ANALYSING GAS APPLIANCES, how to flue gas analyse all gas appliances and understand your results.

Поделиться
HTML-код
  • Опубликовано: 15 май 2024
  • Derek has combined his 3 part series on how to use a flue gas analyser and understand the results into one video to make it easier for training. If you want to see the full versions check them out on our RUclips channel.

Комментарии • 73

  • @jamesbraithwaite708
    @jamesbraithwaite708 3 года назад +2

    Love these great for brushing up and refreshing the old memory at 30 🤣

  • @helendavies923
    @helendavies923 3 года назад +1

    Really thorough and informative. Thanks, Derek!

  • @naturelover_9211
    @naturelover_9211 3 года назад

    One more great video thank you Derek.

  • @monikanader9454
    @monikanader9454 3 года назад

    Great video, very informative. Thanks Derek 👍👍👍

  • @brenndonherbert4583
    @brenndonherbert4583 2 года назад

    Brilliant video as always. Thanks for the amount of depth that you went into, gained a great amount of knowledge from that.

  • @michaelrose5040
    @michaelrose5040 3 года назад

    Great video really helpful for my ACS
    Thanks Derek

  • @mj0n4id36
    @mj0n4id36 3 года назад

    Nice explanations! First time I’ve seen someone actually flue gas analyse and explain the importance of doing so for other appliances too. Not just for combi boilers. Sweep test always seemed awkward for me but now having watching this video it has really helped. Thanks Derek 👍🏻.
    Asian Jon. Training.

  • @rivkiroyde4362
    @rivkiroyde4362 3 года назад

    Thanks Derek great video👍👍👍👍. Benny

  • @jockster5525
    @jockster5525 2 года назад

    Quality mate really useful video as are all your videos .. absolute star 🌟

  • @ryandow3954
    @ryandow3954 3 года назад

    Brilliant video!

  • @albyhendriks4024
    @albyhendriks4024 Год назад

    Great information

  • @frankdunham6051
    @frankdunham6051 3 года назад +2

    Hi Derek, I started doing my domestic gas at the start of this month and your videos are really helping me consolidate what I'm learning. Really good explanations and detail, keep up the good work, you're helping lots of people out there.

  • @samchappell233
    @samchappell233 2 года назад

    👍👍👍 great video!

  • @darrenclarke161
    @darrenclarke161 3 года назад

    Great info 👏👏👍

  • @paulmilton6123
    @paulmilton6123 3 года назад

    Thanks great video's 👍👍

  • @lostinthoughtscalminsilenc8167
    @lostinthoughtscalminsilenc8167 3 года назад

    Great video

  • @paulrossiter9567
    @paulrossiter9567 3 года назад

    Brilliant video , thanks very much for the in depth recap.
    I don’t like my Kane anymore after seeing yours 😂

  • @dagnallcadarngaming7413
    @dagnallcadarngaming7413 2 года назад

    Great video. Can I ask where the flue integrity readings you quoted are found as in what documents please as I’m struggling. Thanks in advance.

  • @abchannel3737
    @abchannel3737 3 года назад

    You are the best

  • @oneloveonelifeman
    @oneloveonelifeman 3 года назад

    Missing been down the center. Hopefully there soon!

  • @garlic1558
    @garlic1558 3 года назад

    Very good 👍

  • @whome5810
    @whome5810 2 года назад

    How long would the exhaust sample point have to be open to give higher CO readings in the room. Ie 50pp? Does how long this can be left open vary from boiler to boiler? It appeared that you left the exhaust sample point open while you were testing the air intake side, would this not raise levels of CO in the room? Anyway, great video!

  • @raisapotoroaca4016
    @raisapotoroaca4016 3 года назад

    Morning Derek following your pipe bending tutorials do you think you can do some videos about pipe sizing as well
    It will be lovely to see how to measure correctly if it’s possible.
    Thank you very much and please stay safe!!!

  • @qmob0121
    @qmob0121 6 месяцев назад

    Hotly would you test a top oven/ grill combi grill side ? In the same way you do the ovens or is there a another way to use the 7 hole probe to do it ?

  • @dimitardimitrov3300
    @dimitardimitrov3300 2 года назад

    Hi Derek. You are high level teacher and your way to teach is great. You speak so calm and friendly. We all appreciate this. Your videos helped me to improve my knowledge and understanding for my initial ACS. But on my ACS(which I still need to complete) they asked me to gas analyze the cooker hobs and they insist to go and do it. I needed to fill in the readings in the paper too. What will you advice me in this case. I light up the four hobs and hold the analyzer about 30 cm over but I wasn't sure if I do the things correct. Thank you so much! Appreciate all your hard work to teach us!!!

    • @tomkatgastraining
      @tomkatgastraining  2 года назад +1

      You don’t analyser the hobs on a cooker just the oven and grill separately. Not sure why they have asked you to do this as it’s not required unless you are carrying out a room test.

