Relay Setting in Star Delta Starter | Star Delta Starter relay rating

Поделиться
HTML-код
  • Опубликовано: 13 окт 2024
  • Queries solved:
    1. What is star Delta starter.
    2. What is star Delta starting.
    3. How to select relay for star Delta Starter.
    4. Relay rating Selection.
    5. Relay Selection guide.
    6. Star Delta Starter relay Selection.
    Hello Friends in this video we discussed about how to select relay for star Delta Starter in the simplest way possible.
    About Channel:
    In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
    #StarDelta
    #Relay
    Kindly subscribe.
    Thank you.

Комментарии • 132

  • @rajnipatel445
    @rajnipatel445 2 месяца назад

    Good morning sir stardalta motor relay line current me Laguna better he ki phes current me better he

  • @pawansoni1165
    @pawansoni1165 2 года назад

    Sir Star ki condition me bhi bataiye and DOL Starter ke Case me bhi suggest kijiye

  • @skdoniya2003
    @skdoniya2003 2 года назад

    Sir 2pole or 4pole olr setting same hai?

  • @PappuSingh-em2ve
    @PappuSingh-em2ve 2 года назад

    Please tell me in star delta starter olr setting will be different or not and will be then how much for star and delta

  • @Hemanth2787
    @Hemanth2787 4 года назад +2

    Is fullload current is same in star conncetd motor and delta connected motor for same kw rating?

  • @jayendraahir1312
    @jayendraahir1312 2 года назад

    Sir 90 kw motor ka fhul load curent 158 amp he .motor runinig continou to rely setings delta current me hi set hogi 158 amp

  • @RajeevSainielectricals
    @RajeevSainielectricals 3 года назад

    Very good f
    sir I'm ur fan...

  • @thakornj9493
    @thakornj9493 2 месяца назад

    Star delta me 6 wire hote he relay main contactor me lagta he to current to 2 bhag me bat jaata he to kya kare....50A motor ka rated current he star delta connection or relay main cont.me laga he 50A tak set karna ho to 25 A par set kare ya 50 A..????

  • @alijee4876
    @alijee4876 2 года назад

    Good Sir i appreciate from Pakistan

  • @ShaoibKhanDiaries
    @ShaoibKhanDiaries 2 месяца назад

    Very nice

  • @Adren0.
    @Adren0. Год назад

    What if in DOL starter motor winding is delta in that case also we set O/L to 58% of Full load current

  • @hasmukhpiprottar17
    @hasmukhpiprottar17 2 года назад

    sir mere pas 75kw ka motar he or ishame main mpcb 400A ka or sir over load relay face current me laga or muje ae motar daily start stop karna he sir inka relay seting 58% 74.5A pe rakhata hu to starting mehi motar over load ho jata he

  • @vishalpatel-fe1yd
    @vishalpatel-fe1yd 4 года назад

    Sir 90kw ki motor ka current kam hota he na 160 amp something

  • @ravishankarsharma5315
    @ravishankarsharma5315 2 года назад

    For 20 HP, 3 Phase Induction Motor of Submersible Pump, which starter we have to select - 20 HP or 22.5 HP and what will be selection criteria & How ?
    Pls reply.

  • @suryakantyadav128
    @suryakantyadav128 4 года назад

    Sir mere Ghar me 7.5 kw ka motor hai Jo ki manul star Delta starter say chal rha tha ,per kuch deno say usme proble aa rha tha ,contect melt ho gye the aor coil bhi hold nhi ho rha tha,to Maine usme mody fykr diya hu ,uske andar 32Amp ka MCB ,,32Amp ka contector aor 20Amp max range ka OLR really install kr ke DOL STARTE me convert kr diya hu ,relay setting 13 Amp me kiya hu ,Kyo ki sir Ghar me mai any time rhta nhi hu aor baaki log non technical hai setting Kam krne per baar baar trip hoga ,es say agar Ghar ke log rest krne jyeng to electrical hazard ke chanses bad jyenge,, to sir Maine sahi Kiya ya galat (selection of breakers/Relay

  • @abhijitdutta244
    @abhijitdutta244 4 года назад +2

    Sir je please RMU ar alternator ka ak alag si video banaia 🙏 🙏 🙏🙏

  • @vinun9307
    @vinun9307 3 года назад

    I love your all electric videos. Very usefull
    Plz muze apke electric groip me add kardo

