- Mga ka Lodi dahil maraming nag tatanong kung safe po ba mag 2 Main Breaker yan po ang tatalakayin natin ngayon salamt sa panonoud...
#Buddyfroi
#CircuitBreaker
#RubberSocket
#Porcelainsocket
#220v line to line
Paki clik sa Link d2 kung saan natin nabili...salamt
Circuit Breaker...................invle.co/clcwn7h
Music intro By No Copyright Music
Music: Roa - Underwater
Watch: • Roa - Underwater 【Offi...
Stream / Download : fanlink.to/Roa_Underwater
License: roamusic.wixsite.com/roamusic
Music Background By No Copyright Music
1.Innovation Technology background music _ Vlog Music _ Royalty Free Music By Alec Koff.
2.NO COPYRIGHT Explainer Corporate Music Copyright Free Background Music For Tutorials MUSIC4VIDEO.
3.Product background music background music for product videos product video music By Alec Koff.
4.right Music) Technology Future Bass [Future Bass Music] by MOKKA
5.NO COPYRIGHT Infomercial Music _ Promo Music No Copyright by MUSIC4VIDEO.
6.Podcast music no copyright background music for Podcast copyright free By Alec Koff.
7.NO COPYRIGHT Acoustic Guitar Background Music _ Guitar Background Music No Copyright by MUSIC4VIDEO.
Very informative po sir, salamat po, dami kong natutunan.😊
Gud day buddyfroi.ang linaw mo talagang mag explain.madami akong natututunan.Merry Christmas sir
Salamat sir Randolfo and advance Happy new Year..
ayos IDOL completong detalye pa shout out sa next video mo idol from taguig goyena st upper bicutan
Sure...cg dol sa next video pohun....ty
galing mo talaga sir buddy! wala kang katulad, sa mga vlogger na kapareho mo when it comee to electricity,
Salamat sir...God bless 😊
May natutunan na naman po ako sa inyo Sir Buddyfroi...well explained... ang galing mo Sir...season's greetings sa inyo ...pa shoutout naman Sir...Godspeed
Cg po sir Danilo note ko d2..God bless
Sir.God bless po..Ok n ok po ang explaination nyo.. na apply ko po sa work ko sa pag electrical..sir galing nyo po..👍👍👍
Salamat Lods...God bless 😊
Salamat sa bago mo vlog buddyfroi may natutunan Naman ako Happy New Year
Salamat din sir Bemar..likewise and God bless..
magling talaga si sir magpaliwanag actual napakalinaw thanks,
Hehe...ty host
Now lang po ulit dito napasyal ,Buddy.medyo busy kasi. nice sharing ulit.
Ok lang Lods..ty
Good afternoon sir. Sapanibagong tutorial merry Christmas
Same to you sir Dayao and Happy new Year..
Nice sir....gets ko po explain mo hppy holidays/GOD bless sir...
Salamat sir Jay na gets nyo..God bless and Happy new Year..
Salamat sir my natutunan na naman ako.
Hey friend😆🙌
Thank you so much for using a lot of my music this year!!
I always appreciate it.
Big love to you‼️
Thank you too my Friend..Advance happy new Year..
Thanks Buddy Froi. Stay safe with your Family.
Salamat din sir Restituto..God bless and Happy New Year...
thank sir mag iingat palagi safety first 😁 dami ko na natutunan Godbless always sir
Thanks din sir kenneth and More power..
Salamat buddyfroi sa mga tutorials mo dami Ko natutunan. Pa shout out naman sir. Ako Ko po si Joseph Buyoc electrical technician ng Kuwait.
Salamat din sir..cg sa next video natin..ingat po kayo dyan God bless..
Master froi, pd po mag request cable tray offset naman sa sunod mo na video. Tnx!
Salamat master froi naa napud koi bag.ong natun.an nimo. Pa shout out usab sa next nimo nga upload master froi. Happy holiday sa imoha.
Cg Lods note nato diri ug usab..ty
Nice tutorial migo, merry Christmas
Salamat sir Rene ug maayong Pasko pud diha Migo..
