Electrical Fault Finding Protective Bonding Conductor to Gas and Water. AM2 and AM2S Assessment

Поделиться
HTML-код
  • Опубликовано: 26 дек 2024

Комментарии • 54

  • @GSHElectrical
    @GSHElectrical  3 года назад +3

    Please add the knowledge from the video below to the one you are currently watching. Thanks Gaz
    Parallel Earth Paths - AM2 and AM2S Removing them for the Continuity of the Protective Bonding Test ruclips.net/video/c2xEoNPfx3s/видео.html

  • @no_short_circuit
    @no_short_circuit 4 года назад +6

    To quote you....."this video has been some help"......keep them coming

  • @richardwhitwam9979
    @richardwhitwam9979 4 года назад +13

    Cool - keep them coming . Fault finding series is a great idea

  • @doctorelectric470
    @doctorelectric470 4 года назад +3

    still interesting, I like to watch these videos still as a registered CPS spark just to make sure that I'm keeping to the required standard, due to my experience I am now pre-empting what you will be doing in each situation.
    Love the videos Gaz & team, see you soon.

  • @leewright4622
    @leewright4622 4 года назад +18

    Thanks for all your training and content, passed my am2s first time last week with 98%

    • @GSHElectrical
      @GSHElectrical  4 года назад +1

      Lee that’s amazing great work 👍

    • @matthewdale956
      @matthewdale956 4 года назад +1

      Well done 👍

    • @donovangreenwood69
      @donovangreenwood69 4 года назад

      What did you find the most difficult

    • @leewright4622
      @leewright4622 4 года назад +1

      Donovan Greenwood id say the conduit bending was the most awkward as you have to be so accurate with it. GSH channel has some good videos and tips which helped a lot before hand.

  • @efixx
    @efixx 4 года назад +2

    Wow another amazing free video for the apprentice of the electrical industry 👍. Great work Marcus

  • @GunnyRabbit
    @GunnyRabbit 4 года назад +13

    Looking forward to this series of vids.. I love fault finding!!!

  • @matthewdale956
    @matthewdale956 4 года назад +1

    Apprentices must love this channel, great work guys

  • @cm0916
    @cm0916 4 года назад +5

    Brilliant your taking the time to make these helpful videos on fault finding 👍

  • @paultipton743
    @paultipton743 4 года назад +4

    I have experienced it in social housing at a property where the tenants were getting a Shock/Tingle off the kitchen sink when washing up( wet hands).The property just had a new kitchen units fitted and the Equipotential water bond was not reconnected and behind the units out of site( had to use a r2 wander lead to check if pipes were earthed ) and also it was a TT supply with the main earth cable had become disconnected inside the earth rod box cover as they weren't properly clamped and just had wires splayed with no clamp both were tested using a r2 wander lead and checking Ze at the consumer unit . so basically no main Earth as well for possibly many years relying on just the water Equipotential bond. It was corrected on both issues with testing carried out.

  • @JoeRobinsonTraining
    @JoeRobinsonTraining 4 года назад +4

    Fault finding master Marcus! Woop-woop!

  • @Spin_or_dive
    @Spin_or_dive 4 года назад +6

    Always very helpful cheers lads!!

    • @GSHElectrical
      @GSHElectrical  4 года назад +1

      Thanks for the support. Marcus 👍

  • @kangtheconqueror
    @kangtheconqueror 4 года назад +1

    Excellent. As a relative newbie to the industry I've always found fault finding to be the most difficult aspect of the job... not to mention the most frustrating.
    Looking forward to getting to grips with these issues. 👍🏼

  • @benjibiker6053
    @benjibiker6053 4 года назад +5

    Love it, straight to the point 👍👍

  • @kobeyossef5903
    @kobeyossef5903 4 года назад +2

    keep them coming I love fault finding Thanks

  • @hasanucar5456
    @hasanucar5456 4 года назад

    I’m not in even this industry but love looking at these videos. if they did a basics series for beginners would really appreciate it.

  • @thomasbyles3075
    @thomasbyles3075 4 года назад +1

    Loving this video, looking forward to the next

  • @wallbouncer9655
    @wallbouncer9655 4 года назад +3

    Great work Marcus 👍

  • @georgeweston9024
    @georgeweston9024 3 года назад +1

    I just recently passed my am2s assessment and want to say thanks. Your videos were very helpful in my preparation.

