Diagnosing issues in a Home Infrared Sauna

Поделиться
HTML-код
  • Опубликовано: 28 янв 2025

Комментарии • 78

  • @CuriosityCafe
    @CuriosityCafe Год назад +2

    You do a great job explaining all the components. May I ask, I have an Infrared Sauna that just won't heat up. If I turn it on and off a bunch of times once in a while it will. Seems odd. Everything else works, all the lighting, controls, bluetooth sounds. Do you have any idea what could be the cause? I don't have any techs near me to help with this.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  11 месяцев назад

      Hi, It sounds like an issue with the relay, are you able to send a few photos of your unit?
      Service@customsaunas.com.au
      Allan

  • @johngibbins1671
    @johngibbins1671 10 месяцев назад +1

    Hi Great video. I have exactly what you said. I have 240 volts on one side but nothing on the 12 volt side. Do you know where I can get parts as I live in the UK

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  10 месяцев назад

      Hi John, we can ship to you in the UK, or you can get them from a local electronics supplier. The important information is the 'output' voltage, most commonly it is only 12vdc, but very occasionally it is both 12vdc and 5vdc. feel free to send a photo of yours.
      Part: 12vdc 60w 5a Switching Power supply
      Allan Burns - Service@customsaunas.com.au

  • @KimAtwood-z9o
    @KimAtwood-z9o Месяц назад

    Hi great video I have heat in 4 panels ut not in 3 on the same side ut I do have power on that side a y thoughts that is in advance Bill

  • @davidritchie4511
    @davidritchie4511 5 месяцев назад +1

    I have an infrared sauna that fails to start when pushing the power button. The outlet has power, no breakers tripped. My guess is perhaps the fuse needs replacement. I do not have the owner's guide, nor do I recall the brand of the sauna. Sucks to be me, I know. Any suggestions would be greatly appreciated.

  • @daveg2199
    @daveg2199 Месяц назад

    Hi Great channel!! My units 3 back elements work but the two vertical front elements each side of the door do not. No voltage at top block of each side. What does that likely mean?

  • @jmichigan3282
    @jmichigan3282 4 года назад +2

    Thanks.
    A video on how to test and change fuses would be helpful. For example, in a sauna with 2 fuses and 2 relays, only half of the six infrared panels work. How to diagnose the problem? Can I switch the two fuses to see if that reverses which panels don’t work? Or switch the two relays? Thanks for any input.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  4 года назад +2

      Hi J, thanks for your feed back, I am more that happy to do a video on changing other aspects of the Control Box including the Fuses. For me to get a better understanding of your situation are you able to send me a top down photo of the control box. With that I will be able to give you more definitive advice. But ultimately swapping the fuses over should help narrow down the fault. Allan service@customsaunas.com.au

    • @alejandromatias6564
      @alejandromatias6564 Год назад

      @@infraredsaunarepairs5982 hello have a question anyway you can contact me or I contact you

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      @Alejandro Matias please email me on Service@customsaunas.com.au we can communicate through this

  • @AidenKahn-v8l
    @AidenKahn-v8l 5 месяцев назад

    Awesome video!! Thank you for the help. I’m attempting to narrow down the issue of my sauna, but not success.
    My sauna has started to turn itself off and randomly “beep” as if I am pressing the buttons, it even lights up the buttons as I am. Sometimes the buttons don’t work as well. Let me know your thoughts. Thank you so much!

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  5 месяцев назад +1

      You're welcome, are you able to send a few photos? I might recognise the control panel and know if some common faults. The first thing that comes to mind is that when the switching powersupply is failing you can have symptoms like this. Email any photos to service@customsaunas.com.au

  • @habh8r77
    @habh8r77 Год назад

    Love your style of explaining troubleshooting…my issues is the 3 rear ceramic tubes are not working consistently and the 2 front ones work fine. I checked continuity on the fuses and relays. Is this partial functionality a common issue? Thx

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Hi, this can be an issue with the relay in the box in the ceiling. Alternatively you could have just got unlucky and have three failed tubes. Can you send some photos of your unit to my email, I'll take a look and get back to you. Service@customsaunas.com.au
      Allan

  • @gmadawn3902
    @gmadawn3902 2 месяца назад

    We have determined we have two bad ceramic heating elements but we can't seem to find the right size. 660mm 300w/120v and 600 300w/12v (especially the 660mm) any recommendations?