Salamat sir saturo mo marami akong natotonan dito God bless po
Salamat din sir and More power...
merry christmass sir and advance happy new year.god bless
Same to you sir Brendo..salmt
Buddyfroi thanks sa info and happy holiday god bless po,
Salamat din sir Arthur and Happy new Year..
Merry Christmas ninyo diha migo ug hapoy new year sad🥰❤️❤️❤️
Same to you Migo ug sa imong Pamilya diha...Happy new Year
boss froi good day po. meron lang po ako lilinawin kung ano po ba magandang paraan sa pag lagay ng another outlet ng split type na aircon na safest way pero puno napo ang main breaker panel ko po sa bahay. ano po ang magandang paraan boss froi para makapag install ng another breaker for ACU for DIY lang po at saan po pwede kumuha ng supply na hinde makokompromiso ang mga line ko sa buong main breaker panel. pano po ako makapag branch ng breaker for ACU. god bless...
Sir buddy Froi merry xmas and happy new year po
Same to you sir Joselito..salmt
Sir buddy thanks happy new year
Thank you too sir Cyan..
Pa shout ko dri. Sa legacy colege of compostela, Davao de oro. Salamat kaayo sir.
Cg sir Allan gilista na diri...salamt pud
buddy froi.. merry christmas and happy new year...
Thanks for the visit..same to you sir Doms..
Sir idol buddyfroi pwede mag demo ka ng Naka plangka na main safety switch box tapos lagyan ng mga branches na 20amp, 20amp,15 Amp na mga breaker
Cg dol idea lang paki clik d2...ty
ruclips.net/video/fOt_bvUo4g8/видео.html
Salamat sa shout out sir..finish jud nku imo video ..salamat sa tutorial sir..pa shout out usab sir..from Qatar.ug mga classmate naku sa ubaldo laya cla c elfred ladonga.,karen maizo, rolly andam..salamat sir. God bless you always..advanced happy new year
Cg sir Joseph note naku diri ug usab..salamt Lods..
@@Buddyfroi23 pasensya jud sir ha..cge kog balik balik..God bless..
ano po b ang equivalent ng 4,7n clamitersa30 amp
@@josephdangalan168 ang ibig sabihin doon ang Main mo sa 30amp ay may 4.7amp na nakapasok at dapat 80% lang ang gamitin mo sa 30amp..kaya 24 - 4.7=19.3amp nalang ang pwede mong gamitin sa 30amp na Breaker...Kaya lang nag 2 Main Breaker tayo kaya 19.3x2=38.6 ang pwede mong gamitin tapos ang wire dyan #10awg na may Ampacity lang na 30amp..ty
Sir very informative po.
Ask ko lang po. Kung #8 ang galing sa service entrance magiging safe naba sya na maging dalawa main breaker mo.
Thanks po. God bless.
Opo sir...ty
happy new year master..bagong kaibigan po..master pede pa demo in actual wiring sa pagkuha ng 230v galing sa 400v..salamat master.
Gud am sir Wenggie wala tayong Available sa 400v hanggang 230v lang tayo Lods..salmt
Paki clik sa Link d2 kung saan natin nabili...salamt
Circuit Breaker...................invle.co/clcwn7h
Master froi pwede design naman ng magnetic contactor para sa two sourch of power.para sa automatic on if the one sourch off ...the other will on automatically...thank you...
Cg sir salamat..
Salamat poh...
hi sir luma pakasi breaker ung may fuse pa nakalagay sa labas 30amp 2p gusto kasana palita ng mga mcb
Bag-ong subscriber nimu sir buddy froi.
Welcome sir..salamt
@@Buddyfroi23 ai, dili busy si sir master buddy froi.
Electrician pud ko sir, pwo d palo tanto hanas sa pag electrical.
Salamat sir sa panghatag ug pagtagad, proud bisaya. Siarganon. Pero nia sa luzon nanimpalad.
Napaka husay at linaw nmn idol
Salamat dol...God bless
Salamat idol SA sharing
Salamat din Lods..
