PLC to Drive communication using Simatic manager software l Simatic manager l Siemens

Поделиться
HTML-код
  • Опубликовано: 10 сен 2017
  • In this video i show you how to communication process configure between PLC 300 series and G120 series drive using profinet protocol in Simatic Manager software.

Комментарии • 31

  • @majidkhoini6037
    @majidkhoini6037 4 месяца назад

    perfect my bro

  • @priyadarsanbarad1090
    @priyadarsanbarad1090 3 года назад

    very good explanation .thank u for this video.

  • @athilaldurry5880
    @athilaldurry5880 4 года назад

    Many thanks for this information wonderful

  • @rashiagarwal5284
    @rashiagarwal5284 6 лет назад

    Awesome.... This video helps me a lot, thank you...

  • @niryashk9197
    @niryashk9197 4 года назад

    Amazingly explained

  • @sangamkumarkushwaha6509
    @sangamkumarkushwaha6509 Год назад

    Nice Explain thanks

  • @sinnasamy3681
    @sinnasamy3681 5 лет назад

    Super explain very good

  • @sharifhossain8830
    @sharifhossain8830 2 года назад

    ধন্যবাদ

  • @HalaTimor
    @HalaTimor 11 месяцев назад

    I work with siemen and g120 I produce everyday..the new model driver is G115, I can build from casting to complete product😀😀

  • @AnilYadav-wp6gs
    @AnilYadav-wp6gs 11 месяцев назад +1

    sir voice is too low please speak loudly ....so that all can understand clearly

  • @angelodipietro5782
    @angelodipietro5782 4 года назад

    Hello, the output variable for set frequenzy regulation of the driver is floating point or word type? If is word the driver accepts for example 35.7 Hz and motor running at this value?

  • @amarendrakumar3915
    @amarendrakumar3915 4 года назад

    Can you Please share a video lecture on pointers in step 7.

  • @mohammadalhamali7321
    @mohammadalhamali7321 4 года назад

    thanks for your explain but
    kinldy can you explain from where you take wQ50 FOR RUN WQ52 FOR SPEED
    THANKS

  • @yuvanikiduniya4639
    @yuvanikiduniya4639 Год назад

    can u suggest for update or any other issue

  • @vorapobautomation9760
    @vorapobautomation9760 6 лет назад +1

    How about S120 with S7-300 Can you show please ?

  • @yuvanikiduniya4639
    @yuvanikiduniya4639 Год назад

    hello, we have no any option of drive add in smatic manager. my version v5.6

  • @Fadu4u
    @Fadu4u 6 лет назад

    Hello, I need help with connecting siemens smart S700 IE V3 with PC.

  • @thippesh_trpani6584
    @thippesh_trpani6584 5 месяцев назад

    Explain for profibus

  • @satya1027
    @satya1027 2 года назад

    Incase of fixed frequency how the program to be written ???

  • @anshumatiamte8024
    @anshumatiamte8024 3 года назад

    Hello sir, can I get the online training?

  • @suriyat8773
    @suriyat8773 2 года назад

    How to CP343-1lean with G120 thank you

  • @mirzakamil1
    @mirzakamil1 4 года назад

    please send sinamic driv libray file and other plc drive communication with special block.

  • @philippegosset4914
    @philippegosset4914 4 года назад

    You say PLC 300 but your sample is about PLC 1214 ?

  • @innovex4u298
    @innovex4u298 4 года назад

    How the drive know motor data ..your not setting motor data

    • @satya1027
      @satya1027 2 года назад

      We expecting that that's already set in drive