  • @chandrakantapradhan4963
    @chandrakantapradhan4963 Год назад

    Awesome 👍

  • @Electricalengineering-sx1yq
    @Electricalengineering-sx1yq 3 года назад

    Good video

  • @VinaySingh-qy4ip
    @VinaySingh-qy4ip 3 месяца назад

    Nice

  • @sidharthpatil8416
    @sidharthpatil8416 3 года назад +1

    3phase / 1 phase motor ka winding restiance kitana hona chahiye , short winding kase pata kare, multimeter ke kaise check kare..... please support

  • @dilipsahusahu680
    @dilipsahusahu680 4 года назад

    Very nice explain sir aapka video acch Lagta hai

  • @SandeepSharma-xy3oj
    @SandeepSharma-xy3oj 4 года назад +1

    Thanks sir,
    In your video say drow current in stat only 33% how? Plz explain me.

  • @SanjayChauhan-dz4cw
    @SanjayChauhan-dz4cw 4 года назад

    For star delta starter thermal over load relay range selection is 80% for min range and 120% for max range formula applied ?

  • @balkumarchauhan7756
    @balkumarchauhan7756 Год назад +1

    Pichhle video me star connections motor adhik current leti hai delta connections ke dikhaya hai sir
    Aur yha pr Star 33% aur delta 58% current leti hai full load current ke kaise

  • @anildarri2185
    @anildarri2185 2 года назад

    Nice explain sir

  • @cricguruinfo1938
    @cricguruinfo1938 3 года назад

    Sir plc ke uper video banaye

  • @sanjayajena6711
    @sanjayajena6711 3 года назад +1

    Thank you

  • @AlishaKhan-ld2qt
    @AlishaKhan-ld2qt 2 года назад

    Nice sir

  • @Rajeevkumar-ri7oz
    @Rajeevkumar-ri7oz 3 года назад +1

    Nice information sir ji

  • @mddanish-zk7xn
    @mddanish-zk7xn 29 дней назад

    Thanks sir

  • @siyaramrathore6722
    @siyaramrathore6722 2 года назад

    Sir agar normal motor ko delta me connection karte hain to FLC Ka 80% use karte hain
    Aur Star to Delta me 58 % hi kyu
    Kyuki Delta ka formula Dono condition me same hi rahta hai
    As Line Current = √3 phase current

  • @kamtaprasad784
    @kamtaprasad784 4 года назад +1

    Fantastic video 👌👌
    Thanks sir 🙏

  • @hiteshwarsingh9685
    @hiteshwarsingh9685 4 года назад +1

    Sir star delta starter me really men contrecror ke output me laga hota hai usme moter ke 3 terminal, baki 3 terminal delta contrecror me to Mera confusion ye hai ampiar kese check hoga moter ka

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Hiteshwar, motor mein jo 6 lead ja rahe hai (3 main contactor se aur 3 delta contactor se) usme current check karo..

    • @hiteshwarsingh9685
      @hiteshwarsingh9685 4 года назад +1

      @@electricalwithabhishekjoshi sir Mera cunfusin ye hai really se 3 terminal baki 3 delta se to really actual current sens kese Karega kya really Ka position tik hai ya mccb brekar ke bad olr really lagana chahiye olr really Ka sahi position kya hona chahiye

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Hiteshwar relay ka position sahi hai... 6 leads mein same current hi flow hota hai..

    • @hiteshwarsingh9685
      @hiteshwarsingh9685 4 года назад

      @@electricalwithabhishekjoshi really 90amp me set hoga to really ke output R our delta contrecror ke output R phase me kitne Amp par trip hoga us time. dono R phase me Kitna amper bahega

  • @shahidqadri4340
    @shahidqadri4340 3 года назад

    Abhishek,
    Kindly make a video on star to delta shifting time as per motor capacity.

  • @Hemanth2787
    @Hemanth2787 4 года назад +1

    .what will be the line current of 5kw motor if it s conntected in star nd what will be the current in delta if tha same motor s connted and connection are changed

  • @ahirvijaykumar7576
    @ahirvijaykumar7576 2 года назад

    Sir star delta starter se chalne Vali motor ka flc kese nikale

  • @suryakantyadav128
    @suryakantyadav128 4 года назад

    Nice explation sir,

  • @AshisNayak-cs5hc
    @AshisNayak-cs5hc 4 месяца назад

    If star delta starter power on without any load then what happen?