Salamat sir
God bless
Welcome Lods...
Boss proi kung lakihan ko Ang linya ng service drop pari akin ginawa ko #8 wire mag iinit kaya Ang linya ko gdling service drop Pakisagot po Sana as soon as possible Ty po at gud day
Pwedeng-pwede na Lods kung #8....ty
Galing po.
Salamat sir Allan and Happy new Year..
Sir,buddy froi sa amoa dri sa davao,tag duha lang ka linya gikan sa service intrans.unsa ba gyod ang mas safe line line o line to netral. Sa line to line ky murag tulo ka linya man gud isa ana ky ground.karon unda man gyod ang mas maayo.salamat..merry x'mass hppy new year.
Maayong adlaw diha sir Reuben mas safe jud gamiton ang line to line kumpara sa line to Neutral..Sa Line to line 110v to 110v lang kung ma kuryentehan pwede ra makalikay dayun, Pero sa line to Neutral dako kau ang isa ka linya sa Kuryente 300v+ unya kung makuryente ka ikaw ang himo-ong suka sa kuryente kay ikaw ang ground sa isa ka linya busa pwede kang madisgrasya dayon..salamt
Pa request sir, 'Paano mag compute para makuha ang Main Circuit Breaker based on load computation'
Pa shout na pod sir
Gud pm sir Jun basic lang ang pag compute sa Load computation sa Main Breaker eh total mo lang lahat ang watts sa Appliances mo at sa ilaw tapos divide sa 230v yon na ang total load ampere mo sa Main Breaker..cg note ko d2...ty
@@Buddyfroi23 salamat idol💖
Maraming slamat sa mga vedeo mo sir.ask lang po..kung kaya ba ng main breaker 60amp..kaya nya ba kahit may nakakabit sa kanya na 20 breaker sa panel board thanks?
Basta malaki ang wire mo sa Service wire pwede lang...ty
Salamat sir froi!!!
Your welcome sir Loarz..
Shout out Bro
Sure...cg Lods sa latest video....ty
Nice sharing po
Thanks for visiting Mam Divine and Happy new Year..
Master buddy froi pwede request naman kung paano mag gawa ng single line diagram sa isang bahay o commercial building para kung mag request ng connection para sa meralco. Ung single line diagram and computation para ma approvan ng meralco
Cg po sir Ventice note natin..salmt
Bro pwedi ka mg parallel tap sa line side basta Alam mo mg sizing ng cable @ CB
Tama po kayo sir..ty
Salamat sa tip buddyfroi
Salamat din sir Marlon..
Good morning sir buddy froi, ok lang ba ang main breaker ko ay, CB at mag branch ako ng MCB at RCCB at RCBO?? Salamat sa sagot mo sir. Baguhan lang ako sir. Thanks.
Ok lang Lods...😊
Sir, unsay affordable nga brand sa clamp meter imong ma recommend, kana unta naay MIN-MAX. Dili ko electrician, Sir. Nagka interes lang tungod aning sige tan aw ug RUclips. Salamat.
Cg Lods, idea lang paki lantaw lang sa diri sa Link video kung unsaon pag gamit sa clamp meter....ty
ruclips.net/video/P3eqXE_gCok/видео.html
tama idol dapat mag palit ka din ng service wire
👍
Sir Buddy Froi,,maayong adlaw..
Ok lang ba mo add ko og Panel sa 3 pcs tankless Shower heater RCBO 63A og 3pcs MCB 20A ang Main Entrance wire #8.
Kay mo Alarm ang akong Solar Inverter og Over current ako e lain og panel akong S.H. nga tag 3500 sa Solar inverter nga panel.
Salamat.
Pwede mag add ug solar panel Lodz basta taas ug AH imong Battery....ty
BuddyFroi, ask ko lng po kung paano mag palit ng wire service entrance? Mag upgrade po kc ako ng breaker from 30A to 60A residential, need pa po ba ipaalam kay Meralco?
Tama po kayo sir ipag bigay alam nyo talaga para walang Gulo..Para may idea po kayo paki clik d2 salamt...ruclips.net/video/MDj4LKeCdQo/видео.html
SIR Buddy tanong ko sana po...
