Turns me jyada her pher karne se kaafi dikkat aayegi. Har ek motor ka critical resistance hota hai. Usse kam hone par motor overheat hokar jal jayega. Aap bas itna hi kar sakte hain ki 100 turn standard hai toh 90-110 ke beech hi turns rakhe. 90 se neeche heat karega aur 110 se upar speed ki dikkat aayegi. Aur haa, stator me wire aur turns ko thoda bahut hi negotiate kiya jata hai taaki full utilisation ho sake. Pehle actual turns determine kijiye, phir gauge ke anusaar optimize kijiye.
Sahabaj bhai 1 questions aayi video watch karne ke baad ki agar ye mistake se old wire turns nahi h ya koi aur mechanic ne old wire cut ki aur wo winding nahi kar paya to kaise motor ki slot ki golai ko mm me slote ki hall kitni moti h aur kitna number ki gauge aur turns calculate kar sake
3HP ke neeche series connection hi kiya jata hai. Agar abhi aap parallel connection karne jaoge toh motor jal sakta hai. Single phase ke liye turns aur gauge change ho jate hain. Iska dhyan rakhna padta hai. 3 phase me 3 running coil hote hain aur 1- phase me sirf ek. Issliye wire bhi kaafi heavy gauge ka use hoga. Akela running coil poora ya 80% load lega. Starting coil toh bas thoda push karne ke liye hota hai.
24 और 36 स्लोट के किसी भी खाली स्टेटर में 2 एचपी और 3 एचपी सिंगल फेज में वायडिंग करने के लिए swg wire number nd coil group, pitch, turn nd wire weight कैसे calculate करते है उसका तरीका बताइये
Koi ye bhi batao bhai ji agar kit cooler ya exjhost cooler he to ise grahak bolta he meri light single fase me bahut low voltage aata he isliye dabul fase chalata hu Lekin kabhi kabhi 240 volt se aage lagbhag 290 volt tak pahunch jata he Tab grahak bolta he meri moter dabul fase me bhariye , to ham parfect swg aur turn me kya badlaw kare ki moter me complend na aaye Aur badlaw raning aur starting dono me karna padega ya fir keval raning me please answer deejiye 🙏🙏
मोटा करने से A बढ़ता है पतला करने से A कम हो जाता है एकतो आप बोल रहे हो पतला कर दो उसमे फिर टर्न भी बड़ा दो इससे तो रेजिस्टेंस बड जायेगा स्पीड भी कम हो जायेगी लोड भी सही नही लेगा
Thanks 4 All Keep Support
And Keep smiling ☺️ Always
Apana number dijiye
Motor ki power watt par Kiya effect hoga
Sir agar dubble guge rahega to kaise kalcolation karenge
Thanks bro information dene ke liye aap ki video Dekhe main motor winding karta hun Aaj Tak Kisi Guru ke pass mein nahin Gaya
Assalamu alaikum wa Rahmatullahi wa barkathhu
Samjhana bahut achcha hai
verry Verry important and nice information sahabaj bhai
Thanks Bhai jii
Very nice information. ...thanks you ..
Very good jankari
Very good explanation
Thanks bhai Jiii 🥰🥰🥰
Welcome brother
Thanks brother aapne bahut achha bataya
Very very nice video bhai ji
Thanks u so much 🥰🥰 bhai ji
You are great sr.
Very Usefull information,
Good work bhaijaan
Achhi jankari hai sir
Very nice video bhai ji 🙏
Shukriya Bhai jii
Good information sir ji 🙏🙏
Thanks Bhai jii 🥰
Zabardast
Very use full vidio Nise sir
Thanks bhai jii 🥰
Very very nice bhai ji
Thanks Ajay Bhai jii 🥰
@@SahabajKhan aur kese hai
You are great.thankyou
Turns me jyada her pher karne se kaafi dikkat aayegi. Har ek motor ka critical resistance hota hai. Usse kam hone par motor overheat hokar jal jayega.
