to go into it. It will be my first walk-in cooler install.

  • @goldhammer561
    @goldhammer561 3 года назад +9

    The more I watch the more confidence I get to work on refrigeration equipment. Great content my man.

  • @JStorysuoertech
    @JStorysuoertech 3 года назад +6

    Dave is the the man!!! I thought he went part time on us. Lol, we miss your videos brother, you have no idea how much your helping people in the field. Need more people like yourself, making videos, it really helps when we get one of the messed up jobs, we can't figure out. SUPER TECH BABY!!!!!

  • @dustinthewind5538
    @dustinthewind5538 3 года назад +3

    Love the cardboard tip. Learn something new everyday👌

  • @markcaldwell1245
    @markcaldwell1245 3 года назад +1

    I appreciate the info on slip and the nozzle. Not a refrigeration guy but I have seen those and wondered about them. Great video.

  • @apr9286
    @apr9286 2 года назад

    Gonna be working with a company doing more refrigeration Dave, thanks for another great video as always, your content are educational, fun to watch, has tip of the day, and you teach from old school to new school stuff. Thanks Dave 🤙🤙

  • @hvactrevv23
    @hvactrevv23 3 года назад +1

    That makes life easier awesome job Dave 🤙🏻⚡️🤙🏻⚡️.

  • @catherinelachance2239
    @catherinelachance2239 3 года назад

    Thank you for this. We have been using Trenton Preassembled Evans, which are very convenient. However, they are changing over to electronic TX valves and pile of computer stuff.
    I may start building me own. Liking and saving this one!

  • @jaysonhines1
    @jaysonhines1 3 года назад

    This isbthe second video I've seen of yours Dave. Flippin awesome. Loved you adding the wiring schematics and modes of operation.

  • @johnnygarcia7386
    @johnnygarcia7386 Год назад

    wow. you are such a bad ass. So helpful. I just ran into a Bohn and I was a bit confused with no wiring instructions.

  • @sherwinalvarez7365
    @sherwinalvarez7365 3 года назад

    I like when you do these instructional videos. Most of everyone one that watches are in school or green to the teade. The rest just love refrigeration.

  • @healthyfit6790
    @healthyfit6790 10 месяцев назад

    great explanation of the nozzle

  • @mainormoscoso01
    @mainormoscoso01 5 месяцев назад

    thank you great explanation for an HVAC guy, keep up the good work.

  • @bernardbartell6844
    @bernardbartell6844 3 года назад

    Nice an clean, pretty work bud

  • @2010mistersoftee
    @2010mistersoftee 3 года назад

    Nice work Dave,

  • @eduardoacosta2315
    @eduardoacosta2315 3 года назад

    Thank you ( Dave ) 💯 x 💯 Excellent Videos

  • @kennethlobo4420
    @kennethlobo4420 3 года назад

    Great video! Thanks for the explanation on wiring,and the orifice before theTXV

  • @reyrodriguez1005
    @reyrodriguez1005 3 года назад

    The company I work for isnt technically a refer company, but we have customers that have refer equipment so we take care of it. I’ve become a damn efficient refer tech from watching your videos dude. I take care all things refer now, for the company and I do refer calls on the side. Thanks Dave

    • @NorCal-refrigeration
      @NorCal-refrigeration  3 года назад +1

      Great complement Rey thank you. Passing on knowledge like the old timers did for me is my channels Purpose

  • @FlyEaglesFly19111
    @FlyEaglesFly19111 3 года назад

    Aahhhh..the leaking coil jobber.. that was a quick turnaround. Stay safe and be well brother Dave

  • @stephenbullock-yn3vh
    @stephenbullock-yn3vh Год назад

    That's totally awesome dave great work 👍

  • @jasonjoyner6940
    @jasonjoyner6940 3 года назад

    Thanks for the lesson bro!

  • @frednichols6221
    @frednichols6221 2 года назад

    Thanks for the video man really helpful just on the light saving part sometimes it depends where it is going to be installed like in a walking cooler gotta be on 24/7 and on high speed.blessings🙏

  • @bhutehole
    @bhutehole 3 года назад

    this reminded me of how years ago. How i learned the hard way that solenoids are one way

  • @3amigos99630
    @3amigos99630 3 года назад +2

    As easy as 123! Thank you Dave.

  • @scottk0623
    @scottk0623 3 года назад

    I was told by a Rep years ago that the nozzle “focuses & stabilizes “ the liquid refrigerant flow. I like that plastic cover on that unit. Keep smiling.

