How to connect 2 Downspouts into ONE Main Line - PRO Kit Example PART 2

Поделиться
HTML-код
  • Опубликовано: 25 мар 2024
  • How to connect 2 Downspouts into ONE Main Line
    This is a perfect example of two downspouts wyed together with nice slope on the system. The catch basins are at the perfect distance off the house. Right away we're going to be dumping shingle gravel off the roof. It falls out of the downspout into our FDM's Not Quite a 90 which is ramped and set with a lot of slope. We want to get all that shingle gravel to the inline sediment trap. Now we can run this line as far as we want because we know that we have no contamination in the system.
    💧Order FDM's 3 in. Pro Kit for Buried Downspouts:
    frenchdrainman.com/product/3-...
    💧Shop All Downspout Kits:
    💧Shop All FDM's Drainage Supplies:
    =======
    French Drain Man - Michigan’s Yard Water Drainage Experts. Masters in the art of constructing contained French drain systems & curtain drain systems that and fix your yard drainage problems for years to come. Over 30 years’ experience in solving yard water drainage problems in Oakland, Macomb, Lapeer, and St. Clair Counties.
    French Drain Man / Sherwood Landscape Construction, LLC
    P.O. Box 777
    Almont, MI 48003
    248-505-3065
    www.frenchdrainman.com
    www.macombcountylandscaping.com
    Follow us on:
    Facebook: / frenchdrainmanusa
    Instagram: / frenchdrainman
    How to connect 2 Downspouts into ONE Main Line
    #downspouts #gutters #gutterguards
  • ХоббиХобби

Комментарии • 38

  • @panelpal111
    @panelpal111 2 месяца назад +2

    Very impressive. Your products look awesome

  • @DK85
    @DK85 2 месяца назад +2

    Robert, do you ever tie a sump pump discharge line into a downspout system like this?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад +3

      I typically try to keep them separate so that you don't overwhelm the pipe when you do need that sump pump discharging.
      2 for the price of one. Dig one trench and put 2 pipes in it. Make the most of your sweat equity.

    • @DK85
      @DK85 2 месяца назад

      @@FRENCHDRAINMAN Thank you for the reply!

    • @sean4586
      @sean4586 2 месяца назад +1

      Thanks for asking. This was a question I had also!

  • @ryanyoung6978
    @ryanyoung6978 2 месяца назад +1

    How about connecting down spout to French drain. Thought I seen a video with it but not sure

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад +3

      It's a terrible idea. Fills you perforated pipe with debris and plugs the perforations.
      Don't do it.

  • @tavarisjones551
    @tavarisjones551 2 месяца назад

    It would be great if you mentioned what size roof these 3" drains are handling. I have personally seen rains heavy enough that the pop-up emitters blew off of 4" pipe and there was an actual geyser shooting up from the 4" pipe.

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад +1

      You should stick with 4" and consider not running them together

  • @steveg1054
    @steveg1054 Месяц назад

    Hi Robert. First off, thank you for all the education. I have been glued to your videos this weekend. Question: In some of your videos I see tie-in of surface drains into the same downspout drains. Can I tie-in 2 downspouts as well as 1 or 2 surface grates into the same 3" pipe or would you go 4" in that case? Also, I see a frenchdrainman in Canada and wanted to make sure they are associated with you? Thanks! - Steve in Ottawa

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  Месяц назад +1

      Yes, French Drain Man Canada is a wonderful distributor. Mike has done an amazing job. I would go with 4 inches if you are tying in surface drains.

  • @myronnisiewicz5448
    @myronnisiewicz5448 2 месяца назад +1

    I just bought 4 of these kits but now realized that i want to t 2 together. Is the 3 inch y fitting special for this plus size pipe? Do you sell it?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад

      frenchdrainman.com/product/3-in-corrugated-wye/

  • @I_AM_HUGO
    @I_AM_HUGO 2 месяца назад +1

    How deep is the frost line in Michigan? I'm in Wyoming. I don't know if I can go deep enough to keep from freezing. Will I have to use heat trace regardless? Also, is this new kit as good as the blue stuff you sell? I don't want to install this and have it crack in a couple of years. Thanks!!!

    • @latinoluis1
      @latinoluis1 2 месяца назад +1

      I believe depth doesnt matter as long as its pitched well enough that no water stays inside in winter to freeze. Someone correct if im wrong.

