Very very nice explain and informative videos. How to monitor and check that furnace conditions are OK with the help of O2 analyser. What are the standard Value of O2 to maintain healthy combustion in furnace. Thank you
I wanna know 1 thing that is at economizer inlet,the temperature of flue gas is 430°C to 450°C.It means that at inlet of economizer,the temperature is higher than the ignition temperature of FC, Hydrozen and sulphur.It means that ki complete combustion to economizer ke inlet pe hi ho jaaega due to more temperature at economizer inlet.So,why we can't install Oxyzen analyzer at economizer inlet?
CBD ka pipe boiler capacity se sirf 5% blow down kar sake ayese designed kiya jata hai.... And IBD jo hai TDS and BMCR par designed kiya jata hai eske liye.. Jaise aapka boiler 10 kg/cm² par steam generate krta hai to 1" ke pipe se 480 kg water relig krta hai... Esliye pahale aapko blow down percentage nikalna pdega fir pipe diameter and blow down time kitna hona chahiye o nikal skte hai
This is the most important video for BOE exam tq Sir ji
Welcome dear
Very very nice explain and informative videos.
How to monitor and check that furnace conditions are OK with the help of O2 analyser.
What are the standard Value of O2 to maintain healthy combustion in furnace.
Thank you
Why fuel is completely not burnt before inlet of economiser pls explain
Bahut badhiya..laga yj sir..👍
Thank you
Outstanding explanation 👍
Wow nice video sir
Ke video MDC Ka baneya
excellent ji
Once through boiler per video banayia
Everything is good .....thoda sa auto focus ka problem hora h 👍
Sorry I will try my best
ji bilkul.......but nice
Very good information, I am got satisfaction
Thanks and welcome
Bhaiya ecses air kaha se dete hai
I wanna know 1 thing that is at economizer inlet,the temperature of flue gas is 430°C to 450°C.It means that at inlet of economizer,the temperature is higher than the ignition temperature of FC, Hydrozen and sulphur.It means that ki complete combustion to economizer ke inlet pe hi ho jaaega due to more temperature at economizer inlet.So,why we can't install Oxyzen analyzer at economizer inlet?
Completely combustion tem par HI to oxygen check karenge dost...... Complete combustion ke Bad jo air hoga wahi to excess Air hoga ok
Superb video sir
Keep watching
How do you get the following conclusion as highlighted at 5:55....10% increase in excess air will cause 3% increase in fuel consumption ?
Nice video sir
So nice
Thank you very much sir 🙏
Sir mujhe online coaching krna h
Hmm start kr rahe hai jaldi
Super
Nice video
Thank you so much
super sir
Sir is pr numerical video plzz
Tq
Kitne tph k boiler me kitne inches ka IBD ya CBD valve lagayA jata hai.
CBD ka pipe boiler capacity se sirf 5% blow down kar sake ayese designed kiya jata hai....
And IBD jo hai TDS and BMCR par designed kiya jata hai eske liye.. Jaise aapka boiler 10 kg/cm² par steam generate krta hai to 1" ke pipe se 480 kg water relig krta hai... Esliye pahale aapko blow down percentage nikalna pdega fir pipe diameter and blow down time kitna hona chahiye o nikal skte hai
hi sir, could you provide the information in English? I need to understand that. Thanks
What is full form of nm3 ?
Normal cubic meter
Sir please water circulations and steam circulations ka video Nanaiye
Bilkul
You have written Flue gas as Fuel Gas. Kindly correct this.
This is right dear
Sir o2 ziyda or o2 kaamho Jai to kaykari ge
Fd and wind Box pressure maintan karo ho jayega
DCS मै कसें करे करे drum leval control plz shear this video
OK dear banaunga
Apka contact no plz send kijiye...
Esme ni kr skta dear... yogendrajaiseal05@gmail.com
@@yjsuccesstrack7275 ok koi baat nahi
@@yjsuccesstrack7275
Hello
Sir total kitna o2rkhe
3-4%
Ok sir ji
Thankyou
Welcome
Supb sir
Oxygen percentage ketna hona chahiye
Sab fuel ke liye alag alag hota hai dost,,, ldo ke liye 4-5%
Cog + BFG ke liye 3%
Pcm ke liye 5%
Coal ke liye 5-6%
Ok
Sir good morning please sir mo nambar
No send kro Mai call krta hu
Nice video sir
Thanks