  • @dant4802
    @dant4802 3 года назад

    Love your videos Super Dave!
    And I might as well be the first to say it....Nice hiss

  • @IFIXCASTLES
    @IFIXCASTLES 3 года назад

    Good job!

  • @neilvestervictor180
    @neilvestervictor180 3 года назад

    great information hvacr mechanic

  • @ReliableHVACR
    @ReliableHVACR 3 года назад +1

    I just put in a Bohn like that, I got called back. The fan plugs are loose and they just hang, had to strap them. 👍🏽

    • @jakem117
      @jakem117 3 года назад

      Normal Dave allows "Quoters" in this feed?
      Guess that's 2021 for ya lololol
      Just just giving ya unnecessary hate. You're good bro

  • @abdulhvac2395
    @abdulhvac2395 3 года назад

    Thank you for sharing👍

  • @harrydickson4575
    @harrydickson4575 3 года назад

    Excellent video 👍👍👍

  • @jimmyp5487
    @jimmyp5487 3 года назад

    Sweet pretty job brotha 🤘🤘🇺🇸🇺🇸

  • @izaarcondicionado
    @izaarcondicionado 3 года назад

    good job!

  • @impalaflexin420
    @impalaflexin420 6 месяцев назад

    Your video rock man

  • @reynanmegx23
    @reynanmegx23 3 года назад +1

    Pro tip: Home Depot 6in1 screw driver goes in nice and tight in that 1/2 pipe when pushing the nozzle and o-ring in

  • @gregbowman3598
    @gregbowman3598 3 года назад

    Good one Dave 👍

  • @garywilson5192
    @garywilson5192 3 года назад

    Awesome!!

  • @philltafolla
    @philltafolla 3 года назад +2

    Min 20 i tough you had someone looking at you while you were brazing the solenoid valve and expansion valve 😀🤭. Looks good my only concern with those plastic hinged covers are if my clumsy azz would get too happy with the torch and melt it 😂😀

  • @jakem117
    @jakem117 3 года назад +2

    I still think for a medium temp box or reach in. The evaporator fan motors should be energized 24/7 365 at their maximum synchronous speed.
    Forget ECMs for refrigeration. The replacement parts are expensive in comparison to the energy saved. Even some of the fan brackets don't even let you use a PSC or shaded pole... So the customer is the one to suffer especially if it's not in stock. This world is backwards

  • @jamestoy426
    @jamestoy426 3 года назад

    Love my Klein crimpers

  • @deebo_srt1513
    @deebo_srt1513 Год назад

    I know a guy who installed a piston with a TXV on a residential unit and he spend 5 days troubleshooting the system lol

  • @graywolf2694
    @graywolf2694 3 года назад

    I do transportation refrigeration, we had a coil that was slipping apparently, we never have to mess with stuff like that so we had no idea, once the coil was removed we found that the nozzle was loose just rattling around, made the coil ice up

  • @wonderhomie2011
    @wonderhomie2011 3 года назад

    To each there own but I usually get the prebuilt from Trenton/United.

  • @garypoplin4599
    @garypoplin4599 7 месяцев назад

    18:46 - I’m disappointed that we didn’t get to see you twist that TEV up and around into position! D…, D…, D…!

  • @electroimpex8897
    @electroimpex8897 3 года назад

    First. Greets from Germany

  • @akshay1374
    @akshay1374 3 года назад +1

    I'm not of fan of 2 speed for air defrost. I jumper t1 to k on the terminal board to bypass it and get full fan speed.

  • @mikestevenson1819
    @mikestevenson1819 Год назад

    End of the earth 😀

  • @milanlipovic7349
    @milanlipovic7349 3 года назад

    I’m #420 for giving you a 👍I think that deserves a free NorCal hat💪

  • @ia9562
    @ia9562 3 года назад

    🔥🔥🔥

  • @rigakit
    @rigakit Год назад

    I like the switch on the back, so the sticker is right side up while the blower is upside down?

  • @tejonBiker
    @tejonBiker Год назад

    Thanks for the video, I attended two calls, the problem solved, but in both services the evaporators have distributor, the lower part of the distributor make more ice than the upper part, do you think in both evaporators the nozzle is missing and one section of the coil is receiving more refrigerant?

  • @truthfiend6909
    @truthfiend6909 2 года назад

    good stuff man!...but what kind of thermostat do i need to activated the high speed of the blower again?..i replaced an old evap with similar product just has 3 blower fans.....there's 2 evaps for this system so they used just 1 solenoid to feed both evaps and thermostat is on the old evap...i wired 115 V only to T1 and T2 , blower fans run on low speed ,don't know how to field wire to utilize the high speed.....a little help would be appreciated! thanks

  • @octaviocorrales6262
    @octaviocorrales6262 10 месяцев назад

    👍

  • @REFRITEKREFRIGERACION
    @REFRITEKREFRIGERACION 3 года назад

    Yes The first time I wired that fan relay with the solenoid wrong, I said ok I wire them in series. Big mistake, electricity 101, relay coil was getting energized and changing fan speed but magnet on the solenoid was not enough to open.