Aap bas itna hi kar sakte hain ki 100 turn standard hai toh 90-110 ke beech hi turns rakhe. 90 se neeche heat karega aur 110 se upar speed ki dikkat aayegi. Aur haa, stator me wire aur turns ko thoda bahut hi negotiate kiya jata hai taaki full utilisation ho sake. Pehle actual turns determine kijiye, phir gauge ke anusaar optimize kijiye.
Super information thanks
Sir resistance to unbalanced ho Jayega.
Sir ji very nice
Nice video sir ji
Vry nice bro
2hp,3 phase ,36 slot ,4pole , coil pitch 1-9,2-10,3-11 , 22 swg ka copper coil dal sakte hai kya bhai plz reply
Nic video sir
Thanks u
Helpful video thanks
Thanks Bhai ji
Sahabaj bhai 1 questions aayi video watch karne ke baad ki agar ye mistake se old wire turns nahi h ya koi aur mechanic ne old wire cut ki aur wo winding nahi kar paya to kaise motor ki slot ki golai ko mm me slote ki hall kitni moti h aur kitna number ki gauge aur turns calculate kar sake
Good quotations
Good sir
Sir
Aluminum & cuper me yahi mm vala formula use kre kya ??
Sir 4 slot 2 Pole 350 watt 1phase motor me kitne turn or kitne no Gage lagega
सर कहीं पर 220वोल्ट से ज्यादा या कम आता है तो उसके लिए टर्न और गेज़ का क्या करे
Good niformesom
Sir swg agar 17 ho or wo mere paas na ho to me swg 20+21+22 de de to turn km ya jyada karne ki to koi jrurat nahi plz btaye sir 😊
Agar Ham gauge ko up down Karenge to hamare current arthat ampere mein difference aaega Uska Kya Samadhan Karenge ki motor Hamare utane hi empier le
Sukriya ji
Thanks bhai jii 🥰
Sir aap hame kirloskar monoblock 3 hp 2.2kw kds 312 ka winding data batane ki kripa kare Mai bahut pareshan hun
Bhai ji mai wanding ka sikna chata hu
Plzz bhai ji help
Mujhe apke hi trh kam krna hai
Thank kiyou brother
Bhaiya low voltage se high voltage or high voltage me motor banane ka tarika batayen please
सर अगर किसी टुल्लू मे 22 नं तार लगा है क्या उसमे 23 नं डाल सकते है बताए सर
Mother ke cannetion to sar ji aise hi rahenge jase pahale wair namber up down karne par ya cannetion change karne hoge
Mast bahi
Thanks deepak bhai
2 hp ki motar single phase mein banaya hai or series connection Kiya hai motar load nahi le rhi hai ushke connection parallel mein kar de
Please reply
3HP ke neeche series connection hi kiya jata hai. Agar abhi aap parallel connection karne jaoge toh motor jal sakta hai.
Single phase ke liye turns aur gauge change ho jate hain. Iska dhyan rakhna padta hai. 3 phase me 3 running coil hote hain aur 1- phase me sirf ek. Issliye wire bhi kaafi heavy gauge ka use hoga. Akela running coil poora ya 80% load lega. Starting coil toh bas thoda push karne ke liye hota hai.
Sir, data change Ho jayega, motor ka torque (takat) cum ho jayegi, hum kisi ko guarantee nahi de payege
24 और 36 स्लोट के किसी भी खाली स्टेटर में 2 एचपी और 3 एचपी सिंगल फेज में वायडिंग करने के लिए swg wire number nd coil group, pitch, turn nd wire weight कैसे calculate करते है उसका तरीका बताइये
Supper
Sir mujhe finense se ceiling fan waindig machine chahiye ho sake to Karwa dijiye sir 2 Machine kharidna h
Sr.hamko aap se sikhana hai kuchh bataiye sar kya karna hoga
Sar ji har slot mein sem turn aaega
Sir 19.5 no hai 45trn or me 22no dbble dalenge to trn km ho ja rha o kese solv kre
Masallah Allah
Koi ye bhi batao bhai ji agar kit cooler ya exjhost cooler he to ise grahak bolta he meri light single fase me bahut low voltage aata he isliye dabul fase chalata hu Lekin kabhi kabhi 240 volt se aage lagbhag 290 volt tak pahunch jata he
Tab grahak bolta he meri moter dabul fase me bhariye , to ham parfect swg aur turn me kya badlaw kare ki moter me complend na aaye
Aur badlaw raning aur starting dono me karna padega ya fir keval raning me please answer deejiye 🙏🙏
बहु त खुब
Awesome mind bro.