Halimbawa po ang MAIN PANEL BOARD ko po
60A main
20A A.C.U 1hp
20A A.C.U. 0.75hp
20A C.O 1st floor
20A C.O 2nd floor
15A lightings
Tapos po hiwalay po ang kusina na nakatap sa line side at may panel board at branches na
60A main
30A ref
20A C.O
15A lights
Ang tanong ko po pwede po ba ilipat ko yun 60A na nasa panel boars sa kusina at ilagay sa MAIN PANEL BOARD ko po para maging 1 branch sya ng main...
At kung ililipat ko po yun 60A ng kusina po Papunta sa MAIN PANEL BOARD...
magtataas na po ba ako ng main breaker sa MAIN PANEL BOARD dating 60A po?
Opo sir, palitan nyo nalang ng 80amp sa Main, kayang kaya na yon...ty
Sir p advise po kung ilan amperes dapat gamitin kung 2(15amps for lights) 2(20amps for outlet), 2unit acu(1.5hp/.5hp, waterpump(1hp), 1ref(9cuft) ano po kya amperes pra s main at ska po mts salamat sir
Pwede na dyan sir ang 60amp na Breaker, ganon din ang MTS....ty
Good day sir itatanung ko lang po kung pwedi po bang may kanya kanyang sariling breaker ang ilaw at outlet sa boung bahay..?salamat po.
Yon po ang tama sir dapat may kanya-kanyang Branch ang ilaw at outlet para safe..Para may idea po kayo paki clik d2 salamat...ruclips.net/video/lXoC6pd8bQY/видео.html
Gudday SIR! ask ko lang balak ko bumili WELDING MACHINE pang gamit bahay... kailangan pa ba na naka hiwalay/ meron sariling CIRCUIT breaker or puwede na lang isaksak sa OUTLET? at pangalawa sir na tanong .. ang REF at FREEZER pwede ba magkasama sa Isang BRANCH CB? at anong AMPERE kaya SIR... salamat
1.Dapat may sariling Breaker ang Welding machine para safe gamitin..
2.Pwede lang isama Lods...20amp na Breaker...ty
Sir tanong ko lang po sana kung pwede po ba ako magtap sa service entrance o entrada.bale may sarili syang breaker at magtatap ako ng panibagong breaker para sa aircon ko?safe po kaya ito.salamat po naka follow napo ako.
Pwede lang Lodz basta may kalakihan yong service wire...
Shoutout po Ormoc Leyte..
Cg note ko d2 sir Gary..ty
Nice one dol... pa shawt awt ko baddyfroi... Llewellyn Ala of tagum city davao del norte... lalaki ko sir huh 😅
Sowe sir Liewellyn abi naku girl ba hehe..cg note na diri Lods..ty
@@Buddyfroi23 lods pwede mangayo sa imohang messenger nimo para direct ko maka ask sa imoha? Tnx in advance
ganyan ang setup ng breaker ko sa house since pina extend ko ung house binukod nila ang main breaker.. pero hindi 10AWG ginamit sa mismong service line mas mataba ung wire.. so palagay ko safe naman ganyan setup basta swak ung wire ng service line! dapat inexplain mo din paano maging safe ang ganyan setup
Oo Lods nakalimutan ko palang sabihin, paano maging safe gamitin na ganyang set up..na dapat kung dalawa yong 30amp Main Breaker x2 din ang size ng service wire..salmt
Sir buddyfroi unsay asesment nimus imung power saver nga gigamit, so far unsay review nimu ato sir para naa me idea pud sir kun maayo ba gamiton or dili, salamat sir buddyfroi ...