  • @rashmiranjandalai9054
    @rashmiranjandalai9054 3 года назад

    Sir kindly reply me what is iph

  • @BrajeshPathak-e8i
    @BrajeshPathak-e8i 5 месяцев назад

    Thanks❤❤❤ sir

  • @ErUttamGupta
    @ErUttamGupta 2 года назад

    BUT if we used DMPR or OLR just after the MCCB then wiring the star , delta and main contactor tab to 80% rakhna parega na sir

    • @kavyasingh815
      @kavyasingh815 Год назад

      Yes

    • @ErUttamGupta
      @ErUttamGupta Год назад

      @@kavyasingh815 Are u experienced or fresher ?

    • @kavyasingh815
      @kavyasingh815 Год назад

      I have one year experience
      I saw a video on these topic electrical dost channel

    • @ErUttamGupta
      @ErUttamGupta Год назад +1

      @@kavyasingh815 Oh , i also have 4 years of experience.

    • @kavyasingh815
      @kavyasingh815 Год назад +1

      Great

  • @mbkelectricals6649
    @mbkelectricals6649 4 года назад +1

    Great work sir 👍👍👍

  • @randheerpatel7414
    @randheerpatel7414 Год назад

    Thanks bro

  • @pawanrathod1408
    @pawanrathod1408 3 года назад

    Sir continuity kya hota hai electrical mein batayiyena please
    Mein ek biginar huu please Sir batayiyena

  • @kuldeepcheem98
    @kuldeepcheem98 3 месяца назад

    Thanks

  • @samvedna22
    @samvedna22 4 года назад +1

    Awesome videoo

  • @iftikharahmed1670
    @iftikharahmed1670 3 года назад

    Good one thank u so much

  • @suvendukar7947
    @suvendukar7947 4 года назад

    Thanks Abhishek

  • @CulturalyCurious
    @CulturalyCurious 4 года назад +1

    Awesome video 👍👍👍

  • @ankitkd6003
    @ankitkd6003 3 года назад

    Pl suggest how to set time range of star delta timer

  • @NazrulIslam85
    @NazrulIslam85 3 года назад

    Great great great great

  • @d.kkumar4186
    @d.kkumar4186 4 года назад +1

    Nice video sir

  • @tegbahadur6790
    @tegbahadur6790 3 года назад

    Good knowledge thank you sir

  • @satishvarma3346
    @satishvarma3346 3 года назад +1

    In Star delta star timer setting for star to deta change over time plzz

  • @mitubarik3361
    @mitubarik3361 3 года назад

    But sir there are 1OLR in star delta srater how i can change OLR seeting in star 33% and delta 58%

  • @thanikanikaran
    @thanikanikaran 3 года назад

    Nice mes 👍

  • @suryakantyadav128
    @suryakantyadav128 4 года назад

    Sir lag rha hai ye Corona job kha jyegi

  • @sumits_shetty
    @sumits_shetty 3 месяца назад

    Ap 58% of FLC bol rahe ho. Ye obviously Iph hoga na?
    Over load relay Phase me lagaya to hi ye apply hoga.
    Incase line me over load lagaya to full load ampere set Krna hoga

  • @d.kkumar4186
    @d.kkumar4186 3 года назад

    Mpcb 400amp ki sating kse kre

  • @mayanksammal4378
    @mayanksammal4378 3 года назад

    Thanku sir ♥️

  • @gunvantgotmare7515
    @gunvantgotmare7515 9 месяцев назад

    Kw se kitaneka relay lagasakate

  • @niteshkumar1738
    @niteshkumar1738 4 года назад +1

    How to calculate Amp. in star delta drive , as it have 6 wire connection ?

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Nitesh, are you talking about Full load current??

    • @niteshkumar1738
      @niteshkumar1738 4 года назад +1

      @@electricalwithabhishekjoshi Yes Sir

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Nitesh Maine star Delta starter ka full load current pe video banaya hai. Aap wo dekh sakte hai.

    • @niteshkumar1738
      @niteshkumar1738 4 года назад +2

      @@electricalwithabhishekjoshi sir i already watch that video,but matter is not clear to me.
      Suppose 250kw motor is running with star delta and i have to take full load current with "tounge tester ", how i will calculate full load , as star delta have 6 nos. of lead ?

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Nitesh the current you take with fluke meter is running current not a full load current. All the 6 lead draw same amount of current. But that current is a running current.

