Which connection is preferred star or Delta| Star Connection vs Delta Connection | Hindi

Поделиться
HTML-код
  • Опубликовано: 28 авг 2024
  • Queries Solved:
    1. What is star Connection.
    2. What is Delta Connection.
    3. Star connected motor.
    4. Delta connected motor.
    5. What is motor Efficiency.
    6. How to improve Power Factor.
    7. How to improve motor Efficiency.
    Hello Friends in this video we discussed about Star Connection and Delta Connection in the simplest way possible.
    About Channel:
    In this Channel we cover the topics like Machines, Power System and General Electrical in the simplest way possible.
    #Star
    #Delta
    Kindly subscribe.
    Thank you.

Комментарии • 142

  • @-BhargavkumarSarma
    @-BhargavkumarSarma 3 года назад +7

    I have watched so many videos with long duration time but never got such amazing explaition within few mins...keep it up sir....i m confident it will hlp me in any interview

  • @AkashSharma-rn4hn
    @AkashSharma-rn4hn 3 года назад +10

    You deserve much more appreciation ♥️

  • @avantikatrivedi2949
    @avantikatrivedi2949 3 года назад +5

    Well Industry experience you have!! And best part is your keep sharing learnings to us..! Thanks you

  • @shyamsahu123
    @shyamsahu123 6 месяцев назад

    Sir, u deserve a standing ovation 👏👏👏 4 ur teaching a good lesson about motors, to my type poor and basic iti electrician students.

  • @dreamcometrue3620
    @dreamcometrue3620 3 года назад +1

    Sir ji tussi great ho👍☺️

  • @samitkumarmallick6191
    @samitkumarmallick6191 Год назад

    Hi sir i am very very satisfied and clear my basic fundamentals of your videos heartly ❤️ thanked

  • @cheyguvera9680
    @cheyguvera9680 2 года назад +1

    One of the best channel so far i have seen for electrical engineering.

  • @deeprajshanker2325
    @deeprajshanker2325 3 года назад +1

    All my doubts are cleared now and please try to make VDO of DG AMF panel .

  • @dipanbarman8716
    @dipanbarman8716 2 года назад +1

    Very explicit explanation.

  • @CulturalyCurious
    @CulturalyCurious 3 года назад +1

    Very important...well Explained 👍👍👍

  • @samvedna22
    @samvedna22 3 года назад +3

    Well explained 👍

  • @maheshkoli6525
    @maheshkoli6525 3 года назад

    Abhishake ji apane bahut achha explanation kiya. Meri ek request hai apase Star aur Delta mai Resistance, Voltage, Current, Power, Power factor, Efficiancy, aur losses kitane hote hai with calculation iska eak video banake explain karoge to bahut achha hoga. Thanks

  • @arunjoshi2089
    @arunjoshi2089 3 года назад +3

    Nicely explained.👍

  • @beautyinnature5366
    @beautyinnature5366 3 года назад +1

    Superb... explanation

  • @ayushkumarnayak752
    @ayushkumarnayak752 2 года назад

    Really very good knowledgeable video thanks your sir.

  • @buddha1529
    @buddha1529 10 месяцев назад

    Thanks nice video 👌

  • @jayendrarathod9999
    @jayendrarathod9999 3 года назад +2

    Tx sir

  • @learnbyshiva725
    @learnbyshiva725 3 года назад +1

    Thanks very much sir

  • @vipinsharma1677
    @vipinsharma1677 3 года назад +1

    Abhishek ji Pump application me i think hum ye nahi kar sakte because apko pumping karna hota he ek particular flow or head ke according pls suggest

  • @HassanAli-bd3rb
    @HassanAli-bd3rb 11 месяцев назад

    ❤❤❤ that's great sir ❤❤❤

  • @shailendrajadon3599
    @shailendrajadon3599 3 года назад +2

    Well explain sir... Keep it up 👌👌

  • @gamingtrials4951
    @gamingtrials4951 8 месяцев назад

    Nice video sir 👍

  • @pramodzate2881
    @pramodzate2881 Год назад

    Superb sir.

  • @BishwajitSwain-bi3pn
    @BishwajitSwain-bi3pn 22 дня назад

    Sir why we run the motor in dol and Rdol reason ? Make a video about this topic sir👏👏

  • @bharatekmauj3245
    @bharatekmauj3245 3 года назад

    Your contents are short and sweet. Keep it on.

