Hello, I have a problem getting conntected to my simovert masterdrive. What should I configure in the drive in order to get connected via Drivemonitor? Do I connect via X103? What is the correct wiring of the communication cable? I have the drive in the laboratory and not in the machine. And finally I would like to change the firmaware fo the drive. What is the correct procedure? I do appreciate your kind help. Peter
You can connect using the Front Panel/ Keypad. For cable and connection check this link engrsajidrehman.net/tutorials/master-drive-parameters also given in video description. If you want to change Firmware just because of connectivity issue then avoid it and follow the correct procedure. To change the Firmware, you have to check the current version e.g. 1.x or 2.x and then you can only upgrade the firmware to the same series like 1.1 to 1.2, etc. but can't 1.x to 2.x also it's not recommended to change firmware unless you must have to change.. Hope it was helpful
What si the mame of software did you use ? And please You can share the pin configuration of db9 conector for get online connection thanks and great vídeo !
Hello sir hope u r fine, i wanna ask u how to configure MasterDrive MC Plus (6ES7021) attached Encoder card Model 6se-7090-0xx84-0fe0 with Motor Encoder Sick SRM50-HZA0-S05 Absolute Encoder. I tried making new Application every thing is ok for a while but when i start the control it said PreCharging Fault any idea on this?? Help is greatly Appriciated.
Sorry for late reply... Its mentioned in Siemens Master Drive Manual. This one is already tested and you can get the picture from my website link given in description.
Thank you very much for this video. It was very helpful. Can this be done while the drives are online with the network and controlling motors? I mean, can you pull parameters from the drive while a plant is running?
Yes as we can use the same tool for troubleshooting, but this is not strongly recommended as the time when you will try to configure the drive, it will STOP for a while and a major accident or damage could happen. So I suggest never try to parameterize a drive or any device while Running within the process.
Sorry for the late reply. We can't copy 420 to 430. We can note down the difference b/w default or factory setting of the drive and then parameterize the other drive accordingly.
Hello sir can i ask about master drive.how can comunication between inverter and plc s7 cpu 300 by profibus cable
can we use mpi cable for master drive? because i don't have com port in my laptop.
You can use USB to Serial converter for communication link. To use MPI, you have to use additional adopter
Can you have simodrive software for pc
We can use the same software... Drive Monitor
Can we use simple RS 232 cable to connect PC with drive ?
Verify the connections if it's same then you can as I didn't try that yet
How to online new master drive with drive monitor. I try many time butt no success?
Hello, I have a problem getting conntected to my simovert masterdrive. What should I configure in the drive in order to get connected via Drivemonitor?
Do I connect via X103?
What is the correct wiring of the communication cable?
I have the drive in the laboratory and not in the machine.
And finally I would like to change the firmaware fo the drive. What is the correct procedure?
I do appreciate your kind help. Peter
You can connect using the Front Panel/ Keypad.
For cable and connection check this link
engrsajidrehman.net/tutorials/master-drive-parameters
also given in video description.
If you want to change Firmware just because of connectivity issue then avoid it and follow the correct procedure.
To change the Firmware, you have to check the current version e.g. 1.x or 2.x and then you can only upgrade the firmware to the same series like 1.1 to 1.2, etc. but can't 1.x to 2.x also it's not recommended to change firmware unless you must have to change..
Hope it was helpful
Brother i can ask u question pls tell me how to control speed variation of motor pls tell me
We use simovert drive
Brother how we can encoder bypass in simovert drive or tell me parameter pls tell me
Sir I want to download siemens drive monitor for Micromaster 440
Which site from I get this software
engrsajidrehman.net website given in link..
@@esrtechnologix sir link not opening
What si the mame of software did you use ? And please You can share the pin configuration of db9 conector for get online connection thanks and great vídeo !
great job guys thank You for sharing , God bless you
you are welcome
Hello Sir, which cable config do you used? and what is the comm ports and settings you used? TIA
Complete details are given in website link given in video description. Plz check
Hello can i ask about master drive. Which type cable should i use for comunication between inverter and pc
Cable or adapter
Link for details information is updated in description while you can check this also
engrsajidrehman.net/tutorials/master-drive-parameters
@@esrtechnologix Thank you.
Hello sir hope u r fine, i wanna ask u how to configure MasterDrive MC Plus (6ES7021) attached Encoder card Model 6se-7090-0xx84-0fe0 with Motor Encoder Sick SRM50-HZA0-S05 Absolute Encoder. I tried making new Application every thing is ok for a while but when i start the control it said PreCharging Fault any idea on this?? Help is greatly Appriciated.
Try to run the drive alone first then gradually add the other devices. By this method you will find the fault and reason for that. Hope this will help
Jazak allah khairan bro, very nice and helpful video brother,
Thanks Brother
very good,,
thank´s...
I have a cuestion.. ¿ Can I to work the engine from MonDrive through the driveSimoreg?
Thanks.
sorry for late reply.
You question is not clear. Please elaborate the query.
Where did you get the pin diagram of the cable from?
Sorry for late reply... Its mentioned in Siemens Master Drive Manual. This one is already tested and you can get the picture from my website link given in description.
Thank you very much for this video. It was very helpful.
Can this be done while the drives are online with the network and controlling motors?
I mean, can you pull parameters from the drive while a plant is running?
Yes as we can use the same tool for troubleshooting, but this is not strongly recommended as the time when you will try to configure the drive, it will STOP for a while and a major accident or damage could happen. So I suggest never try to parameterize a drive or any device while Running within the process.
hello sir, thank you very much for this great channel i can't open the website and download, please can you help us to get the softwares?
Sorry for inconvenience, website and all links are updated now.
How to find drive version?
Select USS upload method and after uploading a parameters from Drive you can check the version of Drive and installed Control Card on it.
AOA,
I hope u r very well.
How to copy parameter micromaster420 to micromaster430 via drive monitor?
Regards
Liaqat Ali
Sorry for the late reply. We can't copy 420 to 430. We can note down the difference b/w default or factory setting of the drive and then parameterize the other drive accordingly.
Hi, I like your video
Thanks
Good job sajid
Thanks bro
ESR Technologix where are you from
Pakistan
شكرا لك اخي على المجهود
hello sir can i ask you some question about the driver and the application that you use it for please re comment or give me your contact
Sure you can ask..
i am really appreciate
Thanks you are Welcome
nice
eng ahmed
van
Wtf is with this video quality, is too shaky !
It was made with Mobile of normal camera quality.