  • @Aaru-Angel
    @Aaru-Angel 3 года назад +2

    90 kw motor sir 156 amp legi....ok

  • @d.kkumar4186
    @d.kkumar4186 3 года назад

    3RB2283-4AA1 RELAY PR AK VIDEO BNAO SIR

  • @manojkhilar4540
    @manojkhilar4540 3 года назад

    sir star delta starter phase relay setting,please clearly

  • @babasahebgondhali7719
    @babasahebgondhali7719 4 года назад +1

    Sir 90kw motor ka full load current 160amp hotahe

    • @ZYXYZLF
      @ZYXYZLF 2 года назад

      It's depend on PF and Efficiency

  • @sumanghosh3298
    @sumanghosh3298 4 года назад

    Vai 90 kw motor me FLC current 180amp? Kaise?

    • @satyamjaiswal5561
      @satyamjaiswal5561 3 года назад

      90÷.746=121hp then, 121 *1.5= 180 amps

    • @sumanghosh3298
      @sumanghosh3298 3 года назад

      @@satyamjaiswal5561 vai not 1.5 tum is formula ko savi motor me apply nahi kar sakte . Kuki motor ka PF or uski efficiency vi depends karti he us motor ki FLC ke upar.

    • @sumanghosh3298
      @sumanghosh3298 3 года назад

      Max current I =power/ √3×V×cos¢×effeciency
      Tum total power of motor / 500 To 550 se devide karoge to near about result milega.

    • @sumanghosh3298
      @sumanghosh3298 3 года назад

      @@satyamjaiswal5561 90KW =90000watt
      90000÷500= 164 amps

    • @itielectricalclasses201
      @itielectricalclasses201 Год назад

      Ye chutiya banate hain

  • @vinodbareth4344
    @vinodbareth4344 4 года назад +1

    Delta full load current 58% kaise hits hai

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      In delta IL=root 3 x Iph hota hai.
      So, Iph = 1/1.732= 57.7
      In Industries we normally take 58 for Calculation

    • @dhaniraikwar7455
      @dhaniraikwar7455 3 года назад

      @@electricalwithabhishekjoshi sir d.o.l starter me bhi to motor runining condition me delta me conect rahti he ....or star delta starter me bhi runing me motor delta conect hoti he ....phir kyo?...80% or 58%....pls expln sir ji

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  3 года назад

      Video banata hu

  • @sureshkumar-fp8bl
    @sureshkumar-fp8bl 2 года назад

    Sir,not add servise factor.

  • @tikendraverma863
    @tikendraverma863 3 года назад

    Sir ब्लैकबोर्ड में समझाओ ना

  • @itielectricalclasses201
    @itielectricalclasses201 Год назад

    सर आपने अपनी वीडियो में 90 किलो वाट का मोटर का फूल लोड करंट 180 amp बताया है
    Aap Aisa Kyun Bata rahe hain

  • @badgujarminesh6776
    @badgujarminesh6776 Год назад

    Where is 58% has come from..I mean how we made the calculation of 58%

  • @rashmiranjandalai9054
    @rashmiranjandalai9054 3 года назад

    Iph kya he

  • @itielectricalclasses201
    @itielectricalclasses201 Год назад

    90 kw motor ka FLC 180 kaise ho jayega sabhi log batao .
    Ek video kuchh aur hote Hain aur dusri video mein kuchh aur bolate.
    Kripya gumrah na Karen😅

  • @travelwithsaikumar
    @travelwithsaikumar 4 года назад +1

    Why only 58%

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      1/1.732 ka percent nikalo.. its 57.7%
      Phase current is 1/1.732 time of line current. Video mein bataya hai.

    • @SandeepSharma-xy3oj
      @SandeepSharma-xy3oj 4 года назад +1

      Sir, Why take only 33% in star. When voltage reduce the current increase.?
      Practically we see when motor starting time current take more the full load. Plz reply..

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  4 года назад

      Sandeep, it is true that when voltage increases current decreases and vice versa. I think you have doubts that voltage will decrease in star then how current will decrease as they are inversely proportional. Right?
      But Sandeep, you are comparing phase voltage with line current.
      In star, phase voltage will reduce not the line voltage.
      Hope you got the point..

    • @SandeepSharma-xy3oj
      @SandeepSharma-xy3oj 4 года назад

      @@electricalwithabhishekjoshi thanks

  • @hemantkumarthakare9563
    @hemantkumarthakare9563 3 года назад +1

    Thank u sir