Oil System YK York Chiller

Поделиться
HTML-код
  • Опубликовано: 7 сен 2024

Комментарии • 56

  • @HVACTIME
    @HVACTIME  10 месяцев назад

    YK online training at chilleracademy.com
    Get Confidence and Accuracy with this Troubleshooting Guide!
    hvactime.shop/products/yk-tech-sheet

  • @jpac2g
    @jpac2g Год назад +10

    This video is pure gold, thank you for sharing your knowledge. Videos like this weren't available, and in this detail, just years ago. I can tell that you know your stuff, keep them coming please, Thank You!

  • @bill8985
    @bill8985 Год назад +3

    It has been decades since i had to buy, install, and maintain one of these guys... Your explanation was super clear and brought back some nostalgia. Thanks!

  • @Erikmiles87
    @Erikmiles87 Год назад +1

    Thanks. Was explaining eductor lines to my apprentice. I’m going to show him this video so he can see the internals

  • @twilks7878
    @twilks7878 Год назад +1

    I love these chiller videos, I work at JCI and you explain better than my JM.

  • @EverythingHVACR
    @EverythingHVACR Год назад +1

    Great information Holden, thanks

  • @user-sx1rv9kb2q
    @user-sx1rv9kb2q 6 месяцев назад

    I am a JCI YK centrifugal turbo chiller engineer.
    The video was very helpful.
    I would appreciate it if you could upload more videos. I am curious about the role of each material inside the chiller. The information about the oil line is similar to what I thought. thank you

  • @DannyBokma
    @DannyBokma Год назад

    Ow man, all this information, thanks so much for sharing these insights! What a wonderful world an time we live in ^^!

    • @HVACTIME
      @HVACTIME  Год назад

      Thank you for the support!

  • @TheRenaissanceBuilder
    @TheRenaissanceBuilder Год назад

    Good video bud.
    I giggled a bit over the camera angles only because I recognize how difficult entertaining camera angles can be to find sometimes

  • @onesimpleman1
    @onesimpleman1 Год назад

    Excellent video on oil system

  • @GordonHVACR
    @GordonHVACR Год назад

    Thanks for making this outstanding video! Proud of your hard work !

  • @tylerferrell2959
    @tylerferrell2959 Год назад

    Dude you kill it in these videos

  • @fathmasameer7523
    @fathmasameer7523 Год назад

    Great experience you deserve more subscribers dude thanks

  • @gatoguevara71
    @gatoguevara71 Год назад

    Great job thank you for sharing your experience

  • @wata_laf
    @wata_laf 9 месяцев назад

    Wildly informative 👍🏼👍🏼

  • @DronePilot4k
    @DronePilot4k 4 месяца назад

    Thanks!

    • @HVACTIME
      @HVACTIME  4 месяца назад

      Thank you very much!

  • @bornjanuary25
    @bornjanuary25 Год назад

    Kindly make review for Carrier chiller GX30 and 30GT with your amazing manner ( operation , service and maintenance )

  • @texture6
    @texture6 Год назад

    Thank you to infinity

  • @igariokmihailov4461
    @igariokmihailov4461 7 месяцев назад

    great video buddy, i have a small leak on the oil sight glass, could be the o-ring , do i have to drain the oil in order to replace it, or i have to remove the front plate also? Thanks in advance

  • @DronePilot4k
    @DronePilot4k 4 месяца назад

    Thanks for the video , appreciate you taking the time to share. What is the sequence for the solenoid on the oil return line? Is it open during on cycles and closed on off cycles?

    • @HVACTIME
      @HVACTIME  4 месяца назад +1

      Yes, and the oil temp will influence it opening

    • @DronePilot4k
      @DronePilot4k 4 месяца назад

      Thank you very much , so if the oil temperature in the sump is already low it will stay closed?

    • @HVACTIME
      @HVACTIME  4 месяца назад +1

      @@DronePilot4k exactly

  • @dmc357
    @dmc357 Год назад

    Great video!!

  • @brandonwalker4842
    @brandonwalker4842 9 месяцев назад +1

    Did you have to recover all the refrigerant to work on the sump or where you able to isolate. I have to work on oil sump. I have isolation valve on discharge piping going to condenser but nothing on the evap. So, my question to you is do I need to recover the entire charge.

    • @HVACTIME
      @HVACTIME  9 месяцев назад

      Yes, you wiil need to recover charge.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC Год назад

    Good stuff

  • @hvac8826
    @hvac8826 Месяц назад

  • @justinkendollrozinek
    @justinkendollrozinek Год назад

    Super smart

  • @Henryolson09
    @Henryolson09 7 месяцев назад

    Ferncos and PVC on the pressure safety valves!? That might be worse than not piping them outside at all

  • @foodtravelxp24
    @foodtravelxp24 Год назад

    Dear boss my york centrifugal chiller a Alam coming oil-low differential pressure calibration. So i can remove this alarm??

