How To Install a 30 amp Dryer Circuit With Breaker and Outlet

Поделиться
HTML-код
  • Опубликовано: 28 сен 2024

Комментарии • 123

  • @RBG-tr9ce
    @RBG-tr9ce 6 месяцев назад +5

    I'm doing this exact job tomorrow AFTER I fish the wire down the walls. I had done this 50 years ago so this was a good refresher. "See one, do one , teach one".

  • @davidparker2173
    @davidparker2173 Год назад +28

    You make me feel like an apprentice on the job with a friendly pro who is not dedicated to ruining my day. You also detail fairly well. I would rather hear things again and again than for some guy to assume I already know this, and this, and that. I just hit the like, and subscribe. Thanks

  • @davesillik
    @davesillik 8 месяцев назад +3

    Thank you. Haven't ever done 220 but it all worked out beautifully and safe.

    • @Askmediy
      @Askmediy  8 месяцев назад

      Awesome glad to hear it

  • @MarineMT-0312
    @MarineMT-0312 5 месяцев назад +1

    Brother from the northeast best friggen video hands down no elaborate BS straight to the point, you are the man!!!

    • @Askmediy
      @Askmediy  5 месяцев назад

      Thanks buddy, yeah who has time for BS

  • @botsman35
    @botsman35 Месяц назад

    Absolutely love your ability to turn any project into exiting show!

  • @FrankBocker
    @FrankBocker Год назад +2

    I really like all the little side details and prerequisite information peppered in this tutorial. There's a lot of higher-budget stuff around that's not nearly as informative.

    • @Askmediy
      @Askmediy  Год назад +1

      Thanks Frank. It’s what I try to show

  • @insanechevy91
    @insanechevy91 Год назад +3

    Guy reminds me of a old guy I worked with last summer wired aleast 4 boxes with him more then I can remember service calls for light fixtures and ceiling fans and outlet replacements lol cool guy 😂

  • @germangomez7097
    @germangomez7097 Год назад +6

    Perfect explanation. Just what I was looking for. Thank you

    • @Askmediy
      @Askmediy  Год назад +1

      Awesome, glad I could help you out.

    • @blizte3
      @blizte3 Год назад

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @malindabrowning9240
    @malindabrowning9240 Год назад +2

    I think you’re hilarious. I recently wired up my breaker and the outlet for a dryer, and I definitely was a little nervous about turning on the breaker. You made me laugh so hard when you were teasing us about it.

    • @Askmediy
      @Askmediy  Год назад

      LOL But very true LOL.

    • @blizte3
      @blizte3 Год назад

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @briankeithhamilton4216
    @briankeithhamilton4216 10 месяцев назад

    Loved the Ending! Thank you🤗

  • @alsemi-back-up579
    @alsemi-back-up579 Год назад

    Great Video & Explanation of Wiring The RightWay!
    Thanks ForThe Upload
    Keep up The Great Work That You Do
    From Canada.

  • @CasualRican
    @CasualRican Год назад +5

    Thanks again for this video, I installed my dryer outlet by following your instructions. 👍

    • @Askmediy
      @Askmediy  Год назад +1

      Hope it works lol. Good deal

  • @Douglaskyle9191
    @Douglaskyle9191 10 месяцев назад +1

    If my wire to the black dryer outlet box is damaged by a dog I feel like I could cut it shorter and move the outlet higher instead of running all wire for my outlet. I have exposed silver wires that wrap around the core that are severed but dryer still works.

    • @Askmediy
      @Askmediy  10 месяцев назад

      Seems like it would be better to just replace the dryer cord.

    • @Douglaskyle9191
      @Douglaskyle9191 10 месяцев назад

      The outlet it plugs into is damage but not the actual cord to the dryer. A dog ripped open the sheet rock and began to tear open the wire leading to the outlet. I found this when getting my house ready to sell. The old owners left me this surprise and I have been living with it for 6 years lol Also the outlet is against the floor which I think I saw is not code anyways. 1987 home

    • @Askmediy
      @Askmediy  10 месяцев назад

      @@Douglaskyle9191 There is no code on the height of the outlet. If the wire is coming above it, you should be able to just raise it up to good wire.

  • @skippy493
    @skippy493 Год назад +2

    Hey man when are you going to post some new videos I really like your videos

  • @alangloria939
    @alangloria939 7 месяцев назад

    I was convinced until the end 😅 adrenaline just shocked my body

  • @melquemcleash6607
    @melquemcleash6607 11 месяцев назад

    This guy is a good teacher!