  • @injamulhaque9641
    @injamulhaque9641 2 года назад

    1cr Likes for you, very well explained

  • @kamtaprasad784
    @kamtaprasad784 3 года назад +1

    Mind blowing 👍👍

  • @saurabhkanaujia4933
    @saurabhkanaujia4933 2 года назад

    Sir relay ki setting kaise karenge load ke according uspar video bnay

  • @bahadersingh8880
    @bahadersingh8880 Год назад

    Thanks for good information

  • @motivationminds6730
    @motivationminds6730 3 года назад +1

    Hi
    Sir is video mai aapne aakhare mai kaha ki star mai load 1/3 hoga , lakin aapke last video mai delta to star mai current ko underoot 3 se multiply karne se star running current ayega .ye to delta se jyada hai fir power bhi jyada hogi .
    Isse to power badhegi .

    • @anwarhussainansari13
      @anwarhussainansari13 3 года назад +1

      Bhai power badhne Ka ye matalb Nahi ki bahot achhi baat hai wo ab jyada power consumption Kar rahi hai Aisa matalb hai . finally power badhne se electricity jyada kharch Hogi Bhai .

  • @nimeshsk
    @nimeshsk 2 месяца назад

    Do you provide consultancy? Need some guidance on whether rewining motor or buying new and which one

  • @brijesh.vlog..167
    @brijesh.vlog..167 Месяц назад

    Abhishek bhai mines ki exam hain
    ..uske related videos banao

  • @MB-nz9pr
    @MB-nz9pr 2 года назад

    Keep it up.... Bro...

  • @sbpavankadali6520
    @sbpavankadali6520 Месяц назад

    Please explain the protections of C&S CSENEX-I-100 relay in VCB. And how to set the parameters.

  • @sunilnargesh9629
    @sunilnargesh9629 4 месяца назад

    Hi apka new subscriber

  • @lenin123us
    @lenin123us Год назад

    your explaining style is very impressive.
    i have one problem is that i connected one motor in star connection, name plate showing 230/400 ,0.37 kw,0.65 power factor, 2.6/1.5 A,1400 RPM, insulation class F To the vfd drive while it is running at the low setpoint, motor over heating what could be the reason and how to rectify.

  • @HarishKumar-fh1ii
    @HarishKumar-fh1ii Год назад

    Thanks 🎉

  • @g.shivakumar5309
    @g.shivakumar5309 10 месяцев назад

    Super sir

  • @rajeshjadhav00
    @rajeshjadhav00 3 года назад

    Very nice informative video ... 👌👌👌

  • @user-bj1pj8gp4m
    @user-bj1pj8gp4m Месяц назад

    Sir ji Dc motor and starter ka explain kijiye ga

  • @muhammadimranrasheed6863
    @muhammadimranrasheed6863 6 месяцев назад

    Make a video on transformer OLTC internal connection please

  • @PRADEEPKUMAR-cq9pq
    @PRADEEPKUMAR-cq9pq 2 года назад

    MCC AND PCC ke par bhi video bnana sir ji

  • @chandraprakeshmishra4707
    @chandraprakeshmishra4707 9 месяцев назад

    Sir ek video Power facter ke bare

  • @Parihar1986
    @Parihar1986 Год назад

    Sir overload really ko set Karne k liya kis type ka starter use kar rehe h wo dekhna hota h ya motor ka connection kis type ka h wo dekhna hota h

  • @chandrashakhernogia8712
    @chandrashakhernogia8712 Год назад +1

    Sir current injection test of ocr ko explain kijiye na

  • @syedhassnainali2917
    @syedhassnainali2917 3 года назад +1

    Thank you very much

  • @Indianelectricalengineer
    @Indianelectricalengineer 2 года назад

    Bhai eek aur video banaea same topic pr Thora clear kijia concept

  • @shubhamcharde9008
    @shubhamcharde9008 3 года назад +1

    Sir ji aapne bataya ki 15 kw ki motor delta connection se star me ki to oh 5 kw me kaise ho gai ,ho sakta hai 10 kw ki bhe ho sakti hai or relay settings star connection me kaise calculation karke karke kare. Please explain

  • @suryakanth3165
    @suryakanth3165 2 года назад

    Tq

  • @ghulepravin4722
    @ghulepravin4722 3 года назад +1

    Sir please make a video on, why neutral present in star not in delta🙏

  • @TheSiDShow369
    @TheSiDShow369 3 года назад

    Bahut Shandaar😀

  • @faizaerum9699
    @faizaerum9699 3 года назад

    Awsum teacher

  • @surendrakverma555
    @surendrakverma555 3 года назад +1

    Good

  • @bablipanda3145
    @bablipanda3145 Год назад

    Sir Ap Abhi Konsa Power Plant me Kaam kar rahe he .