  • @kobebryant4750
    @kobebryant4750 Год назад

    What is the meaning of oil variable speed pump contacts open? Plss help me

  • @jarredallen
    @jarredallen Год назад

    I hate opening york chiller oil sump. they are always in an awkward location. they either in between compressor and condenser shell or at the bottom of the shells.

  • @rmalanis13
    @rmalanis13 2 месяца назад

    Having issues with a yk right now. While running sump LOP is about 60psig and evap is 38 psig. Changed oil filter and eductor. All valves open. Oil return solenoid working. But eductor filter stays hot, could it be bad balance piston seal, or faulty/plugged eductor block? If any one can assist it would be greatly appreciated

    • @rmalanis13
      @rmalanis13 2 месяца назад

      To clarify Changed eductor filter, not block

  • @joshstevens9826
    @joshstevens9826 Год назад

    I'm curious, do you take annual oil samples?
    Or is it when a problem is suspected?
    Where I am wr do filters and oil samples with every annual we do.

    • @HVACTIME
      @HVACTIME  Год назад

      I do annual samples with lab analysis

  • @technicalfeatures5748
    @technicalfeatures5748 Год назад

    Sir can you tell me how to cooling YK chiller heartsink, i have facing this problem high heart sink temperature

  • @andrewjacks8671
    @andrewjacks8671 11 месяцев назад

    What does MTT mean? Multi-task trebuchet?

    • @HVACTIME
      @HVACTIME  11 месяцев назад +1

      Make The Time for your spouse and family with our busy schedules.

    • @andrewjacks8671
      @andrewjacks8671 11 месяцев назад

      @@HVACTIME MTT. I like it. Thanks for the in-depth videos. Much appreciated.

  • @user-rd5vm7si4o
    @user-rd5vm7si4o 8 месяцев назад

    please advice have you ever have this problem ?, I am getting the oil loss in oil sump chiller York YK Centrifugal. The oil seems goes to evaporator
    The above problems occurs after :
    1. We have changed the oil Return Solenoid
    2. add extra valve for changing the TXV oil temp control (so if we need to change the txv no need to transfer pump down the R134a)
    3. Change the new oil pump
    The actions that we already redone :
    1. change again the oil return solenoid to the old one
    2. change the oil cooler heat exchanger
    3. change the txv oil temp control to the old one, but the extra valve for service still there (because of welded)
    4. checking the oil block eductor inside the oil sump ( the springs are doing pretty well)
    The problem still remain ,getting the oil loss in oil sump chiller York YK Centrifugal. The oil seems goes to evaporator
    please advice, do you have any suggestion

    • @HVACTIME
      @HVACTIME  8 месяцев назад

      How much run time in-between trips?

    • @user-rd5vm7si4o
      @user-rd5vm7si4o 8 месяцев назад

      only about start up 5 minutes , the oil sump level already minimum. The chiller still can run, but we just turn off the chiller off because the low level oil

    • @user-rd5vm7si4o
      @user-rd5vm7si4o 8 месяцев назад

      before we already pump down out the oil in the evaporator with its r134a , drain all the r134a and the oil in evaporator side

  • @Ariff-zt2gc
    @Ariff-zt2gc Год назад

    Hi bro Holden , basically i've experiencing quite a number of times OIL - VARIABLE SPEED PUMP - DRIVE CONTACTS OPEN FAULT ALARM .
    Checked and verified no voltage across the output . Replaced to a brand new VSOP Board as well but the fault came back again in just 2 months . Any other alternatives or solution on what to check ? Can temporarily bypass somewhere to make the system online ?

    • @southendcycleworks
      @southendcycleworks Год назад

      The VSOP boards lately are not very good quality. They usually come with a 1 year warranty and I've had to use it many times

    • @nellAyaR2034
      @nellAyaR2034 Год назад

      Might want to get the input line inductor for vsop

  • @HVAC-EngineerRam
    @HVAC-EngineerRam Год назад

    Sir what is your language

  • @HVAC-EngineerRam
    @HVAC-EngineerRam Год назад

    I want join this channel in Hindi language

  • @HVAC-EngineerRam
    @HVAC-EngineerRam Год назад

    This video want in Hindi language please share

  • @ahmedabdeldayem8252
    @ahmedabdeldayem8252 Месяц назад

    thanks for your help but please speak slowly 😅