  • @CraigMoore-m2w
    @CraigMoore-m2w 11 месяцев назад

    Excellent explanation... should I use 10/3 romex to the panel from a 30 amp inlet plug for a generator (7500 running watts)? Or can I use 10/2 romex?

  • @lionelbutnotrichie7703
    @lionelbutnotrichie7703 5 месяцев назад

    Is there code for how far or close an outlet can be to the circuit box. I have to move my dryer to the opposite wall and the opposite wall contains the breaker box

    • @Askmediy
      @Askmediy  5 месяцев назад

      No not at all. Distance, yes. But nothing you need to worry about.

  • @mikebartoli4755
    @mikebartoli4755 Год назад

    That was just like standing next to my uncle while he's teaching me something! Well done sir, thank you making this tutorial.

    • @Askmediy
      @Askmediy  Год назад

      Very nice to hear. Thank you very much

    • @blizte3
      @blizte3 Год назад

      Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @hamsbyyams
    @hamsbyyams 8 месяцев назад

    “Let’s just say this is being inspected. WhiCh iT’s sUppOSed tO Be 🤪.” Had me cracking up lol

  • @SAWA-nx5co
    @SAWA-nx5co Год назад

    I spent few hours to find this. Thanks. You explain all from A to Z)))

  • @Ojeramup12
    @Ojeramup12 6 месяцев назад

    Can the green ground wire be connected to the white ground port? On 10;00 the wire is not connected.

    • @surferdude642
      @surferdude642 3 месяца назад

      No. Only to the green ground screw and never connect a ground wire to a neutral intended location. The neutral and ground are bonded at first disconnect means (usually the main panel) and nowhere else.

  • @troyandeviegray9736
    @troyandeviegray9736 Год назад

    It looks like the wiring on the hot water tank are 12 ga is 10ga okay for the run of about 10 ft and 10ga 3 wire outfit a dryer that’s even closer to the power panel, also I have a Meg welder the plug has a ground and a small and large knife blade the the outlet shows 120/240 at 50amp, how big should the wire be and what size breaker do I need

  • @theadventuresofchris1409
    @theadventuresofchris1409 Год назад

    thank you for making this video

  • @jenniferowen-ep2gp
    @jenniferowen-ep2gp Год назад +1

    Tbis is a dumb question, but, you said 30 Amp breaker. And it's a double breaker... does that mean 15 and 15? Or 30 and 30

    • @Askmediy
      @Askmediy  Год назад +1

      Not dumb at all. This means the total protected circuit is 30 amp

  • @ChristianHany-y7y
    @ChristianHany-y7y 9 месяцев назад

    Excellent video

  • @nickdiamond7595
    @nickdiamond7595 Год назад +1

    0:45 He's giving us the neutral finger

  • @fuqui035
    @fuqui035 6 месяцев назад

    The plate cover had Togo first behind the plug

  • @djreag8614
    @djreag8614 Год назад

    HEY DOMINIC ,YOU DA MAN ,COME UP TO NOVA SCOTIA AND DO SOME ELECTRICAL ,,

  • @bobbydbuilder2873
    @bobbydbuilder2873 Год назад

    I have old air compressor with a 10.20 nema. The only outlet I could find does not have a ground screw. Just 2 gold hot and silver neutral. I need some advice or a quick how to. Does it need to have a ground or just wire as is?

    • @Askmediy
      @Askmediy  Год назад

      Are you sure it's 220 volt?

  • @LetsGo6009
    @LetsGo6009 8 месяцев назад

    Thanks!

  • @tomassoyweyvon4902
    @tomassoyweyvon4902 Год назад

    Hey, Piasan...you mentioned Old vs New dryers with electronics, the question now is, the home dryers are wired with two wire 10, i had a new washer dryer installed with electronics, should i convert the two wire to three 10 ???? access is no problem

    • @Askmediy
      @Askmediy  Год назад

      Funny you say “piasan” I’m in Italy right now lol. Yes, you should if you can. Because you’ll need the two hots and the neutral. Ground of course

    • @tomassoyweyvon4902
      @tomassoyweyvon4902 Год назад

      @@Askmediy Hey, grazie per la reposta..I will do that...Godere!!!

    • @tomassoyweyvon4902
      @tomassoyweyvon4902 Год назад

      in addition i found out 1996 was the cutoff for three prong vs 4 per N.E.C., again Thanks

  • @hwl6969
    @hwl6969 Год назад

    Does it matter if you use a blue plastic box or a metal one?