    • @dimitardimitrov3300
      @dimitardimitrov3300 2 года назад +1

      @@tomkatgastraining You are such a good man. Thanks for your help 🙏❤️

  • @farobenz6144
    @farobenz6144 3 года назад

    Hi
    What do they mean by initial and final combustion?
    Thanks

  • @vladimirstafasani4630
    @vladimirstafasani4630 3 года назад

    Excellent video love it.
    Is dynamic pressure same as inlet pressure or working pressure in the boiler?
    Thank you Derek

    • @tomkatgastraining
      @tomkatgastraining  3 года назад +1

      Benchmark seams to have changed max pressure to dynamic pressure so I guess so 👍🏻

    • @vladimirstafasani4630
      @vladimirstafasani4630 3 года назад +1

      @@tomkatgastraining many thanks 👍

  • @Zinadene69
    @Zinadene69 3 года назад

    Hi Derek,
    I see you have shown how to test an inset gas fire, where you need the extension on the probe.
    What I would like to know is, are you able to demonstrate how to analyse a High Efficiency (HE) Inset Gas Fire, which come with a sealed glass front?
    (PS Great videos. Very helpful and informative)
    Stay safe

  • @bernardgatdula9094
    @bernardgatdula9094 2 года назад

    One day please discuss about the electrical system of Bosch Gas Range Thank you.

  • @sanjit41
    @sanjit41 3 года назад

    Great one again,are you going to make video about flue/chimney?

  • @ChelseaFC190512
    @ChelseaFC190512 Год назад

    If there's no MIs like the older boilers then what do you refer too

  • @dkaloupis75
    @dkaloupis75 Год назад

    Procombi Exclusive 24 there is no chance to adjust the minimum or high settings. Any advice on that?

  • @aaronjoyce1980
    @aaronjoyce1980 3 года назад

    Watched Aaron trainee 😁👍👍

  • @ianferguson8367
    @ianferguson8367 3 года назад

    brillant

  • @zaygoodfellowofficial
    @zaygoodfellowofficial 3 года назад +1

    Informative
    Muhammad Faisal Abbasi

  • @saheedk1
    @saheedk1 2 года назад

    I love u so much

  • @darrensworkshop6783
    @darrensworkshop6783 Месяц назад

    Hi Derek Do you have the facility to demo commercial kitchen appliances eg COMCAT1,3 and 5 and carry out a proper CP42 test? I teach this within my company but each engineer has their own way ....I teach using DW172 and IGEM/UP/19 standards.

    • @tomkatgastraining
      @tomkatgastraining  Месяц назад +1

      Sorry mate we don’t have commercial kitchen at tomkat 😢

  • @RahulSingh-jn7py
    @RahulSingh-jn7py Год назад

    Does any one know the ratio of the open flued back boiler as in what it is and where i can find it?

  • @suheilhanna873
    @suheilhanna873 3 года назад

    Such an educational, 53CO 0.0006 ratio.
    is that normal on high setting, I thought CO should be below 30ppm . ratio 0.0004 or under?? .. Still training ...😊... you are a 5 💫💫💫💫💫

    • @tomkatgastraining
      @tomkatgastraining  3 года назад

      For boilers your co could be up to 350 ppm and co2 of up to 10 .2 and a ratio of less than 0.004 depending on the boiler.

  • @faroyoussef1757
    @faroyoussef1757 Год назад

    Sweep test with cover on ? Or cover off?

    • @tomkatgastraining
      @tomkatgastraining  Год назад +1

      Sweep test is testing the covers seals so the cover has to be on

  • @l3thal356
    @l3thal356 3 года назад

    Anyone know the best place to put a flue gas analyser probe on an openflue boiler?

    • @tomkatgastraining
      @tomkatgastraining  3 года назад

      Watch my other videos on analysing and you will find out 😜

  • @marvindallen8916
    @marvindallen8916 Год назад

    👍🏾

  • @asbestosflake5749
    @asbestosflake5749 2 года назад

    Do same video but on a Worcester green star please.

  • @joaovittoria2533
    @joaovittoria2533 2 года назад

    👍👍

  • @natugrmaxion8337
    @natugrmaxion8337 3 года назад

    👍

  • @mervinpermalloo8589
    @mervinpermalloo8589 11 месяцев назад

    🙏👍

  • @craighurst3599
    @craighurst3599 3 года назад

    CH 👍

  • @jon-paulward4580
    @jon-paulward4580 Год назад

    Jon-Paul Ward

  • @secondchance4498
    @secondchance4498 3 года назад

    chris Taylor

  • @gtroadster8035
    @gtroadster8035 3 года назад +1

    Isn’t oxygen 20.9?

    • @tomkatgastraining
      @tomkatgastraining  3 года назад +1

      In the atmosphere yes but on flue integrity we are looking for readings higher than 20.6 o2 and less than 0.2 co2 to prove the flue is ok

    • @gtroadster8035
      @gtroadster8035 3 года назад

      Okay , I’m regards to the flueless fire. I came across a flueless fire with 2 catalytic converters. 1 on each side. How would I test when there is one on each side?

  • @matttate9155
    @matttate9155 2 года назад

    Can you please change the background music in your videos, or better still, just have none.
    It’s pretty much the one and only thing that drives me demented with your videos.
    Other than that, keep them coming!

    • @tomkatgastraining
      @tomkatgastraining  2 года назад

      Not had music in my videos now for over a year 👍🏻

    • @matttate9155
      @matttate9155 2 года назад

      @@tomkatgastraining
      Yeh ok cool. The video I commented on was a year old now I look back though. The xylophone music was pretty awful though! Lol

  • @mgbroadsterJ
    @mgbroadsterJ 8 месяцев назад

    death trap .

  • @Mrcatcherye
    @Mrcatcherye 2 года назад

    no-one in their right mind would bother analyse a LFE fire. Pointless.

  • @andrewturpin1994
    @andrewturpin1994 2 года назад

    You mentioned caravans several times in the video which spiked my interest as this is my trade, would be very interested in seeing these tests done on an a modern oven in a touring caravan or motorhome 🚐

  • @chrisjones4500
    @chrisjones4500 Год назад

    👍👍