  • It's still chilly outside, and the owner of this '01 Chrysler Town and Country has to bundle up for her drive to work...the blower motor quit working.
    Sounds like a perfect case for Pine Hollow Auto Diagnostics!
    In Part 1 I diagnose the issue, and in Part 2 come back to repair the van later that same day. Now that's service!
    Enjoy! :)

Комментарии • 68

  • @joelmccoin9727
    @joelmccoin9727 8 лет назад +4

    Excellent Job!!! This should be an example to all young guys starting out in auto repair....Don't just hang parts. I am always impressed with how complete your diagnostics are. I have said it before, You should be teaching, you are a natural, calm and collected, easy to understand and follow. Thanks Ivan...keep the videos comming

    • @chrisfoxworth3228
      @chrisfoxworth3228 8 дней назад

      I watch that and now have hundreds of questions . When it comes to whipping out papers and diagrams with all that yackity yack im lost.

  • @upallnight888
    @upallnight888 8 лет назад +5

    Great vid, especially on the amp test. Eric O did a similar repair where he just replaced the module and a couple of weeks later the car was back with the same problem. He did the amp test and found that the blower motor was pulling too much current and burning out the module.

  • @craiggoodwin9704
    @craiggoodwin9704 2 года назад

    Ivan, I find myself here because I'm trying to decide if I want to go cheap or actually replace the blower motor. On to Part 2. Thanks for Sharing!

  • @AdrianKingsleyHughes
    @AdrianKingsleyHughes 8 лет назад +6

    "All we're interested in is the wire colors. I hope they're right."
    Auto diagnostician's prayer!

  • @whenjeffgetsbored
    @whenjeffgetsbored 5 лет назад +1

    That was one of the best description of how the system works that I've seen on RUclips. You're a great mechanic and I'm a mechanic as well. Thanks for teaching me how that works I was able to get my system working.

  • @haywardsautomotive6156
    @haywardsautomotive6156 8 лет назад +2

    Nice diagnosis Ivan especially with the blower motor amperage check. Blower motors can run for a long time drawing high amperage so an undiagnosed blower motor starts taking out resistors and modules. I have the same jump pack...it works awesome.

  • @leesteele4574
    @leesteele4574 6 лет назад +1

    Good diagnosis, no parts cannon fired in this video!

  • @pedrolriveranegron5178
    @pedrolriveranegron5178 8 лет назад +1

    Hi my good friend Ivan!!!!! When you put the clamp meter to check amp reading , I remember see a video from our friend Erick-o, which change the module from a town&country but forgot to measure the amperage of the fan! and he had problems after......These things happen and we are not perfect !! but we learn along the way! VERY IMPORTANT; ALWAYS CHECK YOUR AMP READINGS!!!

  • @jgeorges3061
    @jgeorges3061 8 лет назад +1

    good video and info as always big thumb up for finding the amp draw from the blower motor to fix the problem completely and no come back. thanks IVAN, and cheeeeeers.

  • @12volttech5
    @12volttech5 8 лет назад +1

    Very professional diagnosis.

  • @leebarnes655
    @leebarnes655 8 лет назад +2

    Excellent diagnosis, every base was covered, she certainly is getting her money's worth here. Only argument out of me is that an analog voltmeter CAN be used to see pulse modulated signals with but the verus is still sexy eye candy in comparison. In that use we don't know what the proper voltages are unless we have a 'known good' example to go by, but we could still see the voltage go up and down with the control knob.

    • @PineHollowAutoDiagnostics
      @PineHollowAutoDiagnostics  8 лет назад +1

      +Lee Barnes Analog voltmeter...wow don't know the last time I saw one of those in action. But that would be a great tool to use in this case to look at the duty cycle control wire for sure!

    • @lorrinbarth1969
      @lorrinbarth1969 8 лет назад +1

      +motoYam82 I had an analog meter I bought on clearance at Radio Shack and used it for years for automotive diagnosis. Then one day I slammed the hood on it. So, time to move up to a fancy Fluke. I hate it but I use it. Is that a reading or is it? The needle movement contained a lot of information that is now lost.

    • @leebarnes655
      @leebarnes655 8 лет назад +2

      +Lorrin Barth Semper fi old soldier. I used mine to read 1/2 ohm for determining shorted glow plugs from still good glow plugs and used up all the still good ones on those international diesels sold in Fords going back quite a while now. DVM alone can't begin to do this - there is no other stand alone tool that really can. This was also a Radio Shack $20 unit, but sadly they don't have them anymore or I would buy several right now. Last batch I saw anywhere were tiny toy imports and very lousy, but still better than a DVM at times.

    • @PineHollowAutoDiagnostics
      @PineHollowAutoDiagnostics  8 лет назад +1

      +Lorrin Barth Yes there is something to be said for analog needle-type instruments. For example a speedometer...I hate the digital readout ones, since you actually have to READ the number; glancing at a needle gives you more of a "ballpark" reading, which is all you really need in most situations.