    • @DominickAmorosso
      @DominickAmorosso Год назад

      No, not at all but if you use a metal box, you will have to ground it

  • @mattkelley7890
    @mattkelley7890 11 месяцев назад

    Never showed a close up inside the box. THE MOST IMPORTANT PART

  • @ReyesCTR0025
    @ReyesCTR0025 Год назад

    Nice video!!!

  • @blizte3
    @blizte3 Год назад

    Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

    • @DominickAmorosso
      @DominickAmorosso Год назад

      That’s a big question, what did you test?

    • @blizte3
      @blizte3 Год назад

      power on but dryer will not heat up@@DominickAmorosso

    • @blizte3
      @blizte3 Год назад

      also it has power spin tumbler without heat
      of any kind, on any heat setting, no sparks nor signs electric discharging beyond normal@@DominickAmorosso

  • @Hayden-sp1ol
    @Hayden-sp1ol 10 месяцев назад

    Extra grond wire via pig tail...? ?? I lost

    • @Askmediy
      @Askmediy  10 месяцев назад

      Ground outlet to metal box via the ground wire coming in

  • @woodstream6137
    @woodstream6137 4 месяца назад

    Probably calling an electrician. I need to run a ground to old 3 prong dryer outlet, thankfully its like a foot away from the breaker. My 30yr old speed queen finally finally died and I'm loathing having to buy a new budget machine.

  • @susancasavant5227
    @susancasavant5227 9 месяцев назад

    what a goober

  • @valery9958
    @valery9958 2 года назад

    ρяσмσѕм

  • @davidcase4600
    @davidcase4600 4 месяца назад +1

    Unsat, unsafe. If you use a metal box, ground it

  • @jacknelson4212
    @jacknelson4212 Год назад +4

    Great video. Only one I could find that hooked up the 4 wires and breaker in the breaker box. Also good explanation for the reason from going from 3 to 4 wire recepticle.

    • @jesserentas7425
      @jesserentas7425 Год назад

      Bro you ain't kidding I'm looking at these other videos thinking where in the world do the other 2 wires go christ!😂

  • @davidgasperlin6807
    @davidgasperlin6807 Год назад +4

    Great video im putting in a new line to my dryer so this really helps

  • @VicToR_Rider
    @VicToR_Rider 3 месяца назад +1

    Lol u nailed it with hearing a pop and the wife yelling fire😅 I messed up changing dryer plug. Mixed the black and white.

  • @AngelerFils
    @AngelerFils Год назад +3

    00:43 The counting made me burst out laughing 🤣🤣

  • @youngjimmystro8176
    @youngjimmystro8176 5 месяцев назад +1

    Lmao I love the ending man thanks for this video. Very helpful. I think I mis connected my outlet thanks for this!

    • @Askmediy
      @Askmediy  5 месяцев назад

      Thanks buddy, glad you liked it.

  • @Shadi2
    @Shadi2 2 года назад +1

    By any chance, is your brother a botanist?

  • @marineguy4eva
    @marineguy4eva 2 года назад +1

    That neutral wire doesn't give a.....!

  • @bryanlipscomb8918
    @bryanlipscomb8918 Год назад +1

    You funny dude. Great tutorial

  • @TonyyFlow
    @TonyyFlow 2 года назад +1

    FIRST!

  • @DelmaRaySmithJr
    @DelmaRaySmithJr Год назад +1

    Funny way of sharing what you know, in a humorous manner, thx

    • @Askmediy
      @Askmediy  Год назад

      Can't be a stiff right.

  • @Slavic_Eagle
    @Slavic_Eagle Год назад +1

    Glad your uploading again!!! 💪🇮🇹

  • @juancruz4179
    @juancruz4179 Месяц назад

    Thanks for this good video.

  • @juanftuchezsandoval2031
    @juanftuchezsandoval2031 Месяц назад

    Thanks for the video you explain it perfectly exactly the way I want to hear thanks again

    • @Askmediy
      @Askmediy  Месяц назад

      Awesome, glad you liked it.

  • @sickntired2059
    @sickntired2059 Месяц назад

    You're good.

  • @foodstampz
    @foodstampz 9 дней назад

    Guy has to be from Queens or Brooklyn:)

    • @Askmediy
      @Askmediy  8 дней назад

      Nope, not even close.

  • @joshcapecod6098
    @joshcapecod6098 Год назад

    Good video. Except the breaker is required to be GFCI...since 2020. And best to check the dryer cord hookup as well....kind of big things.

  • @jsville2023
    @jsville2023 Год назад +1

    This guy is great. Subscribed.

