Oxygen analyser. Why Oxygen analyser installed between economizer and airpreheater ?

Поделиться
HTML-код
  • Опубликовано: 6 ноя 2024

Комментарии • 63

  • @ashishjaiswal6140
    @ashishjaiswal6140 4 года назад +3

    This is the most important video for BOE exam tq Sir ji

  • @ashishvitekar3474
    @ashishvitekar3474 3 года назад +2

    Very very nice explain and informative videos.
    How to monitor and check that furnace conditions are OK with the help of O2 analyser.
    What are the standard Value of O2 to maintain healthy combustion in furnace.
    Thank you

  • @parveenkumarswain5070
    @parveenkumarswain5070 Год назад +1

    Why fuel is completely not burnt before inlet of economiser pls explain

  • @sujitpadvi
    @sujitpadvi 3 года назад +1

    Bahut badhiya..laga yj sir..👍

  • @sandeshsonawane3868
    @sandeshsonawane3868 3 года назад +1

    Outstanding explanation 👍

  • @krunalpuri4707
    @krunalpuri4707 4 года назад +1

    Wow nice video sir
    Ke video MDC Ka baneya

  • @worldinstrumentationengineer
    @worldinstrumentationengineer 2 года назад +1

    excellent ji

  • @babloochauhan9949
    @babloochauhan9949 2 года назад +1

    Once through boiler per video banayia

  • @sachinsaraswat1186
    @sachinsaraswat1186 3 года назад +2

    Everything is good .....thoda sa auto focus ka problem hora h 👍

  • @ashishvitekar3474
    @ashishvitekar3474 4 года назад +1

    Very good information, I am got satisfaction

  • @Tahlkavlogs
    @Tahlkavlogs 5 месяцев назад +1

    Bhaiya ecses air kaha se dete hai

  • @shashibhatia167
    @shashibhatia167 2 года назад +1

    I wanna know 1 thing that is at economizer inlet,the temperature of flue gas is 430°C to 450°C.It means that at inlet of economizer,the temperature is higher than the ignition temperature of FC, Hydrozen and sulphur.It means that ki complete combustion to economizer ke inlet pe hi ho jaaega due to more temperature at economizer inlet.So,why we can't install Oxyzen analyzer at economizer inlet?

    • @yjsuccesstrack7275
      @yjsuccesstrack7275  2 года назад +1

      Completely combustion tem par HI to oxygen check karenge dost...... Complete combustion ke Bad jo air hoga wahi to excess Air hoga ok

  • @ashishjaiswal6140
    @ashishjaiswal6140 4 года назад +1

    Superb video sir

  • @arindamghatak
    @arindamghatak 3 года назад +1

    How do you get the following conclusion as highlighted at 5:55....10% increase in excess air will cause 3% increase in fuel consumption ?

  • @nareshswami5562
    @nareshswami5562 4 года назад +1

    Nice video sir

  • @ompalyadav824
    @ompalyadav824 2 года назад +1

    Thank you very much sir 🙏
    Sir mujhe online coaching krna h

  • @rakeshchawhan5277
    @rakeshchawhan5277 3 года назад +1

    Super

  • @subashpal9403
    @subashpal9403 4 года назад +1

    Nice video

  • @mahakal5169
    @mahakal5169 4 года назад +2

    super sir

  • @er.shambhu4520
    @er.shambhu4520 4 года назад +1

    Sir is pr numerical video plzz

  • @PankajYadav-zg3co
    @PankajYadav-zg3co Год назад +1

    Tq

  • @kesarinandan8181
    @kesarinandan8181 4 года назад +1

    Kitne tph k boiler me kitne inches ka IBD ya CBD valve lagayA jata hai.

    • @yjsuccesstrack7275
      @yjsuccesstrack7275  4 года назад +1

      CBD ka pipe boiler capacity se sirf 5% blow down kar sake ayese designed kiya jata hai....
      And IBD jo hai TDS and BMCR par designed kiya jata hai eske liye.. Jaise aapka boiler 10 kg/cm² par steam generate krta hai to 1" ke pipe se 480 kg water relig krta hai... Esliye pahale aapko blow down percentage nikalna pdega fir pipe diameter and blow down time kitna hona chahiye o nikal skte hai

  • @ivanfadillah1936
    @ivanfadillah1936 2 года назад +1

    hi sir, could you provide the information in English? I need to understand that. Thanks

  • @sujitroy3860
    @sujitroy3860 2 года назад +1

    What is full form of nm3 ?

  • @ashishjaiswal6140
    @ashishjaiswal6140 4 года назад +1

    Sir please water circulations and steam circulations ka video Nanaiye

  • @arindamghatak
    @arindamghatak Год назад +1

    You have written Flue gas as Fuel Gas. Kindly correct this.

  • @krunalpuri4707
    @krunalpuri4707 4 года назад +1

    Sir o2 ziyda or o2 kaamho Jai to kaykari ge

  • @vishalsarang2999
    @vishalsarang2999 4 года назад +1

    DCS मै कसें करे करे drum leval control plz shear this video

  • @ompalyadav824
    @ompalyadav824 2 года назад +1

    Sir total kitna o2rkhe

  • @Sandeepyadav-wu2un
    @Sandeepyadav-wu2un 4 года назад

    Ok sir ji

  • @pradipjain4670
    @pradipjain4670 4 года назад +1

    Thankyou

  • @vinaybastawade7068
    @vinaybastawade7068 3 года назад +1

    Supb sir

  • @pareshpande7111
    @pareshpande7111 3 года назад +1

    Oxygen percentage ketna hona chahiye

    • @yjsuccesstrack7275
      @yjsuccesstrack7275  3 года назад

      Sab fuel ke liye alag alag hota hai dost,,, ldo ke liye 4-5%
      Cog + BFG ke liye 3%
      Pcm ke liye 5%
      Coal ke liye 5-6%

  • @pradipjain4670
    @pradipjain4670 4 года назад +1

    Ok

  • @ompalyadav824
    @ompalyadav824 2 года назад +1

    Sir good morning please sir mo nambar

  • @nirajsinhmakwana3359
    @nirajsinhmakwana3359 3 года назад +1

    Nice video sir