    • @baxt1412
      @baxt1412 2 месяца назад +1

      @@latinoluis1 makes sense to me! The whole point is to get the water away from the house. There is an insignificant amount of water that would be held in an individual rib of the corrugated pipe. Then the water gets to the pop-up emitter and either comes out to the surface or will disperse into the subsoil. If there are holes in the bottom of the pop up, emitter

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад

      ruclips.net/video/1kPHHnDc1ZY/видео.htmlsi=TH032XXg4sKcoCnJ

  • @mr.green7323
    @mr.green7323 Месяц назад +1

    What are your thoughts on connecting 3 downspouts to just one 3 inch line? Or is the limit only 2 downspouts for one 3 inch line?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  Месяц назад +2

      If you connect three downspouts to a three-inch line, that would be a liability. You can put two downspouts together if it's on a two by three downspout. If it's on a three by four downspout, just run each one separately. These are the guidelines that we install by.

  • @Odin31b
    @Odin31b 19 дней назад

    Can I connect 5 gutters to 1 line out to the yard like a leaching line?

  • @ktm3850
    @ktm3850 10 дней назад

    How deep is your corrugated for the NE region where there is thaw and freeze cycles?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  10 дней назад +1

      If you build your drainage system correctly, you shouldn't have to worry about the water freezing because no water should be left in the line. We are shallow. It's not realistic to get below the frost unless you're going to a city storm drain or you're going to run it to a pump station.

    • @ktm3850
      @ktm3850 9 дней назад

      ​@FRENCHDRAINMAN Awesome product, designed and engineered very well. I got some projects in the future, and I will invest in these products. I have a bigger problem to tackle first. Slow moving water to drywell in front of the house. I'm guessing sediment clog.

  • @baxt1412
    @baxt1412 2 месяца назад

    Is the pro series being sold online?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад

      Yes.
      3 in. Buried Underground Downspout Premium PRO Kit
      frenchdrainman.com/product/3-in-pro-kit-for-buried-downspouts/

    • @jfischer5392
      @jfischer5392 2 месяца назад

      What's the difference in pipe - high octane blue vs the white pro in the kits? Is the white just easier to work with as a diy-er?

    • @baxt1412
      @baxt1412 2 месяца назад

      @@jfischer5392 good question I’d also be interested

  • @michellejackson9289
    @michellejackson9289 2 месяца назад

    I desperately need this installed in my yard. Do you have anyone in the 63034 area that could install this?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад

      Call our main office to find out they would know 248-505-3065

  • @vvin4746
    @vvin4746 2 месяца назад +1

    Why the 4 inch riser? Why not make a leaf guard that connects to a 3 inch riser and 90?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад

      Yes, we have that, too
      ruclips.net/video/mDlWmcZ-pcw/видео.htmlsi=AkUC0oRFTBOvtX3Q
      3 in. Buried Underground Downspout Kit for DIYers
      frenchdrainman.com/product/3-in-buried-downspout-kit/

    • @vvin4746
      @vvin4746 2 месяца назад

      @@FRENCHDRAINMAN you’re website link says “This has a 4″ 90 degree elbow for easy cleanout. If you need a riser, you will need a 4″ Riser.”
      Again, highly interested in not mixing 4” parts (riser and elbow) with a fully 3” system.

  • @Bear_83
    @Bear_83 2 месяца назад +1

    What the use of a pop up. Is it because you cant get the flow to the road? How many " or ' u start to continue a down slop with 3" piping?

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад +1

      ruclips.net/p/PLjFCqaZ4v1BXt8vDpjMmvJXxMn8Tgw0wA&si=OHJW6YAuVR13XZoq

  • @jamestribol1434
    @jamestribol1434 2 месяца назад

    I bought the kit but it did not have the tape...do I need the tape??? and if so, what is it called? thx

    • @FRENCHDRAINMAN
      @FRENCHDRAINMAN  2 месяца назад +1

      4 in. x 108 ft. FDM's 200 Year Tape - Extra Sticky & Extra Stretchy - French Drain Systems | Curtain Drains | Macomb, Oakland, Lapeer, St. Clair County
      frenchdrainman.com/product/4-x-108-fdms-200-year-tape/