  • @acarl-lo5tg
    @acarl-lo5tg 8 лет назад +3

    Ivan does a great job of performing as "super sleuth" and gets to the root of the problem. I noticed that the 2 wires to the fan motor do not match in color to those shown on the wiring diagram. The diagram has blue / yellow tracer and dark blue but in the video you see green and black. This is probably a color change update that missed the documentation update.
    The current draw on the fan motor at high speed indicates 25 amp which does seem high at first glance. However if you look closely at the wiring diagram, fuse 10 in the IPM (intelligent power module) is rated at 40 amp. Hmmm. So maybe 25 amp draw on the front blower motor at high speed is within design limits.
    I am thinking that in part 2 Ivan is going to give a surprise diagnosis or gotcha! Year 2001 was the first year that Chrysler incorporated a cabin air filter inside its climate control plenum box. My theory is that the amp current draw by the blower motor is NOT the cause of the problem. The cabin air filter is plugged such that there is limited air flow. With less air flow across the power module heat sinks that protrude into the plenum box, it overheated and failed??? Anxiously awaiting part 2.

  • @William100-t2z
    @William100-t2z 8 лет назад +5

    Ivan, how did you come to the conclusion the blower motor was using to many amps. Did you use the rule of thumb, motor amps should be less than half the supply fuse rating or have you another quick way to confirm it.Thanks.

  • @baxrok2.
    @baxrok2. 8 лет назад +1

    Outstanding job Ivan. Good to hear you talk about doing the job right and thoroughly. This would have been a great application for the uScope. Thinking about getting one myself.

    • @PineHollowAutoDiagnostics
      @PineHollowAutoDiagnostics  8 лет назад

      +Baxrok2 Thanks! The UScope is kinda cute, I was thinking of buying one. But a scope really needs at least two channels. I think a used Vantage 2-channel graphing meter would be much more useful!

  • @fieldsofomagh
    @fieldsofomagh 8 лет назад +2

    Ya haven't forgot the basics.Nice one checking the current flow.

  • @johnr423
    @johnr423 6 лет назад +1

    Good video ! You have a good grasp on electrical systems ! I hope to get there one day myself

  • @TheGibby3340
    @TheGibby3340 8 лет назад +1

    Hmmm....As you pointed out during your testing 90% duty cycle being the max would take the motor current down to around 23.5 amps... Is that excessive on a 40 amp feed ? I guess we'll find out in part 2. Very sensible troubleshooting , nice.

  • @keithkennedy9065
    @keithkennedy9065 8 лет назад +1

    cool videos ivan.. you and eric are a great team and are great at explaining the process.

  • @wysetech2000
    @wysetech2000 8 лет назад

    Nice, thorough diagnosis, Ivan.

  • @rainman2276
    @rainman2276 4 года назад +1

    What brand of jumper is that and where do I get one. Great video. Thanks Mac

  • @SteveRobReviews
    @SteveRobReviews 8 лет назад

    Fancy foot camera action there buddy. Top notch !!

  • @cobraninetysix3883
    @cobraninetysix3883 7 лет назад +1

    Nice demonstration. Where can one find amp specs for a component that is being tested?

  • @JVerschueren
    @JVerschueren 7 лет назад +1

    Strange... you should have got a variable reading off the PWM control signal using the multimeter, given it's basically a re-branded Extech EX730. The signal appears to be about 40Hz, so I don't understand why the RMS converter failed to integrate it.
    I should have seen this vid while still working at my previous job, I could have replicated the signal with an AFG and checked what different multimeters made of it. That would have been a fun thing to demo (both when attempting to flog a multimeter or an AFG ;-)).

  • @jaironunez2210
    @jaironunez2210 5 лет назад

    Excellent video, thanks for your time

  • @zoidberg444
    @zoidberg444 8 лет назад +1

    Nice of Chrysler to put it there. Very unlike them really...
    Interesting diagnosis. I would have thought your DMM would have been able to give you the frequency of the modules output. Nice to have the fancy snapon scope though. I'm thinking of getting a cheap scope for some of my electronics projects. Lots of stuff is PWM these days.

    • @TheLifeOfMartin
      @TheLifeOfMartin 5 лет назад

      I did the heads on these and it was maybe the easiest head job I have ever done in my live besides one exhaust bolt. One of the easiest in most things to work on so far

  • @squareyes1981
    @squareyes1981 8 лет назад +1

    Forgive my ignorance but is it normal for a failing motor to draw extra current? Did the failing motor harm the module?

    • @leebarnes655
      @leebarnes655 8 лет назад +1

      +Ian O'Riordan Yes it is typical for worn out motors to do that and yes it did kill the module. Going further, I've seen a stuck motor left on but not blowing then kill blower motor resistor packs on much older equipment that only had old school switches for low, medium and high. It even killed high because for safety, power went thru the resistor pack but only thru the thermal safety fuse part of it.