  • @nourishingelements
    @nourishingelements 2 года назад

    I have a 2011 dynamic 3-person sauna from Costco. I was pushing the timer button up very fast and then after I turned the sauna off it won't turn back on. The reset button on the back of the power box is still in and I checked my breaker and it's all good. Could I have just blown a fuse, would the problem be in the power box on top or would it be the control panel? I'm hoping I don't have to replace the whole box. Thanks

  • @terrygolden1105
    @terrygolden1105 Год назад

    I’m considering buying a used HighTech Health sauna but the power flickers when the temperature gets to about 122-125 degrees. Any ideas? Should I not buy it?

  • @nickevans8862
    @nickevans8862 2 года назад +1

    HI, I have a high tech health sauna, and when i try to raise the temperature it shows an "L" on the screen and just beeps. Do you have any idea what that is? Thanks

    • @mildredflores8260
      @mildredflores8260 Год назад

      I have the same brand my panels in the back won’t heat up.

  • @TheVargaGirl
    @TheVargaGirl Год назад

    Is it still okay to use my infrared sauna if there is tiny hole in one of the carbon panels? The sauna still works, but wondering if it needs some type of repair, or is is a fire hazard? Thanks.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Hi, No please disconnect immediately. If the hole is in the heating elements are of the carbon panel it will react with the atmosphere and grow larger to it combusts. Please send photos to Service@customsaunas.com.au I'll take a look and get back to you
      Allan Burns

  • @Liftingdoc
    @Liftingdoc 8 месяцев назад

    Anyway I can ask a question about mine? Just moved into a new house and not sure how to get it working.

  • @timothyyyyyyyyyy
    @timothyyyyyyyyyy 3 года назад

    Good afternoon, how many volts should be going to my keypad controller? my DC-1 Has 12 volts going to my radio and DC-2 has 7 volts going to the controller. When I put the controller on DC-1 the 12 volts it sounds a alarm and the controls light up but won't do anything. Thank You, Tim

  • @meagainandagain5756
    @meagainandagain5756 3 месяца назад

    One set of ceramic heaters don’t work. Must be a series circuit. Testing proved that it wasn’t the fuses. That’s unfortunate since the sauna came with 2 extra fuses, and that would have been easy. I guess I should go through the testing you have instructed in this video, before I test the elements. Your 240 reference likely doesn’t refer to Canada?

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 месяца назад

      Hi, yes, using the same method but testing for 110-120v. I think it'll be the relay in the ceiling or the tube wiring.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 месяца назад

      If you need further assistance please contact us via
      Infraredsaunarepairs.com.au

  • @trevorarmstrong7869
    @trevorarmstrong7869 Год назад

    Any ideas if the board clicks when you turn it on and than resets

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Hi Trevor, it sounds like a relay, possibly one that's switching on the Switching PowerSupply. Can you send a couple of photos?
      Service@customsaunas.com.au

    • @trevorarmstrong7869
      @trevorarmstrong7869 Год назад

      @@infraredsaunarepairs5982 I don’t see how to send pics. Is there an email to send too thanks. Appreciate it.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Service@customsaunas.com.au

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Infraredsaunarepairs.com.au

  • @brucedorworth6189
    @brucedorworth6189 2 года назад

    I have a Infared LuxSauna, not sure where to find the serial number. The lights on the front panel are blinking and pressing the button on panel have no response.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  2 года назад

      Hi Bruce, that's probably a low voltage switching powersupply, when they start to fail the voltage can fluctuate causing odd things to happen on the controls
      This is the likely part
      infraredsaunarepairs.com.au/infrared-sauna-parts/switching-transformer-12vdc-60w-5a

    • @brucedorworth6189
      @brucedorworth6189 2 года назад

      @@infraredsaunarepairs5982 Thanks, I checked all the voltages on the transformer/power supply.
      , and they seemed correct. I ordered a new ps anyway it should be here tomorrow. I did more checking today and found out that I am not getting any voltage through the switching relay. I am not getting any voltage to open relay. When I unplugged the relay switch control wires from the control board it stopped blinking. I am ordering two new switching relays today. To be continued...