  • @noorulainansari2699
    @noorulainansari2699 3 года назад +1

    Star or delta connection se metre reading mein kya fark padega

  • @suryakantyadav128
    @suryakantyadav128 3 года назад

    NICE explation sir

  • @PankojGhosh-pk2ic
    @PankojGhosh-pk2ic 6 месяцев назад

    Hello sir VFD mea kon sa motor run karna hota hay star or delta connection motor

  • @divyeshghiwala8502
    @divyeshghiwala8502 3 года назад +1

    Please suggest how energy saving in utilities motors

  • @chandravadanprajapati1601
    @chandravadanprajapati1601 Год назад

    Excellent your every video

  • @Shourya16
    @Shourya16 3 месяца назад

    sir agar single phase to 3 phase vfd se motor connect karana hai to delta connection hi use hota hai na?

  • @yatinpatel6296
    @yatinpatel6296 9 месяцев назад

    Vfd me scaler and vectors control kya hota hai vo thoda dip me samjavo

  • @mrmirza7680
    @mrmirza7680 2 года назад

    Nice explanation

  • @ayushkumarnayak752
    @ayushkumarnayak752 2 года назад

    Sir me abhi Jindal me job kar raha hu please mujhe batayenge kis chiz ke upar dhyan dena hai or kese improve karna he.

  • @RoAbhi45
    @RoAbhi45 3 года назад

    Sr start delta starter ki power wiring aur control wiring ka video banaye

  • @pranay4216
    @pranay4216 Год назад +1

    Motor की efficincy , load के साथ सीधे कैसे संबंधित होती है?????

  • @user-kg8wf3kw2b
    @user-kg8wf3kw2b 8 месяцев назад

    Sir what is delta v?and hazardous area non hazardous area in panel?heat load calculation?fam rpm calculation?

  • @khanstechnical8912
    @khanstechnical8912 3 года назад

    Nice speech.

  • @justicehunt7136
    @justicehunt7136 3 года назад

    Kindly make video on busbar schemes

  • @hiteshpatel4317
    @hiteshpatel4317 Год назад

    40 hp blower application ke under peack load bahot high he 18 second time leta he normal current aane me.
    Starting current reduce krva and Normal current ka time reduce krne ke liye kya kre .

  • @jitendrapal4071
    @jitendrapal4071 8 месяцев назад

    Sir 1 hp ki motor ko adhikatam kitana load pr chala sakte hai

  • @mitubarik3361
    @mitubarik3361 2 года назад +1

    Sir agar 15kw motor delta se star karenge current pabhega hame over size ki relay lagana padega kya?kyun ki 15kw,415v iska current 26A ayega in delta.agar star mein connect karte hai 26A multiply root3 =45Aayega.

  • @sanjeevkumar-el8qi
    @sanjeevkumar-el8qi 2 года назад

    👌

  • @bimalsarkar1768
    @bimalsarkar1768 2 года назад

    Sir star connection me torque jada produce karta he. Load kam condition me delta connection use karna behitar hoga. Delta connection star connection se kam current use karta he operation ke bakth.

  • @manishpatel6828
    @manishpatel6828 2 года назад

    Kitne time k bad motor star to delta me convert hoti he sir

  • @sangamkumar1387
    @sangamkumar1387 3 года назад

    Sir 10 hp ka 3ph moter hai hamko Aata chakki chalana hai star connection ya delta connection karna hoga

  • @natural6086
    @natural6086 Год назад

    Which connection , star or delta is used in star delta startor according to this method ?

  • @mubasshiryunus2241
    @mubasshiryunus2241 Год назад

  • @hiteshpatel4317
    @hiteshpatel4317 Год назад

    Hi sir,.

