Oxygen Analyser Zirconia Detector ZR22G | Overview in Hindi

Поделиться
HTML-код
  • Опубликовано: 8 сен 2024
  • hello friends,
    in this vedio- I have show you that yokogawa sensor detector parts and wiring .
    I have also upload yokogawa zirconia replacement and calibration.
    so watch full vedio till end if any doubt or querry so comment me on comment section I will always ready help for you friends .
    $$ Please Subscribe my channel $$
    👍👍👍 Like vedio & share vedio with your friends.
    🙏🙏🙏🙏thanks for watching my vedio 🙏🙏🙏🙏

Комментарии • 24

  • @mohsinraza9944
    @mohsinraza9944 6 месяцев назад +1

    Good video

  • @PankajKumar-zu1eo
    @PankajKumar-zu1eo 3 года назад +1

    Good

  • @arindamghatak
    @arindamghatak Год назад +1

    Sir, how are the calibration and reference gas tubes connected at their inlet ports ? They just appear to be straight pipes. Also, what is their diameter ?

  • @rishirajsahu1130
    @rishirajsahu1130 9 дней назад

    Sir pt 1000 wala rtd kaha par laga hota hai

  • @INDIANELECTRONICSREPAIR
    @INDIANELECTRONICSREPAIR Год назад +1

    Sir thermocouple kaise change karega agar kharab ho gya hai to

  • @suvankarsasmal7825
    @suvankarsasmal7825 3 года назад +1

    Actually sir hamara plant me jo O2 analyser hai usme cal port and ref port me dono air line lagi hui hai... Aur us line me chota rota meter laga hua hai.... Kya cal ke time kuch flow ko maintain karke hum cal port me air dete hai kya.... Wo flow kitna rakhna hai min Or max....?? Ye v thoda clear kar dijiye na pls.... Apko bahut dhanyavaad video k liye

    • @PowerPlantInstrumentation
      @PowerPlantInstrumentation  Год назад

      Reference Port & Cal port . Reference port for atmospheric air (20.9% O2) and cal gas used for Zero and span calibration. So flow maintains both port which give you in manual data sheet . Otherwise will make separate video . Thanks for your comment 🙏🏻

  • @yvs.channel7422
    @yvs.channel7422 Год назад +1

    Heater it's not reached to 750deg hearter was automatically tripped

  • @akmalrajpoot6042
    @akmalrajpoot6042 Год назад +1

    Cell ki resistance kesy check kary gye?

  • @suvankarsasmal7825
    @suvankarsasmal7825 3 года назад

    Aur sir calibration ke time cal wala port me hum standard gas dete hai zero cal k liye 0.4% o2 gas and span cal k liye port ko sirf khol ke rakh te hai...but span cal ke liye kya hum instrument air supply(6kg/cm2) us cal port me dal sakte hai kya???.. Agar dal sakte hai to kitna pressure maintain karna hai..... Sir pls reply dijiyega....

    • @PowerPlantInstrumentation
      @PowerPlantInstrumentation  3 года назад

      Span cal ke liye aap Instrument air de sakte hain. Instrument open area me install hai aur clean air available hai to jaroorat nahi hai Instrument air ki . Zero/span cal ke liye aapko 600+/- 60 ml/min maintain karna hota hai .

    • @arindamghatak
      @arindamghatak Год назад

      @@PowerPlantInstrumentation Sir, instrument air kaa main purpose kya hai ?

  • @suvankarsasmal7825
    @suvankarsasmal7825 3 года назад

    Sir referance gas kab use karna hai??? Ya fir use karne ka jarurat nhi hai... Matlab ref gas kounsa hai....

    • @PowerPlantInstrumentation
      @PowerPlantInstrumentation  3 года назад

      Reference gas matlab Instrument air aur agar apka analyzer open area me installed hai to koi jaroorat bhi nahi hai ref gas ki .

  • @nileshbagwe9018
    @nileshbagwe9018 Год назад +1

    What is the price?

  • @instrumentpower6380
    @instrumentpower6380 2 года назад

    Sir working principal bato