  • @jkim024
    @jkim024 Год назад

    i just remove the black wire on the relay and run high speed.

  • @jimmyp5487
    @jimmyp5487 3 года назад

    Don’t the nozzle also help with flash gas feeding into distributor??

  • @tanzellluckett5360
    @tanzellluckett5360 Год назад

    Where do you run the other two wires going to the clock?

  • @mohamedmskini7335
    @mohamedmskini7335 3 года назад +1

    Waw

  • @realestateservicessaleshea99
    @realestateservicessaleshea99 3 года назад +1

    Almost looks easy!🤔😃
    🥃🥃🤔🍺🍺🍺🍇🏌
    Stay safe.
    Retired(werk'n) keyboard super tech.
    Wear your safety glasses.

  • @Kirkdrive
    @Kirkdrive 2 года назад

    What heat blocking compound are you using here?

  • @dustinthewind5538
    @dustinthewind5538 3 года назад +1

    Not a fan of those plastic side panels on those evaps now.

  • @raviyadav8743
    @raviyadav8743 2 года назад

    Can you please let me know , we have walk in freezer room there is ice forming on floor ,roof pannel side wall also near Evaporator unit ,
    Door heater is working also air curtain are installed,. No door switch installed,
    Dixcell controller is installed.

  • @notaquitter
    @notaquitter 3 года назад

    So basically what you're saying when it's not, ground any have a call compressor and cold air it goes from 1:10 low speed to 2:20 High

  • @sdsd4284
    @sdsd4284 3 года назад

    Quick thought dave now with that new 2 speed fan would the differential on tstat have to be more to accommodate for the lower fan speed during defrost ?

  • @buielectric
    @buielectric 11 месяцев назад

    I wonder "Air Defrost two speed motor" at 6:50 we can choose either 115v or 230v and are there any changes here. The fans could work both voltages 115v and 230v? and what is the part number of the solenoid? I need help. Thanks

    • @NorCal-refrigeration
      @NorCal-refrigeration  11 месяцев назад

      No the fans are either 115 or 230 depending on which you order.

    • @buielectric
      @buielectric 10 месяцев назад

      @@NorCal-refrigeration Thank you. I understand. One more question is how about the Nozzle. I cannot understand the chart attached. My compressor is R407C, what nozzle I should put in_ L 1/2 or L 3/4 . Thank you in advance.

  • @micahjamestt
    @micahjamestt Год назад

    Would not using the nozzle cause iced up distributor tubes to the point that it turns into a giant block of ice ?? Medium Temp 407A

    • @NorCal-refrigeration
      @NorCal-refrigeration  Год назад +1

      No

    • @micahjamestt
      @micahjamestt Год назад

      @@NorCal-refrigeration well it looks like I've got another problem lol. Thanks for the videos bro 👊🏼!!!

  • @JStorysuoertech
    @JStorysuoertech 3 года назад

    What happened to the super tech symbol. I can't find it . It should be a certificate that you hand out to your RUclipsrs. Great video you just put out. Believe it or not I got stuck on that same coil, because the wiring diagram was ONLY IN CHINESE!!!! DA FUK!!!!

  • @tylerbutcher9948
    @tylerbutcher9948 6 месяцев назад

    Where's part 2?

  • @wechselrichterschaltungen
    @wechselrichterschaltungen 3 года назад

    12:36 Difusor?

  • @andygalindo8978
    @andygalindo8978 3 года назад

    That is why they call you the “MASTER”.

  • @Puffalupagus360
    @Puffalupagus360 3 года назад

    Those coils with the plastic side tanks like that are cheap as heck. 8 out of 10 times you can't even get it mounted without the drain pan getting just all bent up

  • @zack9912000
    @zack9912000 3 года назад

    Those plastic side panels I don't trust

  • @jimmyp5487
    @jimmyp5487 3 года назад

    The blue plastic doors look cheesy and cheap as shit.
    Guess every manufacture gotta go cheap now days with all this free money everyone’s getting the economy is dog shit.

  • @stephwaylonwells3218
    @stephwaylonwells3218 3 года назад

    👍

    • @mrdoc8458
      @mrdoc8458 3 года назад +1

      Thanks for the great info.