  • @msv9637
    @msv9637 Год назад

    My infrared sauna is only using one heater to heat up then after 30-40 minutes or so the 2 back heaters turn on (not all the time) but two others never do. So sometimes my sauna will heat all the way up with added time and other times it just stays at 39 Celsius. Not sure what would cause the heaters to not turn on but sometimes only some do turn on while one it seems to be the soul constant working one. Any ideas?
    It’s a 2 person sunhealth

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Can you send me a few photos of your unit? Heaters and the wall controller. Could be a few things, I'll let you know what I think once I see them. Please email them to Service@customsaunas.com.au
      Allan Burns

    • @msv9637
      @msv9637 Год назад

      @@infraredsaunarepairs5982 ok. Thank you. I’ll do that asap.

    • @msv9637
      @msv9637 Год назад

      @@infraredsaunarepairs5982 ok. I sent 3 photos to that email. Let me know if you got them & if you need anymore. Thank you. I really appreciate you taking your time to try to help me

    • @msv9637
      @msv9637 Год назад

      @@infraredsaunarepairs5982 if it matters, although it’s always been on a surge protector, it did seem to happen after several blackouts

    • @msv9637
      @msv9637 Год назад

      @@infraredsaunarepairs5982 not sure if you got my email but I have new info that may help you help me diagnose this issue.
      Almost all the heaters started working today and then the unit tripped the surge protector

  • @2008topshelf
    @2008topshelf 2 года назад +3

    Has anyone else seen their sauna stop working when they've not even used it except for the internal light and/or the internal radio? Perhaps with a few unplanned power outages over a calendar year?

    • @alexrojo1685
      @alexrojo1685 2 года назад

      exact thing happened to me. it turns on then shuts off right away.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      This is most likely an issue with the Switching PowerSupply, it'll get a little boost as it's turned on, then the voltage will drop

  • @brandymartinezlopez6714
    @brandymartinezlopez6714 Год назад

    My control panels wires came out and I don’t know the order to rewrite them.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Hi Brandy, can you please send me a few photos of the control system and the wiring, I might have seen it and have a wiring diagram. Send to service@customsaunas.com.au
      Allan

  • @Fullsendit_ENT
    @Fullsendit_ENT 3 года назад

    I have a i feted sauna 3 of the 6 back panels not working can you help ?
    Only reaching 46 degree is this high enough

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 года назад

      Hi K Bee, we can certainly try to help you, are you able to send a couple of photos to my email so I know what Sauna we are talking about?
      Service@customsaunas.com.au

    • @Fullsendit_ENT
      @Fullsendit_ENT 3 года назад

      @@infraredsaunarepairs5982 thank you kindly I’ll shoot a email off

  • @bigg797
    @bigg797 2 года назад

    Hi enjoyed your video and learned alot thank you and I found fault in isolator swich so can you please tell me where I purchase Ia new isolator swich from thank you Geoff

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  2 года назад

      Hi Geoff, glad it was helpful.
      Those switches can be purchased from an electronics store like Jaycar just make sure that it has at least a 16amp current rating. Alternatively because you can unplug the unit the switch can be permanently remove.
      Allan

  • @tocolee6127
    @tocolee6127 Год назад

    My sauna heats up perfectly but the control panels int./ext. blink off and on constantly! Help?!

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Hi, are you able to send through a couple of photos of the control panel, If I can work out the model, I might be able to isolate some common faults they have.
      Service@customsaunas.com.au

  • @therealkerri1159
    @therealkerri1159 4 года назад

    We have a lux sauna 4 person sauna we have a problem and need diagnosing

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  4 года назад

      Hi K B, I'm sure we can help. Are you able to send some photos of the sauna, wall controller and the box in the ceiling along with a description of the symptoms to my email, service@customsaunas.com.au

  • @meow6185
    @meow6185 3 года назад

    What would cause the sauna to shut off after a few minutes? I’ve used the sauna for a year and it will not stay on now.

