Thanks for your explanation. Good day, I have a project to work on. I want to turn on and off an alarm after maybe 1Hr, then turn it off after after the alarm sound for let say 30 seconds. And I want the process to continue automatically like that. What can u suggest.
Dear Mr David, Thanks so kindly for the teaching. But have a question, if I am wiring a Star delta circuit which terminal will star conductor and which terminal will delta conductor on the timer relay?
Great video bud. I have a question for you on the delay. I have a delay relay at work and I’m using it for our ac unit for our dampers with actuators. And right now I’m trying to delay the unit from turning on while the dampers open up and testing from what I have it’s Turing on and after 30 sec the unit turns off and dampers start to close then unit turns on and dampers open. So what I’m trying to figure out is I need the unit to have a 30 sec delay not turn on while the dampers open and then have the ac unit turn on around 30 sec
Hello Mr. I have a question on changeover switch. Where do we get control power from to activate the cct at the moment the main power fails and now we want the genset power to come in.Bearing in mind mains power is off and the genset has not yet started.
An ATS has two different circuits, the Main and generator circuit. We use the Mains relay to start and stop the generator, once the generator starts it will power it's own circuit. The only logic is to start and stop the generator, making Mains circuit priority once Mains restores and interlocking both circuits electrically.
Each country or region have got there own voltages Most countries that were colonized by Britain 3phase is 415 and single phase 240, America 3phase 240 single 120 But normally in 3phase system line to line voltage will be higher than line to neutral voltage.
I want to combine switching bathroom lights with the toilet extraction fan. But I want the toilet extraction fan to delay for 5 mins after switching off lights. I have my control and mains power. I'm also using GIC signal off delay timer. Kindly help me out on how to connect the timer and how to set the time of delay. Thank you
Thank you so much man!
I have been looking all over what are A1, A2, A#, 15, 16 and you explained it very well. Cheers!!!
Dear Mr. David,
Thank You Very Much, Sir.
Kind Regards
From, Karachi, Pakistan
Thanks for your explanation.
Good day, I have a project to work on.
I want to turn on and off an alarm after maybe 1Hr, then turn it off after after the alarm sound for let say 30 seconds.
And I want the process to continue automatically like that.
What can u suggest.
cyclic timer can help here.
hello Mr David. what is the recommended Amp of a Change over switch between the 32Amp and 63Amp for a single phase house whose line needs a generator?
Dear Mr David,
Thanks so kindly for the teaching. But have a question, if I am wiring a Star delta circuit which terminal will star conductor and which terminal will delta conductor on the timer relay?
So beautiful explanation...❤
Thanks for you understand I'm from West Africa mali
Great video bud. I have a question for you on the delay. I have a delay relay at work and I’m using it for our ac unit for our dampers with actuators. And right now I’m trying to delay the unit from turning on while the dampers open up and testing from what I have it’s Turing on and after 30 sec the unit turns off and dampers start to close then unit turns on and dampers open. So what I’m trying to figure out is I need the unit to have a 30 sec delay not turn on while the dampers open and then have the ac unit turn on around 30 sec
You can use a cycle timer like IMO TDMD-X, It can delay the circuit for 30 sec and run for 30 sec
Thanks for watching
Our black gold , keep it up
Good instructor
Thanks sir
Pls how do I connect my phase failure sequence to my automatic change over switch using 2 contactor
Hello Mr. I have a question on changeover switch. Where do we get control power from to activate the cct at the moment the main power fails and now we want the genset power to come in.Bearing in mind mains power is off and the genset has not yet started.
An ATS has two different circuits, the Main and generator circuit.
We use the Mains relay to start and stop the generator, once the generator starts it will power it's own circuit. The only logic is to start and stop the generator, making Mains circuit priority once Mains restores and interlocking both circuits electrically.
Thanks,,and do have videos on VFDs and soft starters
Eng david am kindly asking for a difference of 3phase 415 and 380 voltage ratings
Each country or region have got there own voltages
Most countries that were colonized by Britain 3phase is 415 and single phase 240, America 3phase 240 single 120
But normally in 3phase system line to line voltage will be higher than line to neutral voltage.
Thanks sir.Good work
Thanks sir, Congratulations
Pliz can you put your no so that those who want to resch you can do so,we are glad for your tutorial lesson
I will have my whatsapp number in descripotion of upcomming videos.
Thanks ever so much!
How can I contact you sir?. I have an issue with the off delay that I'm unable to crack. Please help
Were is the challenge?
I want to combine switching bathroom lights with the toilet extraction fan. But I want the toilet extraction fan to delay for 5 mins after switching off lights. I have my control and mains power. I'm also using GIC signal off delay timer. Kindly help me out on how to connect the timer and how to set the time of delay. Thank you
If you want 24v you loop from A1 to A3??
thenks broo
Great 1 bro
Super super thankyou sir
how to connet three sources as solar , generator ,and line pwoer by use contactor can you help broo
Congratulations
i need same time on daliy and off daliy start motor on daliy strart motor 2 sec and off daliy 2 sec but one device can work
Hero
Great