Mas maayo lang to Lods, gamiton kung sa ref ug aircon kay makatabang to sa starting current sa cg ug spike kay naaman may thermostat ang ref ug Aircon...ty
@@Buddyfroi23 maayo pa imu power saver sir? Dili rato dali maguba mga ingon anang klaseha sir? Kay mamalit sad me ana sir, maayo nlng maka save pud me sa kurente gamay, salamat sir buddyfroi sa info
@@thegoodguys2116 So far so good, gigamit jud naku PAREKOY hangtud karn ang energy saver sa aircon naku gigamit...God bless 😀
Maayong adlaw sir froi, ask lng unta q kng pilay ampacity sa pdx wire?
God bless...
Depende sa size wire sir..Kung #14awg 15amp lang ang ampacity kung #12awg 20amp unya ang #10awg 30amp...ty
Tnx kaau sir froi...
Sir ask kolang po kung pano mag wirings ng first floor to second floor at ask kolang din po kung saan itatap yung main breaker ng forst floor to second floor naguguluhan lang po kasi sko thank you❤ sana mapansin
Mas madali Lodz kung sa 1st floor mo ilagay ang Main Panel Board...tapos sempre may distribution wire ka sa ilaw at outlet patungo sa 1st floor to 2nd floor...ty
Sir Froi ask lang po, sabi nyo po kasi #10 AWG ang gagamitin galing sa servince entrance po, kapag THHN po ang gagamitin anong # po dapat? salamat sa sagot sir Froi
Ganon parin Lods #10awg o kaya 5.5mm2 thhn, pareho lang ang size wire nyan Lods...ty
Sir Froi tanong ko lang, sir fwede bang lagyan nang submeter sa baba nang 30 ampere, tas nasa taas nang dalawang 20 at 15 breaker??? Nakikishare lang kasi kami nang kiryente, gusto ko kasi sir may 2 breaker kami, fwede lang ba yun sir Froi??? SALAMAT GODBLESS
Gud pm sir hindi po pwede na maki attach kayo sa kabilang Meter baka kasi ma over load ang service wire na tinap nyo, naka design lang yon sa 30amp.. Except kung malaki ang service wire na ginagamit sa Service Entrance...ty
Sir, yong nakikita ko sa mga naunang bahay gamit nila breaker noon yong fuse type na dalawa.. tanong ko lang, pwede Po ba palitan ng 30amp breaker yong old na fuse type.
Pwedeng-pwede Lods...cg para makita nyo kung paano palitan ang fuse sa Breaker paki clik sa Link d2....ty
ruclips.net/video/fOt_bvUo4g8/видео.html
sir buddy froi pareho lang ba yan sa nag bridge doon nag tap sa service entrance? matawag ba rin yan na double breaker?
Opo Lods...
Gd pm sir, taga ozamiz ako tanong ko lang safe ba gamiten ang 50amp na main breaker na my branch na 20amp at 15amp, my nakita kc ako sa vedion nyo na 30amp ang main na my 20 at 15amp, kung 50amp na main breaker ang gaminten ok lang ba yon?
Safe na safe na yan Lods....ty
sir, pwede ba #6 awg ang gamitin sa service line tapos 2 main breaker tig 30A bawat isa? ty
Pwedeng-pwede Lodz...kahit #8awg thhn na wire....ty
Idol froi pwede ba pagsamahin ang linya ng aircon at ref? Sana po magawan ng video 😊 salamat idol froi and god bless 🙏😄
Dapat naka separate talaga Lods ang Breaker sa Aircon...cg para makita paki clik d2...ty
ruclips.net/video/kU7JINdHXjw/видео.html
Kung e top na lang po sa no 8 service wire Iyong dalawang 30 amps breaker na main breaker ok kaya sir Iyon? Salamat sir.
Ok lang Lods kung #8 thhn ang wire 😊
Sir gud pm po. Tanong ko lang po. Halimbawa po ay 100 amperahe ang main breaker ko, pwedi po bang gamitin ang #60 awg na wire palabas papuntang linya ng poste?
Hindi po yon sir ang Match sa 100amp na Breaker dapat #4THHN to #2..kasi ang #6THHN hanggang 75amp lang..ty
master froi may tanong lng po ako, fuse box pa rin kc kmi which is 30amp, tas mag da dagdag pa kmi ng 1hp aircon, tanong anong pedeng gawin since d ko nmn pede baguhin ang wirings ng bahay, 30amp po daw pla ung mggng breaker ng ac. lam ko mgging over power ung fuse nmn, ano kya pede nmn gawin, or dyan po sa demo nyo san po ba dapt i tap ung may 500watts na ilaw. thanks sa tulong master!