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 года назад

      Hi Meow, if the Low Voltage Switching PowerSupply is on the way out this can cause it to work for only a short period of time before needing to be reset, it might be worth checking the Voltage coming from the DC side of the PowerSupply

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 года назад +1

      infraredsaunarepairs.com.au/infrared-sauna-parts/switching-transformer-12vdc-60w-5a

    • @cassiethomas3668
      @cassiethomas3668 2 года назад

      @@infraredsaunarepairs5982 I’m having the same issue in my sunlighten mpulse. Itrued what you suggested but it seems ok. It was fine until we had the sauna on during a power surge. I ordered a new relay but when I tested that on the volt ohm meter it appears to be fine. Any other suggestions? Or maybe I’m doing some wrong?

    • @cassiethomas3668
      @cassiethomas3668 2 года назад

      Sauna comes on but shuts off after maybe 5 mins. The relay that pops the button out is always very hot after it shuts off so I was guessing it was bad but makes me wonder what is making it hot as it is just doing it’s job and shutting down when it gets too hot, right? I’m not electrical savvy but I’m not completely hopeless either 😂

  • @iknowsports6366
    @iknowsports6366 2 года назад

    Hey Tim I have a infrared sauna that’s giving me a E1 and E2 code can you help me

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  2 года назад

      Hi Tim, can you send me some photos of your specific unit, it's likely an issue with the thermostat, either no longer connected or chewed through
      Allan

  • @ericguzman8931
    @ericguzman8931 Год назад

    My unit is brand new but reset pops after 2 min of being plugged in I moved it 3x in my house please help

  • @suegross9878
    @suegross9878 3 года назад

    I was cleaning my sauna and with the floor piece removed 2 wires touched and now my unit doesn't work. can you tell me what I did wrong?

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 года назад +1

      Hi Sue, with any luck all you've done is blown a fuse. In most infrared saunas there is a control box located in the ceiling (or under the bench) these will often have a fuse installed in them between the incoming power and the sauna itself. If you've shorted out two wires this will have caused the fuse to blow. Are you able to reach out via email with a couple of photos so I call help you work through it?
      Service@customsaunas.com.au
      Allan

  • @2008topshelf
    @2008topshelf 2 года назад

    Excellent video!

  • @catorialeon7928
    @catorialeon7928 3 года назад

    Our Infared Sauna turns on and just beeps, what might that mean?

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 года назад +1

      Hi Catoria, that sounds like an error/short circuit in the low voltage control system. Are you able to send a couple of photos of your Sauna to my email so I can identify the model and hopefully expand further? My email is service@customsaunas.com.au

    • @Gagasfave_itsniaa
      @Gagasfave_itsniaa 3 года назад

      @@infraredsaunarepairs5982
      Same problem here..
      HeatWave BSA2406 2-Person Deluxe Ceramic Infrared

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  3 года назад

      @@Gagasfave_itsniaa I'm happy to look into it further with you if you need, just send me through some more details and maybe a photo or two
      Service@customsaunas.com.au

    • @Gagasfave_itsniaa
      @Gagasfave_itsniaa 3 года назад +1

      @@infraredsaunarepairs5982 I got it working. Missed a connection. Thank you

    • @Pj-jz2nr
      @Pj-jz2nr 9 месяцев назад

      Hey mate excellent video… thank you. I have a similar sauna the Thermostat prove corroded and fell from the ceiling and now won’t work. Where can I purchase a new probe/sensor if you can help great?!!!

  • @brickdorsi
    @brickdorsi Год назад

    How to install a relay to make it smart

  • @mildredflores8260
    @mildredflores8260 Год назад

    My back panels aren’t hearing up 😢

    • @infraredsaunarepairs5982
      @infraredsaunarepairs5982  Год назад

      Hi Mildred, can you send me a couple of photos of the unit with the heaters and control panel? There might be a failed individual relay
      Service@customsaunas.com.au

  • @2008topshelf
    @2008topshelf 2 года назад +3

    Let me say that one of fucked up things about these damned corner 400 pound saunas is that, once you assemble them and nail down the roof, you only figure out later the designers put the damned control box in the far corner where no adult > 90 pounds can reach it. So its almost impossible to go through the manufacturers control box test unless you want to fall through the roof. A 3rd grader designer would have put the power supply on one of the two front facing sides which sandwich the door.