fronus infineon reborn pv 5200 and pv 7200 complete 42 settings | pv 5200 setting | pv7200 setting

Поделиться
HTML-код
  • Опубликовано: 15 янв 2025

Комментарии • 47

  • @ShahzadAli-vu4yh
    @ShahzadAli-vu4yh 8 дней назад

    Best information in very easier way
    Thanks

  • @zeeshanqureshi8967
    @zeeshanqureshi8967 4 месяца назад +1

    Very good video. Isi tarha baqi inverters ki settings ki videos banaye. Great work!

  • @shahrokhaslam7812
    @shahrokhaslam7812 3 месяца назад +1

    Ma Sha Allah aap ki video buhat zabardast hai.

  • @muddassarnazir2543
    @muddassarnazir2543 2 месяца назад

    JAZAK ALLAH
    aj tk jitni bhi videos dykhi han apki video sbsy best ha.
    Inthai araam r sakoon sy r detail my smjhaya ha apny.
    ALLAH PAK apky kam my barkat r traqqi ata farmayen.
    Aameen

  • @SajjadAli-t7e7x
    @SajjadAli-t7e7x Месяц назад

    ❤.bhi zabrdst

  • @alphapersonalityy
    @alphapersonalityy 4 месяца назад +1

    Bhai sab kmal or details say btaya kh ayse video abhe tk youtube py upload ne hue but mara ik question hy kh
    1) Acha bhai ik question hy kh rat ko almost 3 bjy battry off ho jate hy to uth k wapda on krne prte agr sham ko on kr do to batry ke jga wapda use krta....
    2)Mara same vide wala inverter hy (fronus pv 7200) 4 batteries attach hain osaka ke 120 Ah 12v wale or 200Ht
    3)Konse setting kroon kh battery ka use bhe max ho wapda tb use ho jb battey bilkul khtm or hr chez automatically ho

    • @TechnicianBhai
      @TechnicianBhai  4 месяца назад

      Shukria...bro
      Ap SBU setting rakhe ess main saving ziada hoti hai or 12 number setting ko thora ziada 47.6v per rakhe ta k ap k battery rat ko band na hon. Sbu mode main din ya rat ko inverter 50watt self consumption battery se kar raha hota hai jis wajha se battery apki 3 bje khali ho jati hai. Battery ka bilkul low voltage per jana un k lie safe nahi hai esa agr ziada dafa ho to jaldi kharab ho jae gi...

    • @alphapersonalityy
      @alphapersonalityy 4 месяца назад

      ​@@TechnicianBhai can i please get your number sir?

  • @rehmankhanyousafzai7694
    @rehmankhanyousafzai7694 6 дней назад

    Bro 3.2 pa bhi koi video bano ❤

    • @TechnicianBhai
      @TechnicianBhai  5 дней назад +1

      Uski setting pv5200 jesi same hai.

    • @rehmankhanyousafzai7694
      @rehmankhanyousafzai7694 5 дней назад

      @TechnicianBhai han taqriban same he h ab Pakistan wala mine use nii kia frunas inverter ab wo kasa h

    • @TechnicianBhai
      @TechnicianBhai  5 дней назад +1

      @@rehmankhanyousafzai7694
      Fronus not recommend

    • @rehmankhanyousafzai7694
      @rehmankhanyousafzai7694 5 дней назад

      @TechnicianBhai Yar mine tu lagya h ur yakeen karo bohat acha Kam Kar Raha mery pory Ghar ka lod Chala Raha h

  • @beautyofquran727
    @beautyofquran727 4 месяца назад

    Bohat achi video bania ap ne brother.
    Brother koi aisi setting fronus pv7200 ki jis se pv maximum hi solar se inverter ke display par ati rahy na ke koi izafi load ko chalany se pv up ho aur load ko off karny par pv pair normal hi show hony lagy display par.
    Kindly reply kijye ga brother.

    • @TechnicianBhai
      @TechnicianBhai  4 месяца назад +1

      Thanks 😊 bro
      G asi koi setting nahi hai pv generation load ki hisab se sb inverter generate karte hain. Agr load kam to pv bhi kam ho jati hai or load barhae to pv bhi barh jati hai

    • @beautyofquran727
      @beautyofquran727 4 месяца назад

      Jazak Allah brother

  • @shahzadaslam6844
    @shahzadaslam6844 2 месяца назад

    Salam.bhai aap ne bhout achi aur detail se video bnai hai. Kafi kuch smaj aa gia hai. Mein ne puchna tha k meray pass pv 7200 laga hua hai aur 4 batteries attach hean AGS sp tall 2500..12 v-210AH.. To mein settings me 5 numbe. 26 aur 29 aur 42 me kia rakhon?? Plz reply

    • @TechnicianBhai
      @TechnicianBhai  2 месяца назад

      Jo tall tubler ki setting btai hain woh rakh lae

  • @alphapersonalityy
    @alphapersonalityy 4 месяца назад +1

    Kmaaaaal

  • @shahrokhaslam7812
    @shahrokhaslam7812 3 месяца назад

    AOA, 38 number ki setting 10 A say ziyada kiun na rakhain?
    Agar ghar ka load her waqat zero ho to 38 number ki setting 20 A ya 22 A ker dain ya nahi?

