Growatt Min-series inverters export limit setup tutorial

Поделиться
HTML-код
  • Опубликовано: 6 фев 2025
  • Growatt Min-series inverters export limit setup tutorial

Комментарии • 41

  • @hamzahansari6900
    @hamzahansari6900 7 месяцев назад

    So at 0% it will not export any energy right even if there is no ct? Means can i set it at 0% without connecting the ct?

  •  Год назад

    Do you know if a three phase inverter can do zero export and load balancing? For example to push all it's capacity to one phase if needed?!

  • @marctheunissen123
    @marctheunissen123 5 месяцев назад

    There is an export limit option on 'enable meter' as opposed to 'enable CT meter'. I would like to have some info on that function, as the homeowner is not going to install a CT meter but I am the one paying for electricity I am putting into the grid ;-)
    Do you have a separate video, or could you provide some info? The specific thing I am looking at, if I enable export limit via 'enable meter', whatever I seem to fill in, the system seems to be shutting down. Right now the system is generating 1300w, of which 1100 are fed into the grid, I have a MIN3600TL-XH, when I set export limit to 50%, my net use (taking from grid) goes toward 100W
    I would expect either of 2 thing to happen: system goes on half power, generating only 650, and I would still be net feeding into grid. OR nothing would happen as 1300 is stil below 50% of capacity. But I got both wrong...
    Thank you!

  • @blainecelestaine4543
    @blainecelestaine4543 2 года назад +1

    Does the 100% setting represent 100%of what the ct is reading the building is calling for or 100%of total inverter capacity? Does the meter support CT on line 1 & 2 simultaneously?

    • @growattaustralia1112
      @growattaustralia1112  2 года назад +1

      100% export represents the inverter's capacity, for example, for a 5kw inverter, if set 100% export, then the maximum output to grid is 5KW

    • @grahamporter5501
      @grahamporter5501 Год назад +5

      @@growattaustralia1112 Why then would you have an export limit set if you are sending all available spare energy to grid? If you want to prevent any being sent to grid, would the setting be 0.00%

  • @jaya8948
    @jaya8948 3 месяца назад

    Do you have any video clips of how to install SPM-CT-E (SDM 120CT) smart metre ?

  • @Vinay97288
    @Vinay97288 2 года назад +2

    Hi team! I am from India and have growatt tlx 3300 tl model Can I use this SDM120 ct meter with the above said model? Also what kind of CT can be used for the same? Please guide as much as you can. Thank you 🙏

    • @growattaustralia1112
      @growattaustralia1112  2 года назад +1

      Hi Vinay, please contact the Growatt Indian support team on 1800 120 600 600 or indiacoordinator@growatt.com(Service)

    • @evm6177
      @evm6177 Год назад

      ​​@@growattaustralia1112 Hi why can't I find 'exported power' data on my Shinephone app? Is there a restriction I need to know about?

  • @cdsilva7555
    @cdsilva7555 Год назад

    Hi, does this inverter have the ability to be set to import at certain times in the night and export at other times in the day.

    • @growattaustralia1112
      @growattaustralia1112  Год назад

      Hi cdsilva, the inverter will automatically import/export based on the load consumption and solar generation, you cannot control the times, sorry for the inconvenience.

  • @haimuoinamtinhcu
    @haimuoinamtinhcu Год назад

    Hi brother? Is there anyway that you can make a video show us how to read this inverter screen ? Thank you

  • @tahirakram9852
    @tahirakram9852 7 месяцев назад

    If export set to zero and there no power supply on day time, in that case will it generate power or it will shutdown?

  • @TylerTheCompiler
    @TylerTheCompiler Год назад

    can you use CT's on the MIN 6000TL-X? Aslo, can you change the CT's ratio if you buy aftermarket CT's? and one more, do you know anyone who has used 0% to see if there will be absolutely zero grid feed? Many utilities now say no grid feed or you pay as if you were using power...

    • @growattaustralia1112
      @growattaustralia1112  Год назад +1

      Hi Tyler, thanks for your comment. For Min 6K TL-X inverter, a meter is required for the export limit control, you cannot only use CT to do so. The recommended meter is Eastron SDM 120. The export limit percentages refer to the energy that is allowed to export to the ac grid, if you set it to 0%, then there will be no power exported to the AC grid.

    • @hamzahansari6900
      @hamzahansari6900 7 месяцев назад

      @@growattaustralia1112 Can i set it at 0% without connecting the CT for the single phase 5kw version?

  • @JimStephanoff
    @JimStephanoff 2 года назад

    Hello. Thanks for the Great instructions I have an MIN 10000TL-XH-US that I would like to add SDM120 ct meters to. In my setup, my Inverter is 50' away from my Service panel. What is the MAX length of cable I can use. Thanks.

    • @shenmisheshou7002
      @shenmisheshou7002 2 года назад

      Did you ever get an answer for this? Thanks!

    • @growattaustralia1112
      @growattaustralia1112  Год назад

      The long distance may interfere the communication between the inverter and meter, there is a communication cable comes with the SDM 120 meter.

    • @bramcoteelectrical1088
      @bramcoteelectrical1088 Год назад

      maximum permissible length between a RS-485 driver and receiver is 4000ft (or 1200 meters). However, both cable quality and data rates impact this distance. As data rates increase, the signal is increasingly attenuated by the parasitic RC- filter created by the cable.

  • @jameswebb5133
    @jameswebb5133 2 года назад

    If I want zero export to grid, can't I leave the export limit on off?

  • @z3nogaming329
    @z3nogaming329 2 года назад

    For 0 export in the greed i Need 100% limit or 0% limite?

  • @JM-yx1lm
    @JM-yx1lm 2 года назад +2

    Why would somebody want to export the limit?

    • @FrankBaker78
      @FrankBaker78 2 года назад +5

      Because in Germany there is a law, that you are not allowed to put unlimitid power to the grid!

    • @SoLuna137
      @SoLuna137 Год назад +2

      In our country, it will be considered as charge if you happen to export power to the grid, when you have not applied for net metering

  • @racataiangheorghe128
    @racataiangheorghe128 Год назад

    Hi, I have Growatt inverter MOD 10ktl3-xh working in my house with the injection limitation set to ON but I am injecting in the grid aprox 40% of the produced energy. Does anybody know what could be the issue? I read that some models of Growatt invertors have an issue

    • @jakupmaksuti5276
      @jakupmaksuti5276 7 месяцев назад

      I have same problem. Do you find a solution?

    • @racataiangheorghe128
      @racataiangheorghe128 7 месяцев назад

      @@jakupmaksuti5276 hi, I meanwhile got the permit to inject in the grid so I no longer have the problem but I also did not get an explanation. I noticed that growatt invertor is not reporting accuratelly

  • @sivamsolar4590
    @sivamsolar4590 2 года назад

    CT RATIO AND CLASS DETAILS

  • @markuslorch9397
    @markuslorch9397 2 года назад

    Es wäre schön wenn so etwas mal auf deutsch käme

  • @leventuslu3086
    @leventuslu3086 2 года назад

    Hello
    I bought growatt 3000 TL -x.
    Is it possible to connect a battery or not?
    There is no battery outlet at the bottom

    • @growattaustralia1112
      @growattaustralia1112  2 года назад

      Hi, you cannot connect a battery to your inverter as it is not a hybrid inverter. For battery compatible inverters, please refer Growatt XH series or SPH series inverters.

  • @MdSojib-xc6rj
    @MdSojib-xc6rj 2 года назад

    M

  • @hrenes
    @hrenes Год назад

    bad sound quality/background noise, hard to understand, what is the problem/why limit export? no bill of material, no scematics.