Ito nalang ang gawin nyo sir para safety mag Branch po kaayo sa ilaw ng 15amp Breaker doon nyo eh tapping ang 500w na ilaw tapos 20amp para sa outlet existing mo sa aircon 15amp Breaker din..ty
pwede poba kami gumagmit ng isang safety circuit breaker 40A para sa dalawang 1.5 horsepower na aircon? or pwede din 30A? sana po mapansin salamat po
Pwede naman Lods...Pero mas safe kung naka hiwalay ang aircon sa bawat Breaker na 20amp....ty
Sir buddyfroi ..ask ko lang paano ba malaman,,o magcheck...ng 110-v sa tester.t.y.
Cg sir subokan mo d2 paki clik ty...ruclips.net/video/vilO89pd29A/видео.html
Sir may isa kasi ako linya ng koryenta walang iba na kabit doon kung di refrigirator at ilaw na 8watts ok ba single breaker na 30watts
Kahit 20amp na Breaker Lods pwede na dyan...
Shout-out kay danilo Dela cruz of sta Rosa laguna
Lodi, kumusta, pwede ba mag branch ng line to neutral 30 amp cb to 1 pair 20 amp cb para sa 1-1 hp water pump at 2-1/2 hp na motor para sa lechon griller. Kaya ba #10 galing sa 30A cb at #14 sa tig 20A cb bali jumper. Salamat
Kaya lang Lods...Pero yong #14 eh #12 nyo yon kasi naka 20amp ang Breaker....ty
@@Buddyfroi23 Salamat sa pagreply. Helpful.
Ask lang sir Buddy Kung 60 amp breaker gagamitin q dapat b #6 Ang gamit q wire
Opo Lods!..lalo na kung marami kayong Appliances...ty
boss pwedi bah gamitin pang service entrance yung #10 gauge sa 60 amps na breaker ,.pang bahay poh. tnx
Naku! Boss hindi pwede yong #10 gauge sa 60amp...dapat #6...cg dagx2 idea paki clik d2...ty
ruclips.net/video/81Stx5YQdBs/видео.html
Sir ask ko lang kasi ung anim na breaker ko puno na, at balak ko maglagay ng aircon, saan ko po pwede itap ung aircon aoutlet ng aircon? pwede po ba un itap sa main breaker na 60amp, at ung outlet po ba ng aircon kailangan pareho sa wire ng 60amp na #8?
Pwede kayong mag existing tapping Lods sa line side ng Main Breaker, kahit #12 awg basta ang Breaker 20amp...ty
Paano po Kong 6AWG Ang ginamit sa service instance dyan sa dalwang tig 30 Amper yan dn mismo Ang set up ng breaker
Kung #6 ang ginamit na wire sa service entrance...Pwedeng-pwede...ty
hello po sir, inquire kulang kung anung size ng wire ang pweding gamitin sa main service kung gagamit po ng tatlung MCB panel na meron main 30amps breaker bawat isang panel. kasi po yung bahay namin hinati hati ang mga kwarto. salamat po.
#6awg or #8awg thhn (optional)...ty
Sir, itatanung kulang din po kung ang AWG at THHN na electrical wire ay pareho? Salamat po.
Good noon sir buddy...ok lang po na mag two branches Ako at 30 amp Ang gamit ko,kahit nka sub meter Ako?
Pwede lang Lods...
Sir Buddy froin, tanong ko lang po gusto kp sana subukang ayusin wiring ng ilaw, safe nakaya mga wires kung off ko breaker?
