Siemens Step 7 CPU to CPU by Communication via Profibus in Simatic Manager

Поделиться
HTML-код
  • Опубликовано: 13 дек 2024
  • Please Subscribe to Easy PLC Training Sessions for more Videos and Trainings
    Siemens Step 7 CPU to CPU by Communication via Profibus in Simatic Manager

Комментарии • 30

  • @Bear_Le
    @Bear_Le 4 года назад

    Thanks you about video. Its very useful for me.

  • @prabirbasak9161
    @prabirbasak9161 2 года назад

    Excellent

  • @tarekmohsen7572
    @tarekmohsen7572 2 года назад

    Thank you very much

  • @mohalababdelgadir9320
    @mohalababdelgadir9320 4 года назад

    nice , formative content
    please make video about communication via ethernet
    Thank you

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  4 года назад +1

      Sure bro .... but problem is I have only one S71200 CPU with me any way i will try

    • @mohalababdelgadir9320
      @mohalababdelgadir9320 4 года назад

      @@EASYPLCTRAINING i appreciate your reply
      If you can do it just by simulator that will be helpfull

    • @sumankantidas262
      @sumankantidas262 4 года назад

      @@EASYPLCTRAINING bro you just hsow the software work by simulation in the plc sim or by showing the var table.also please try to establish the communication by programming get/put fb with description. so that it will more helpful to understand every step. thanks in advance

    • @sumankantidas262
      @sumankantidas262 4 года назад

      When i have established a communication between two cpu data is not transferring between cpu.when open ob1 shows a message block can nit be monitored because doesnt match what can be the reason.hardware setup os ok

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  4 года назад

      ruclips.net/video/VJbKsYGB5sE/видео.html

  • @firashamdan4175
    @firashamdan4175 2 года назад +1

    very well

  • @aouartamohammed2534
    @aouartamohammed2534 4 года назад

    thank you friend thank you

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  4 года назад

      ruclips.net/video/VJbKsYGB5sE/видео.html

  • @naefyaseen
    @naefyaseen 3 года назад

    first I want to thank you for this great work.
    but I have a question
    In the master Cpu there be a SF . the red led was ON.
    how did the program work?
    you can see this in the end of the videos

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  3 года назад +2

      Yes, correct .......... It was because I power OFF one CPU

  • @listrikinti3720
    @listrikinti3720 Год назад

    I want to make a temporary conclusion, that the communication goes through the exchange of data sent to a word memory variable (MWxx), both PLC nodes can read the word memory status, for example:
    I0.1 on the master wants to turn on the Q0.1 output on the slave
    The master must send a value to the memory word variable when the I0.1 state is on or off, and the slave can read the same memory word state then interpret its value in the slave.
    masters
    I0.1--->Mw100
    slave Mw100 --- Q0.1
    is that so?
    I am not very clear what OB82 and OB121 mean, but I suspect that is where their data exchange is which is used together as a memory buffer.
    is that so?🙏🙏

  • @sumankantidas262
    @sumankantidas262 4 года назад

    Thanks a lot for sharing this type of video on request.please also share cpu to cpu communication by ethernet.it is also necessary for us

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  4 года назад +1

      I will share soon

    • @sumankantidas262
      @sumankantidas262 4 года назад

      Thanks a lot.please share more and more video tutorial for different use

  • @mohamedabdelkaderahmed2709
    @mohamedabdelkaderahmed2709 4 года назад

    I really would like to thank you for all your videos, I really appreciate too much & I hope really you continue to learn more from you because your way in explanation is easy & awsome, in this video I've made all your steps in Simatic S7v5.5 & simulate with PLCSIM but Unfortunately it didn't work however I tried so many times,,,,could you tell me the reason

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  4 года назад

      I think It works with physical system .... not with PLCSIM.....

  • @sumankantidas262
    @sumankantidas262 4 года назад

    Sir it would be also helpful if you show the communication process by programming get/put function.please try to do it in next video with profinet communication

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  4 года назад +1

      ruclips.net/video/VJbKsYGB5sE/видео.html

  • @henriquetecnologias4151
    @henriquetecnologias4151 2 года назад

    Topppp

  • @umarafzal4926
    @umarafzal4926 4 года назад

    Bro how i can communicate with Siemens Extension module ET200 (IM 153-1) . Please make a video on it.?

  • @sumankantidas262
    @sumankantidas262 4 года назад

    I have tried by myself to communicate two cpu by following your this video but the data is not transmitting from one cpu to other.what can be the reason please help

    • @mohamedabdelkaderahmed2709
      @mohamedabdelkaderahmed2709 4 года назад +1

      I've tried as well as you but also didn't work, however,I repeated many times,,,,I think the reason maybe this can work only with Physical system not using PLCSIM as I did,,,Maybe

    • @EASYPLCTRAINING
      @EASYPLCTRAINING  4 года назад +1

      Yes dear you are right .... I also tried with PLCSIM but not working ... I will try with PLCSIM advanced and see the results

    • @mohamedabdelkaderahmed2709
      @mohamedabdelkaderahmed2709 4 года назад

      @@EASYPLCTRAINING Will be waiting for your results ASAP,,,thanks for you really for your efforts

    • @engineerarsalan1832
      @engineerarsalan1832 2 года назад

      @@EASYPLCTRAINING Nadeem sb still waiting for your reply.