    • @squareyes1981
      @squareyes1981 8 лет назад

      Brilliant. Thanks for the information.

  • @PawelG-fu4zb
    @PawelG-fu4zb Год назад

    Brilliant video mate

  • @EZRider1979
    @EZRider1979 8 лет назад

    26 amps! Great Scott!

  • @daniemurphy7681
    @daniemurphy7681 8 лет назад

    Ivan, do you have a link to the video describing the verus voltage discrepancy? Great video as always.

  • @tadhoward294
    @tadhoward294 4 года назад

    Excellent video thank you for the passing this on. Got to beleive you'll do well.

  • @02lowrider62
    @02lowrider62 8 лет назад +1

    Very high failure rate on them, make sure you check harness too, don't bother putting in aftermarket resister wont last, oem is not much more! good video

    • @PineHollowAutoDiagnostics
      @PineHollowAutoDiagnostics  8 лет назад +1

      +02lowrider62 Actually OEM from Chrysler dealer was $20 CHEAPER than a crappy one from Advance Auto...go figure lol

  • @dezblyan5125
    @dezblyan5125 8 лет назад +1

    makes sense good stuff learning lots from ivan

  • @chungaleta1234
    @chungaleta1234 8 лет назад

    Great vid, looking forward to the repair,
    And changing the topic, what camera do you use for these videos? It seems to be a big big on the reflections and yet you handle it with ease.

  • @ericcorse
    @ericcorse 8 лет назад

    Good concise and informative video.

  • @jstutz101
    @jstutz101 8 лет назад +1

    one thing you and Eric O's channel have in common is plenty of Chrysler vehicles.

  • @TheToadkicker
    @TheToadkicker 8 лет назад

    Blower motors suck in those. For some reason the labor time is wrong in 01. Check out the labor guide times for 01 and then for 02 & newer. It is the same procedure, but you can sneak them out. Just make sure all the plastic is warm

  • @dcrickerson9775
    @dcrickerson9775 8 лет назад

    Very nice work!

  • @MommaBearsCorner
    @MommaBearsCorner 4 года назад

    i think i might cry now... lol thanks for sharing... if thats it, might try it, might not, but at least i know what someone would have to do so i know whats going on.. thanks

  • @kokomokid4006
    @kokomokid4006 2 года назад

    LOVE YOU GUYS!✌👽🍺
    P.S...your so right

  • @1kevinroberts
    @1kevinroberts 4 года назад

    heavens thank tyou for an intelligent video.

  • @eddiemartinez265
    @eddiemartinez265 8 лет назад

    Hey ivan good job!

  • @noegonzalez4050
    @noegonzalez4050 11 месяцев назад

    Hi thank you for your video I 👍🙏

  • @georgekonrad911
    @georgekonrad911 8 лет назад

    If you use a led test light would the pulse width modulation make it change brightness

    • @PineHollowAutoDiagnostics
      @PineHollowAutoDiagnostics  8 лет назад

      +George Konrad Great question! Depends on the internal impedance of the PWM control circuit vs. the LED test light. My guess is that it would work!

  • @herculeshunter1352
    @herculeshunter1352 3 года назад

    Why not start with just testing the blower motor?

  • @jasonc.4683
    @jasonc.4683 6 лет назад +1

    I don't know about u. But ur connections be looking all crazy looking. Pretty sure people feel the same way. Are there videos how h learned to make the gadgets

  • @AdrianKingsleyHughes
    @AdrianKingsleyHughes 8 лет назад

    Hahahahahahahaha dat battery has a Christmas tree growing on the terminal!!!

  • @sixpacksandsrts9122
    @sixpacksandsrts9122 8 лет назад

    Sup ?? Yea you did. Keep up the great vids. :)

  • @thewanderingisraelite
    @thewanderingisraelite Год назад

    Within the first 4 minutes you should have just changed out the module and then be done with it.., so what if the thing burns out in 5 years..

  • @jackburner8107
    @jackburner8107 8 лет назад

    sounds alot like chris fix??

  • @neilm8263
    @neilm8263 8 лет назад

    Great vid cheers:)

  • @mikeg3757
    @mikeg3757 8 лет назад +1

    hi Ivan I would assume 99% of your viewers don't have a snapon fancy scope/meter to use. Is there a way to test the control with a DVOM ? thx

    • @bobweiss8682
      @bobweiss8682 8 лет назад

      +mike gal In short, no.
      The other option would be a high end DMM that has a duty cycle feature, but those are less common than a simple scope.

  • @gbowne1
    @gbowne1 8 лет назад

    Yea that battery is one of the worst i seen yet!! get that thing outta there.. new terminals and cables too

  • @treenopie
    @treenopie 6 лет назад

    12:04 Blower Motor test

  • @francoisgraham9793
    @francoisgraham9793 9 месяцев назад

    Bunch of unnecessary explaning about nothing. Get straight to the point. Video was a waste of my time. I watch another video and they explain it in 5 minutes.