  • @akshaymore2804
    @akshaymore2804 Год назад

    Rpm me change hoga kya delto to star?

  • @ravishankarkaushal638
    @ravishankarkaushal638 3 года назад +1

    If 1ph 11 kv is disconnected in delta star xmer why 2 ph LT voltage is low and 1 ph is high about 260 volt

  • @aizazrahim8313
    @aizazrahim8313 3 года назад

    Bhai Steel Mills me konnsy motors used hoty hain???

  • @HassanAli-bd3rb
    @HassanAli-bd3rb 11 месяцев назад

    ❤❤❤

  • @YashKumar-hu1xt
    @YashKumar-hu1xt Год назад

    Which connection will cause high Electricity bill?

  • @Shivamkumar-kl1ri
    @Shivamkumar-kl1ri 3 года назад +1

    Sir 3 phase IM ka torque kis pr depend krta hai voltage or current??
    Or star connection me convert krne pr motor capacity 1/3 se kyu reduce ho jati hai?

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  3 года назад +2

      Starting torque voltage pe depend karta hai. But ye bhi yaad rakhiye ki voltage and current khud hi ek dusre se related hai.
      1/3 reduction ki derivation hai. Industries mein is relation ko use karke decision liye jate hai.

    • @pramitapsatapathy5037
      @pramitapsatapathy5037 3 года назад

      @@electricalwithabhishekjoshi
      Sir, will you please kindly technically explain this derivation concept ??

  • @ASHOKSHARMA-nl1zx
    @ASHOKSHARMA-nl1zx 3 года назад

    Sar sar yadi motor co star delta se star mein convert karenge to RPM to koi fark padega kya

  • @sunilkumarbehera8012
    @sunilkumarbehera8012 3 года назад

    Nice sir

  • @surajbhosale8707
    @surajbhosale8707 2 года назад

    How to contact u sir?
    Brilliant information sir

  • @sandeepverma8091
    @sandeepverma8091 2 года назад

    Delta se star mein convert karenge lakin motor ki speed bhi to kam ho jayegi as compared to speed in delta

  • @SachinKumar-kk7zf
    @SachinKumar-kk7zf 3 года назад

    What is the possible fault if 55hp motor runs on star and on switching to Delta the motor trips the mccb ..please explain

  • @islamknowledge5183
    @islamknowledge5183 Год назад

    Some motor are connect in star and delta how can we make connection

  • @VidyanandPrasad-ue7bo
    @VidyanandPrasad-ue7bo Год назад

    ❤😊

  • @SatishKumar-ic7tt
    @SatishKumar-ic7tt 3 месяца назад

    Hello sir 7.5hp motor bar bar over load delta me hai 9.5amp

  • @shafiqahamad6236
    @shafiqahamad6236 3 года назад +1

    Bhai jab aap ka video khatm hone wala Rahe last mein aap yah bhi Bata dijiye ki interview mein iska jawab Kaise Dena hai please bataiye

  • @anwarhussainansari13
    @anwarhussainansari13 3 года назад

    Aur star connected me neutral milta hai jis de ki hum earthing Kar sake jisse ki Humara aur equipment Ka protection ho sake.

  • @vinodvinodkumar7264
    @vinodvinodkumar7264 3 года назад +1

    How to selection contactor for star delta

  • @rajeshjadhav00
    @rajeshjadhav00 2 года назад

    Sir, how to identify that motor is running at 40% load.
    Can motor draw current less than 57% of rated current in Delta configuration on less load application ?

    • @natural6086
      @natural6086 Год назад +1

      Check full load current of motor and calculate ; full load current of motor means current drawn by motor when motor is running at full load.

    • @RajeevSainielectricals
      @RajeevSainielectricals Год назад

      @@natural6086 ri8

  • @YashKumar-hu1xt
    @YashKumar-hu1xt Год назад

    Windings stay same or different for star and delta ?

  • @harekrushnabehera3518
    @harekrushnabehera3518 2 года назад

    Star connection me current.?
    Delta connection me current..?

  • @bhupendergindran225
    @bhupendergindran225 11 месяцев назад

    Satar Or Delta ke RPM ki jankari

  • @hiteshpatel4317
    @hiteshpatel4317 Год назад

    Filhal company ne delta connection kiya he .