  • @whoisradu
    @whoisradu Год назад

    Hey guys what if the new 30A breaker doesn’t fit in the old box? Do you just get two 30 breaker that are the same type as the old breakers and run the two hots to each? Thanks for any advice

  • @whoisradu
    @whoisradu Год назад

    You make me feel like I can actually do this, even though I am extremely terrified, L O L

  • @majinkakashi20
    @majinkakashi20 2 месяца назад

    Awesome video, thanks man

    • @Askmediy
      @Askmediy  2 месяца назад

      Thank you so mush

  • @happycamper137
    @happycamper137 Год назад

    Thank you for this video, I agree with all the comments. It really helped me, every electrician I talk to say they'll do it and don't. I learned what the wires are for and the positions. Which now gives me knowledge and confidence. Again, thank you.

  • @kavya1638
    @kavya1638 4 месяца назад

    gonna leak something here... your dryer doesn't need to be using 30 amps, in fact, just a few pico amps. the reason it draws so much is because it was designed this way (on purpose), ie, the electric company needs to make money somehow. all your electronics, really, are designed to operate in the high amp range. 15amp vacuum cleaner, blender motor, etc.. turns out, a little project that draws energy out of the air feeds a heating element in the "pico amp range" and gets just as hot as your dryer's heating element. thanks to a few advancements in this field, the electric company is guaranteed to go out of business. give it a few years..

  • @seanrobbins1916
    @seanrobbins1916 Год назад

    I would apprentice with you

  • @be4fourty
    @be4fourty Год назад

    Thanks for the video

  • @paulholloway5458
    @paulholloway5458 Год назад

    Brilliant Work, Thanks.Just needed a fresh reminder.

  • @stevenramsar456
    @stevenramsar456 Год назад

    Very helpful thanks😂😊

  • @josefcalderonromero8452
    @josefcalderonromero8452 Год назад

    Beautiful 🤩 exactly what I was looking for . Question. I want to install about 5-8 240 baseboard heaters in my basement. You think 2 30 amp circuits would be enough?

    • @Askmediy
      @Askmediy  Год назад

      Most baseboard heaters are 20 amp. Please follow the instructions for sure.

  • @lionwolf5768
    @lionwolf5768 11 месяцев назад

    Great video thank you!

  • @geyser3445
    @geyser3445 2 года назад

    I have a 220 volt electric hot water heater in my basement and want to add a switch at the top of my basement steps to turn it on and off. Can you show us how to do that and what switch to use? Thanks.

    • @Askmediy
      @Askmediy  2 года назад

      Just like any other switch. But it's a two-pole switch. Meaning that each side of the switch is for each hot. With 240 volts it's essential to switch both hots.

  • @christianahava
    @christianahava Год назад

    Top notch info

  • @jasonmacdonald27
    @jasonmacdonald27 Год назад

    GREAT VIDEO

  • @IamMattW.
    @IamMattW. Год назад

    Perfect! Exactly what I’ve been looking for. Nobody explains the panel part. And you made this video very entertaining! Hopefully my wife doesn’t yell at me though 🤣

    • @Askmediy
      @Askmediy  Год назад +1

      Good deal. Thank you so much

    • @blizte3
      @blizte3 Год назад

      @@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?

  • @robmorse5239
    @robmorse5239 Год назад

    Thanks... I really like you teaching style

  • @oliverlu3259
    @oliverlu3259 Год назад

    make it very clear to me. good job. thank you1

    • @Askmediy
      @Askmediy  Год назад

      Awesome. thank you so much.

  • @ricodinero4926
    @ricodinero4926 9 месяцев назад

    come on askmediy , you make it look easy.

    • @Askmediy
      @Askmediy  9 месяцев назад

      Because it is. You can do it

  • @djreag8614
    @djreag8614 Год назад

    Hey Dom, can I put neutral and ground wire on the same side in the panel box?

    • @DominickAmorosso
      @DominickAmorosso Год назад +1

      Sure, as long as it’s not a sub-panel

    • @djreag8614
      @djreag8614 Год назад

      @@DominickAmorosso THANKS DOM, TOO EXPENSIVE TO HIRE ELECT. SENIOR YA KNOW ,,, NOW ONE MORE QUESTION THE COPPER GROUND THATS BARE ,CAN I JUST ATTACH IT TO THE SCREW AT THE BACK OF THE BOX THEN CONNECT IT TO THE GROUND PLUG OPENNING ?.. PLUS THERE ARE STILL LIVE WIRES EVEN THOUGH THE PANEL IS SHUT OFF RIGHT?