  • @aranfairozi1331
    @aranfairozi1331 Год назад +1

    Honestly you lot are so useful thank you 💐

    • @GSHElectrical
      @GSHElectrical  Год назад

      Thanks for the fantastic feedback 👍🏻

  • @jassingh4722
    @jassingh4722 Год назад

    Hi, do you have any more other videos on fault finding for the am2s.
    Faults on: bonding, heating system, DOL, lighting and light switches and sockets

  • @DK-ot1to
    @DK-ot1to 4 года назад +1

    I love your videos Gaz (and Marcus), really helpful and informative! Just a quick question regarding bonding. If we have a mixture of copper and plastic pipe, how is the best way to bond the copper? Do I have to go from section to section with the bonding to ensure continuity?

  • @gabeerlazem7798
    @gabeerlazem7798 4 года назад +4

    Thank you 🙏

  • @mking733
    @mking733 10 месяцев назад

    What type of fault would this come under? Would it be an open circuit?

  • @MrKwelsh
    @MrKwelsh 4 года назад +1

    Would there not be 2 faults here? One causing the tingling, a line conductor possibly touching the pipe and also the fact it's not tripped the RCD,which is showing the broken bond as youse pointed out?

    • @MrKwelsh
      @MrKwelsh 4 года назад

      No cheek intended by the way , always learning myself.

    • @adamparkin4791
      @adamparkin4791 4 года назад +1

      I was thinking exactly the same lol

    • @londontrada
      @londontrada 4 года назад

      Its just a potential difference would be a tiny, naturally occuring voltage

  • @jamesgledhill9667
    @jamesgledhill9667 4 года назад

    Under what circumstances would a tingle accur anyway. After you bond should you investigate how there is voltage on the pipe?

    • @londontrada
      @londontrada 4 года назад

      Its just a potential difference would be a tiny, naturally occuring voltage

  • @SteveLondon88
    @SteveLondon88 4 года назад

    New to being an electrician and haven't done any fault finding so far so these videos are greatly appreciated. One thing I didnt understand was how someone would be getting a slight shock off the pipe?

    • @msp2896
      @msp2896 2 года назад

      Under fault conditions, everything that is earthed becomes the same potential. For example 50v. All pipework, metal clad sockets, fridge freezer etc become 50v on the extraneous/ exposed conductive part. When the bonding is broken, the gas pipe will no longer be at the same potential as the rest of the installation so if you touched the fridge freezer (50v fault condition) and the gas pipe (0v) at the same time then the potential difference is 50v going through you. If the gas pipe was bonded there would be no potential difference therefore no shock/ current flow. 50v from fridge to 50v to gas pipe = 0v

  • @nomadicsoul34
    @nomadicsoul34 3 года назад

    Apologies but what is causing the tingle? Where is the voltage coming from?

  • @ishkebab
    @ishkebab 4 года назад +3

    Excellent training video again but to nit pick , There is no maximum reading of 0.05 ohms for a main protective bonding conductor given in the regulations, they are sized to table 54.8 or where non pme conditions exist, half the size required of the earthing conductor etc etc. Even gn3 states that the 0.05 reading is NOT from the MET to the extraneous pipework, it is just a general low number of resistance to confirm that pipework when tested between one another is reliably connected together by a suitably low resistance say ‘0.05 ohms’

    • @GSHElectrical
      @GSHElectrical  4 года назад +2

      Remember the level of learners we are teaching : level 1, 2 and 3.
      A reading ideally around 0.05 ohms - measured between any two metallic parts - is usually considered adequate to confirm that bonding is in place...
      Hence if you have a reading to both gas and water of 0.05 ohms over less the reading between them should be 0.05 ohms or less... we go into more detail in the classroom at level 3 and 4.
      Fantastic comment and thanks for watching. 👍

  • @robswingler
    @robswingler 4 года назад +1

    The 0.05 ohms doesn’t actually appear in the regs . It only appears in one of the guidance notes.

    • @GSHElectrical
      @GSHElectrical  4 года назад

      Thanks see other comments for think on 0.05 ohm 👍 Gaz
      PS remember the level of learners.
      Thanks for watching and commenting. GAZ

  • @jamiereardon8118
    @jamiereardon8118 4 года назад +4

    😂 How many videos of fault finding can use get up before i take my fault finding section on Wednesday 😅

  • @seandempsey7351
    @seandempsey7351 2 года назад

    What is happening with my posts they seem to be hidden blocked or deleted?

    • @GSHElectrical
      @GSHElectrical  2 года назад +1

      Unlikely Sean - repost your comment 👍🏻