Opo Lods...basta sa Main Breaker, wag yong Branch para safe...ty
Sir,froi pwede bang kumuha ng supply sa Junction box para sa cb ng refrigerator?Ang main cb ay 30amp.,tapos pwede ba 30amp.din para sa refrigerator?refrigerator
Hindi yon safe Lods...dapat sa Main Breaker kayo kumuha ng supply para sa bagong Breaker sa ref...pwede na ang 20amp na Breaker....ty
Kung hindi ko nalang lagyan ng breaker para sa ref.mag splice nalang akon sa Junction box para sa outlet ng ref.total konti lang ang load ng bahay,tatlong ilaw at dalawang outlet lang ok ba Sir froi?
@@jickribo7555 Kung yan lang Lods...pwede lang....
Good day po sir,
Ask ko lng po kung tama po ba to kung mali po ano dapat gawin,
My tatlo ako aircon tig 1hp meron sila tig iisa na breaker na 30amp, at my isa pa po na .5 hp na isa pang aircon nilagyan sya ng 30 amp na breker. At my water station po ako na my breaker na 30amp at sa jetmatic at ref ay my 30amp din ung pinaka main ko po ay 60amp lng,ang tanong ko ay dpat ba taasan ko ng amp ung main ko at ano po ippalit ko,salamat po sir
Sa tingin ko Lodz...kayang-kaya pa yan sa 60amp na Main Breaker...Para sure tayo paki kunan nyo nalang ng clampmeter sa Main Breaker kung ilan ang total current na nagamit...dapat patakbuhin nyo lahat sabayx2....ty
sir pwede bang mag 2nd Main cb from 30 amp main tapos 60 amp 2nd main cb.. san po itatap.. load or line
Walang sayx2 Lodz ang 60amp kung naka tapping ka sa 30amp...Mag trip parin yan pag umabot na 30amp ang load hehe....ty
Sir my tanong po ako ganito po ung scenario. 14 breaker po need ng bahay namin pero nabili ko 8 branches lng . so dalawa bnili ko naging 16 branches na po total .. pano po ung connection nun para ung dlawang panel board magamit ko po.. greetings from davao po. pls reply asap thank you sir.
Eh Jumper mo Lods ang Line side sa bawat Main Breaker...ty
@@Buddyfroi23 pwede po ba pahinge ng wiring diagram po nun? magiging dlawa ung main breaker ko po ok lang ba? dalawa na kasi panel board ko 8branches each.
Salamat buddy froi..bilis ng response mo.
Hahaha...hindi naman...ty
Kaya dbest pa rin yung 60amp main tas 30 tas 20 tas 15amp..branch circuit
sir froi pwede po bang mag gawa ng breaker ulit sa 30amp para sa aircon? ilan dapat na amp sa bagong breaker para sa saksakan lang ng aircon
Pwede lang sir, kung 1hp lang ang aircon pwede na ang 15amp na Breaker tapos #12 ang wire...ty
Sir safe Po ba Ang 2 main breaker na 60A and secondary 50A ...pls
Safe lang yan Lods, kung nakatapping sa load side..pero kung naka line side, hindi na safe ang wire mo dyan sa Main Line...ty
Sir if yong gamitin na wire is #6 maaapikton pa rin bah kng my 2 main breaker na 30 amps?
Hindi na sir..kasi yon ang tama #6 kung dawalang 30amp na ang Main Breaker..ty
Buddyfroi pano kung gawin kong 8awg ang service wire safe na ba sya?
Yon ang tama Lods....ty
Sir ako may problem din sa wirings namin kasi ang 20amp namin sa lighting #14 lang na wire ginamit tapos yung. Sa 30amp namin na breaker #12 pero yung sa amin namin.. 60amps sakto naman yung wire na number #6 okay lang po ito? O baka hindi ito makapasa sa inspection?
Depende na yan Lods sa MERALCO...kasi hindi naman ganon ka dilikado...ty
Lods good evening. Lods #10 pdx o nomex wire main braker 30 amps ang gawin ko pang linya sa ilaw at oulet # 12 ok lang ba i connect ang #12 sa 30amps salamat Good bless
Ok lang Lods, kung malimit lang ang ilaw at outlet sa Bahay...ty
7 na ilaw 7 oulet ok lang ba salamat lods God bless