Thanks bhai
Sar ji har slot ke bare mein thoda jankari
Motor ke ampear per koi problem to nhi hoga
Useful.
Thanks bro
Sir ji duble 21 swg nikla h uska kya kre
Sir khali motar ka data kese nikale 1fas 2fas 3fas ka or 2fas se 3fas or 3fas se 2fas ke karne ke liya tarn me or gej me kya antra kre plizz sir
Thanks sir
Sar silver copper karne ka kuchh Tarika batao kaise karen hai
Bhai kya hum washing spin motor ko 2800 rpm me wind kar skte h please video bnao
Compny kitna deti hai
Compny kitna rpm me banati hai
Sir 8+8 celling fan ka alluminium data bta dijye
Bangladesh me a tarika chale ga vai?
Sir data computer kise karte hai
Thanks
Welcome brother
एरिया कवर हो जाएगा। Amp कंपनी जो देती हैं उसमें accuracy नहीं आती है। Torq में भी कमतरता होती है। SWG को पतला करने से पानी का flow कम आता है।
सही पकड़े है 😂😂😂😂😂
I agree with you answer
Ok sir
Thank
Bina dekhe motor m coil weight kaise pata kare,bataye
किसी भी मोटर में कपेसिटर किस माप का लगाएं ये किस पर depand करता
Sir samarsebal motor ka gej change karne ka Tarika bataiye
सर जी क्या टर्न के हिसाब से वायर का वजन भी निकाल सकते हैं कैसे यह भी बताऐ सर कि कितना वायर लगेगा सर जरूर वीडियो हमें डाल दे सर
😂😂😂 nhi hoga qk desi wire me weight jyada hota hai aur company ki halki hoti hai
130 गेज के वायर में कितने MM होते हैं कृपया बताने की कृपा करें
Assalam o Alikum bhai kia hl hy theek ho
bhai ap es tarha (writing ) kran
hindi writing mein samujh nahien aati
Mujhe tumhari Video ka notification Nahi milta hai
Bhai Ji Aage se m Jb v video upload kiya karunga aapko msg daal diya karunga Fb pr ya insta pr
Sir Ji Khali stator ka calculation betaine
👍👍👍❤️
मोटा करने से A बढ़ता है पतला करने से A कम हो जाता है
एकतो आप बोल रहे हो पतला कर दो उसमे फिर टर्न भी बड़ा दो इससे तो रेजिस्टेंस बड जायेगा स्पीड भी कम हो जायेगी लोड भी सही नही लेगा
I agree with you answer,
Swg 37 se 720 turn hai to swg 36 se karna hai to kaise ghataye.
650 ke samthing
Sir ji Kali stator ka calculation bataiye
Sir cepasitor lagane ka formula
Cooler machine winding ka data kase nekale
Gauge proper lgta ho fr bhi jal jati hai kyo
Bhai khali stetor la data batao
Bhai phir to hm 35 no.se iska mm banaa denge
Wire ka Wight kaise nikalw
Sir aap se sampork kese hoga apna nombar dijiy
Sar merajakari tesata tega
सर सबमर्सिबल का बताओ
बिल्कुल भाई मेरी भी बहुत इच्छा है
Sir easi kisi bhe moter ka swg chang koi kar sakta h app wrong jankari de raha ho
Sahbaj bhai mujhe hand coil machine 5500 wala
Ji Bhai Ji mil Jayega Call Kre 9050785855
Motor bar bar jalti kyo hai
amp Kam nahi hoga
Jo aadmi chart dekhe oh aadha adhoora winder hai
Namaskar bhai kya aap ka mobile number mil sakta hai thanks
Thanks bro