kia yeh 3 phase unbalanced load pe b kaam kary ga. suppose aik phase pe 2kw load hai 2nd phase pe 3kw aur 3rd phase pe 5kw load hai to is soorat main kia ho ga.
I have 3kw Growatt inverter (On-grid) installed recently. I can monitor only the power generation from solar, but cannot see the KW consumption of house, Grid import/export data. Is it possible to view that information in Shine App using this device?
Sir, PLEASE kindly look into my matter, I have installed 3kw ON GRID residential Solar system with zero export device, i have single phase meter connection in my home, But i am facing a problem, the problem is that despite having zero export device my solar system is producing more than my home running load and the extra power solar is producing, it is taking from the METER( that is from the grid), But when i increase the load according to the solar power production then it doesn't not take from METER and when i further increase the load more than the solar power production then only it takes EXTRA load from the METER, SO Please tell me sir why it is taking power from METER when it is producing more than the RUNNING LOAD? and why it is producing more than the RUNNING LOAD? And the extra power more than the load produced by the Solar system is showing in NEGATIVE (ex- Minus 600 watt, minus 1000 watt like this) in the ZERO EXPORT DEVICE and the same it is taking from the GRID METER. Kindly resolve my issue sir....i will be very thankful to you 🙏
I got about 75 meter distance to the Hybrid Growatt, which is a to long distance for RS485. Is there a wifi-Option or a way to connect the smart meter over a long distance?
@MB SOLAR ENERGY Pakistan. Salaam brother I am using Growatt spf 5000 es 48v 5kw battery and Canadian 3000 watt panel. Question: My Hybrid system exporting power to grid, can you please tell me how to disable this function?
Hello, I have the same Growatt 30000 TL3-S inverter and Eastron SDM630-Modbus V3 smart meter. I can only monitor solar power generation, but can't see home KW consumption, grid import/export data. Please can you help me what I need to set up
Export limitation is possible without growatt eastron zero export device. I have Growatt MOD 15ktl model. So how can i limit export without zero export device??
kia yeh 3 phase unbalanced load pe b kaam kary ga. suppose aik phase pe 2kw load hai 2nd phase pe 3kw aur 3rd phase pe 5kw load hai to is soorat main kia ho ga.
Great video. Do all SDM630 v3s come with built in CT?
I have 3kw Growatt inverter (On-grid) installed recently.
I can monitor only the power generation from solar, but cannot see the KW consumption of house, Grid import/export data.
Is it possible to view that information in Shine App using this device?
Sir, PLEASE kindly look into my matter,
I have installed 3kw ON GRID residential Solar system with zero export device, i have single phase meter connection in my home,
But i am facing a problem, the problem is that despite having zero export device my solar system is producing more than my home running load and the extra power solar is producing, it is taking from the METER( that is from the grid),
But when i increase the load according to the solar power production then it doesn't not take from METER and when i further increase the load more than the solar power production then only it takes EXTRA load from the METER,
SO Please tell me sir why it is taking power from METER when it is producing more than the RUNNING LOAD? and
why it is producing more than the RUNNING LOAD?
And
the extra power more than the load produced by the Solar system is showing in NEGATIVE (ex- Minus 600 watt, minus 1000 watt like this) in the ZERO EXPORT DEVICE and the same it is taking from the GRID METER.
Kindly resolve my issue sir....i will be very thankful to you 🙏
I got about 75 meter distance to the Hybrid Growatt, which is a to long distance for RS485. Is there a wifi-Option or a way to connect the smart meter over a long distance?
wifi method is more complicated. 75 meter should be no issue.
Hello, is the same possible with SDM630 v2 ?
Thanks
Yes
@MB SOLAR ENERGY Pakistan.
Salaam brother I am using Growatt spf 5000 es 48v 5kw battery and Canadian 3000 watt panel.
Question: My Hybrid system exporting power to grid, can you please tell me how to disable this function?
Does the same way of configuration for MAX series???
Hello, I have the same Growatt 30000 TL3-S inverter and Eastron SDM630-Modbus V3 smart meter.
I can only monitor solar power generation, but can't see home KW consumption, grid import/export data.
Please can you help me what I need to set up
Export limitation is possible without growatt eastron zero export device. I have Growatt MOD 15ktl model. So how can i limit export without zero export device??
I have Growatt 5000MTL-S but I not see RS485. Where I can find this inside of inverter?
Hi sir.
Your shinephone app not asking password for changing parameters, why?
MB Solar please explain the method of zero export activation of Growatt MOD-10kw.
Thanks.....!
same method, only difference is monitoring interface. in MOD you have select "ENABLE METER" in export limitation section.
@@mbsolarenergy thank you from Poland
@@mbsolarenergycan i speak u
What SMD model should i use if I installed 80KW inverter? thanks you
@@travelpakistan4675 Thanks you
is it the same device compitable with MOD KTL-3 Series?????
Yes, it's compatible
Can we Connect this Device with Solis On-Grid Inverter?
How much Does it cost?
we are not sure, however we think it should work with any good brand with proper settings. for prices call us at 03377775521-22-23
Can i use CT directly in MIC Model ?
They removed the CT clamp option so probably won't work anymore. You have to buy the smart meter to do it now.
Which model smart meter use with ct sdm630m ct ?
any eastron meter with RS485 comm will work
Sir please solax ki bhi btadien
Is there a way we can see the meter readings on the app?
only in hybrid models and new X series models. old ongrid models donot support meter data. Contact MB SOLAR ENERGY for growatt latest models
hello, can you say wich is the default "Key Code"
I have need zero export for grow watt with CT
Reactive power settings ?
is this compatible with 20ktl3-x??/
Yes sir. We have latest model compatible with 20KTL series
Call us for purchase and installation
03377775522
03377775530
i need help of you
bhai ismein password konsa input krna hota hai
WaAlaikum Salaam .. Can youvturn on the English subtitle translation pls brother
Yes, we will add subtitles or english version soon
what could I do (to solve…)?
inverter growatt Show
error warning 111
what mean warning 111
111 means smart meter is not working properly
Price
S 3000???
can you explain please
Mera inverter setting per password nahe le raha
Please help
Error in password used default password 12345678 also tried my registration password