    • @TechnicianBhai
      @TechnicianBhai  3 месяца назад

      G ziada bhi rakh sakte hain but ziada amp per inverter k kharab hone k chances barh jate hain bcz yeh wale inverter grid feeding k lie bhter nahi hain

  • @Islamicvoice_086
    @Islamicvoice_086 3 месяца назад +2

    Fronous ka inverter na lgana bhi log verna sari zindagi zalil ho jao gy

  • @mhassan2470
    @mhassan2470 2 месяца назад

    Sir hm ny pv 5200 k sath 2 tall tubular batteries attach ki hn ek tx 2500 h ur dosri tx1800 h ur 460 Watts ki 4 penals attach hn batteries ki charging b dn ko sahi show hoti h ur 27v pe ponhanch k cut off ho jati hn.mazeed charging nhi leti beshak snu mode b on ho .setting jo ap bta rhy hn yahi rakhi hn pr batteries backup sahi nhi deti ur batteries pe load b around 150 watt ka chalta h jb k electric nhi hoti ye sirf 5 hours tk hi chalta h ya agr load km ho tu 6 hour tk chalta h agr ap ko waja samj ay tu kindly reply zaroor karen .

    • @TechnicianBhai
      @TechnicianBhai  2 месяца назад

      2no battery same rating ki lagani chaie...
      Dosra ap 05 number setting ko USE per rakhe or 26 number setting 29.6v or 27 number 27v per rakhe.

    • @NeedruleoflawinPakistan
      @NeedruleoflawinPakistan 5 дней назад

      G brother mien yeh system Lagya hoon best setting btaiey ga
      ZEWIC PV 8500
      8 nos plates 585W
      4 nos battery 12V, 210AH
      SP TALL 2500
      Setting
      1 per SBU hay

  • @Crane-ys9li
    @Crane-ys9li 4 месяца назад

    Mujy ek video chahiye pv 3200 ki jis me ap btao k betry kesy wapda sy charge nahi hogi Q k hamari 2 battery hain or wo wapta sy charge hoti ha or ha ko koi waida nahi ho rha bil wesy hi aa rha ha

    • @TechnicianBhai
      @TechnicianBhai  4 месяца назад

      16 number setting oso per rakhe.
      Already pv3200 ki setting ki video channel per majood h

    • @Crane-ys9li
      @Crane-ys9li 4 месяца назад

      @@TechnicianBhai bhai new update jo aya ha pv 3200 us ki video chahiye ap ny purany modal ki video lgai ha

    • @TechnicianBhai
      @TechnicianBhai  4 месяца назад

      @@Crane-ys9li
      Same setting hain new or old 2no ki

  • @unboxing-it
    @unboxing-it 2 месяца назад

    AOA sir, jb hm SUB mode use krty hn to day time me bhi inverter minimum 2 amp wapda sy constant use krta rehta he. iski kya waja he?.

    • @TechnicianBhai
      @TechnicianBhai  2 месяца назад +1

      Nahi eski self consumption 50watt hoti hai. Jab 2amp yeh lae raha hota hai tab Agr ap wapda meter per reading note kare gae to woh count nahi karta. Ess k andar capacitor hote hain woh charge or discharge hote hain ess wajha se clamp meter ghalat reading btata

    • @unboxing-it
      @unboxing-it 2 месяца назад

      @@TechnicianBhai Perfect explanation. Thanx

  • @عمرقریشی-ش3ي
    @عمرقریشی-ش3ي Месяц назад

    Salam bhai mera inverter pv 5200 hai orange wala os mai 26 number wali setting mai 29 se zada volt upar nai jaa rahe

  • @RehanAli-tz1od
    @RehanAli-tz1od 4 месяца назад

    Bhai is mein kitna load dal sakhte hai

    • @TechnicianBhai
      @TechnicianBhai  4 месяца назад

      Pv5200 per 4.2kw or pv7200 per 6.2kw

    • @RehanAli-tz1od
      @RehanAli-tz1od 4 месяца назад

      @@TechnicianBhai bhai ac 1.5 ton inverter chala dega

    • @TechnicianBhai
      @TechnicianBhai  4 месяца назад

      @@RehanAli-tz1od
      Yes Easley

  • @Crane-ys9li
    @Crane-ys9li 4 месяца назад

    PV 3200 ki satting please

  • @alikhan1512
    @alikhan1512 3 месяца назад

    Ye PV 7200 brand k naam hai eski actual generation capacity 5600 se zeyada nahi hai. Doosra ye keh eski grid output 27amp likhi hai jab keh settings mein maximum 22amps hai aur haqeeqat mein ye 18amps se ooper trip kar jata hai. Yahi eskay assal specs hai Baki jo likha hain wo sab bakwas hai.
    Main ne es par Sab formula try keay hain aur aakhir mein tahi nateeja nikla hai. Meray pass Canadian solar k 7000 k panels hain ho main ne es se series parallel mein lagaay hain Jin se eski output minimum 6500 aani chaheay magar ye peak time mein bhe 5600 se ooper nahi jata. Series circuit mein ye inverter 580 walay 9 panels se zeyada support nahi karta quon keh DC volts maximum 500 support karta hai aur wo bhe jab barish waghaira k mosam ho to production kam ho to volts barh jatay hain to ye DC trip kar daita hai aur phir aapko aik panels disconnect karna par jata hai. Bahar haal jo log in baton pe razi hain wo ye khareed sakty hain.

  • @عمرقریشی-ش3ي
    @عمرقریشی-ش3ي Месяц назад

    Jab k battery ki bulk charging 29.2 pe hoti hai is ka kuch hal bata de ye apne whatapp number dede ap